  • Gross Alignment Funnel / Enhanced Latch Indicator (GAF/ELI)

    Teledyne Marine ODI

    ​A wet-mate connector system designed to optimize ROV mating efficiency, the Gross Alignment Funnel (GAF) can be used in conjunction with the Enhanced Latching Indicator (ELI) to overcome severe approach angles of ROV connectors during mating. In conditions with low visibility and heavy current, the system aids in aligning the mating halves and providing a clear visual indicator when a successful mate occurs. Easily installed on an existing Nautilus or Rolling Seal bulkhead mounted connector, the system reduces ROV operator variability, resulting in faster mating and demating operations.

  • Handheld Gauge for Nondestructive Coating Thickness Measurement

    PHASCOPE PMP10 - Helmut Fischer AG

    Handheld gauge for rapid and precise coating thickness measurement according to the phase sensitive eddy current method DIN EN ISO 21968Copper thickness measurement on pc-boards (probe ESD20Cu with 60 kHz or 240 kHz)Copper plating in through-holes of pc-boards (probe ESL080)Thickness measurement of metallic coatings on ferrous, non-ferrous metallic or electrically non-conductive partsDelivery with PC software FISCHER DataCenter with the following functionality: Transferring and archiving measurement data, comprehensive statistical and graphical evaluations, easy creation and printing of inspection reports

  • High-Voltage LXI Matrix Modules

    Pickering Interfaces Ltd.

    2-pole 75x4 matrix modules with one, two or three separate 75x4 matrices housed in the same case (model 60-311) . Capable of cold switching 750VDC continuous with a carry current of 2A plus higher pulse conditions e.g. typically 1000VDC for 1s with low duty cycle or 6A for 200us with <1% Duty Cycle. Front panel Loop-Thru connections allow a 75x4 matrix to be easily expanded to an adjacent matrix in the same case. Also, expansion can be carried out between 60-311 matrices in separate cases.

  • Inline DC Panel Meter Kit

    SparkFun Electronics

    The Inline DC Panel Meter Kit has all the bits you need to create an elegant, seamless DC volt/ameter. Measuring current usually means interrupting the VCC or ground return path, and 'interrupting' usually means cutting. We designed the kit to be used 'inline' - no need to cut wires just plug your wall wart into the kit and the kit into your target device. We found it to be really handy to measure various 12V devices (routers, WiFi APs, etc) up to 10 amps.

  • IP Solution

    eMMC 5.1 - Arasan Chip Systems, Inc.

    Demand for mobile content capacity and bandwidth for video, pictures and music is ever increasing. To address this demand in the next generation of smartphones, tablets, and portable devices, the eMMC 5.1 Specification from JEDEC, improves the current HS400 speeds operating at 3.2Gbps, with "command queuing" making the data transfers highly efficient by offloading the software overhead into the controller. eMMC 5.1 further improves the reliability of operation by utilizing an "enhanced strobe" at the PHY layer. The eMMC5.1 is backward compatible with the existing eMMC 4.51 and eMMC 5.0 Devices.

  • K-Band Waveguide Gunn Oscillator Module

    FMWGN1001 - Fairview Microwave Inc.

    FMWGN1001 is a K Band Waveguide Gunn Oscillator with a Center Frequency of 24.125 GHz and a Tuning Range of +/- 1.0 GHz. The unit has a Phase Noise @ 100kHz Offset of -95 dBc/Hz typ and Frequency Stability of -0.4 MHz/°C max. The Gun Oscillator has an Output Power of 10 dBm min and Power Stability of -0.04 dB/°C max. The Waveguide Gun Oscillator uses a Bias Voltage of 5.0 Volts and a Bias Current of 200 mA and has a Waveguide Size of WR-42 with a UG-595/U Flange.

  • QuadStat

    EA164 - eDAQ Pty Ltd.

    The QuadStat is a software-controlled four-channel potentiostat. Each channel can be used as a single three-electrode potentiostat. Alternatively two (bipotentiostat), three, or four working electrodes can be used in a single reaction chamber with a common reference and auxiliary electrode. Potential at each working electrode can be independently adjusted between 2.5 V, or by using an external waveform generator to between 10 V. The QuadStat can measure currents from pico- to milliamperes, making it ideal for amperometric biosensor research including use as a multichannel monitor for in vivo nitric oxide or dissolved oxgen sensors.

  • Triple Channels DC power supply

    IT6300 Series - I-TECH Electronic Co., Ltd

    IT6300 series is high-performance programmable triple channels DC power supply, each output voltage and current can be setfrom0 tomaximum rated output.This series provides series connection, parallelconnectionand synchronous functions ofchannel, which offer multi-purpose solutions forcustomerstest.IT6300 seriesis with high resolution1mV / 1mAand remote sense function,  which make the test more accurate. Withbuilt-in standard USB / RS232 / GPIB communication interface,IT6300 seriesgreatly enhance the communication speed, and customersalsocanadjust the digital step value byusing the cursorto  to facilitate the operation.

  • DC 600A Clamp Meter,Auto range

    ST-600 - KILTER ELECTRONIC CO.,LTD

    Measuring Range: 0 - 600A DCDisplay: 6000 countsAuto range: 60A/600AResolution: 10 mA in 60A range 100 mA in 600A rangeBasic Accuracy with Conductor Central in Jaws: ±1.3% rdg ±1 digitEarth Magnetic influence: ±10mA @50mA in 60 A range (not Including zero offset)Temperature coefficient: 0.2%of rdg /°CFrequency range: DC current onlyOverload capacity : 10,000AMax jaw Opening: 35mm maxPower Supply: 9V alkaline batteryDimensions: 196mm(L)× 71mm(W)× 33mm(H)Weight: 184g

  • Precision I/V Source

    MeasureReady™ 155 - Lake Shore Cryotronics, Inc.

    The MeasureReady™ 155 Precision I/V source combines premium performance with unprecedented simplicity for materials scientists and engineers requiring a precise source of current and voltage. Low RMS noise: from 200 nV (10 mV)/7 pA (1 µA). Bipolar, 4-quadrant power source. DC and AC modes supported up to 100 kHz*. Full scale ranges from 10 mV to 100 V (1 μA to 100 mA). 0.001% programming resolution (from 100 nV/10 pA.

  • 4 High-Voltage/High-Current (External VCC) D/A Outputs

    DA5 - North Atlantic Industries

    Digital-to-Analog (D/A) module DA5 provides 4 independent D/A output channels (half-bridge) utilizing a single external supplied power source with full-scale operating range of 0-65 VDC (V-control mode) and 0-2 A (I-control mode). Alternatively, two channels can be paired (full-bridge) to achieve a full-scale operating range of ±65 V and ±2 A from a single external supplied power source. Linearity/accuracy is ±1% FS range over temperature. The DA5 provides either voltage or current control loop modes, which are programmable for the application.

  • Molded Inductors

    Pulse Electronics

    Molded inductors are constructed by pressing or molding a magnetic material around a pre-wound coil and lead-frame to form the inductor. Our molded inductors provide a fully shielded, high energy density, soft saturation solution for applications up to 110Apk. The construction enables low profile solutions in a cost effective and robust solution that minimizes acoustic noise. We offer a high saturation current series (commercial and automotive, -40C to 125C) and a low DCR series (automotive, -55C to 155C) in a wide range of platforms from 4x4x1.2mm up to 24x24x13mm.

  • Performance Dynamometer

    Mustang Dynamometer

    The MD-250-HD was designed to be a performance dynamometer first, with the added benefit of being able to test 2-wheel-drive heavy-duty vehicles such as truck, buses and commercial vehicles. No other dyno in its class offers more value or better in-house motor vehicle testing capabilities than the Mustang MD-250-HD. For starters, the MD-250-HD can boasts a 1,500 horsepower measurement capacity at a top speed of 175 mph and a powerful air-cooled eddy current brake provides the MD-250-HD with 900-hp worth of loading capacity for steady state testing.

  • Blood Ionized Calcium Pocket Water Quality Meters

    LAQUAtwin Ca-11C - HORIBA, Ltd.

    Milk fever, or Sub Clinical Hypocalcemia (SCH) is a significant problem with dairy cows. Total calcium levels in the cows’ blood drop after lactation. By measuring the ionized calcium levels of the blood directly cow side, the treatment can start sooner and is more effective. The new LAQUAtwin CA-11C has been specially developed for cow side measurement of ionized calcium in blood. Ionized calcium reflects more accurately the current calcemic blood situation compared to total blood calcium as it equals the free available calcium ions.

  • Workhorse Quartermaster

    Teledyne Marine RD Instruments

    RDI's 150 kHz QuarterMaster ADCP has been designed to fill a gap between our 300 kHz Workhorse ADCPs and our 75 kHz Workhorse Long Ranger. This unit offers an extended current profiling range over our higher frequency units, in our proven Long Ranger configuration. The Quartermaster is ideally suited for applications in which you're interested in measuring the top 300 meters of the water column. The highly versatile QuarterMaster can also be upgraded to include our bottom tracking option.