Filter Results By:

Products

Applications

Manufacturers

Showing results: 4501 - 4515 of 5270 items found.

  • TRUE RMS AC Clamp Meter

    2960 CL - Standard Electric Works Co., Ltd

    ● True RMS measurement.● Pocket size.● 4000 counts.● Full automatic measurement. Voltage measurement. Current measurement. Resistor measurement.● Data hold function.● Continuity check.● Diode measurement.● Select function.● Low battery indication.● Auto off function.● Flashlight (Auto off in 1 minute).● Re-power on by pushing any of the push buttons or by changing the rotary switch mode after auto power off.

  • PCB Triaxial Accelerometer, 1000mV/g, ICP®(IEPE), 0.5Hz-3kHz

    784815-01 - NI

    The PCB Miniature Triaxial Accelerometer helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB Miniature Triaxial Accelerometer features a sensitivity range of 1000 mV/g and requires the PCB lightweight cable with 4-socket plugs.

  • HV Test System for Patient Monitors

    LXinstruments GmbH

    HV test enclosure for testing medical products (patient monitors). Insulated test booth with large space for DUT.3 different test nests for adapting different devices.Displays from patient monitors are checked. For this, insulation tests and leakage current measurements must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.

  • Semiconductor Test System

    IST Information Scan Technology, Inc.

    As power modules age, their performance degrades. Proper testing and maintenance of semiconductor devices used in power switching can ensure optimal performance and prevent down-time throughout a device’s lifecycle. The IST Model 8900 Series Discrete Semiconductor Test Systems allows you to effectively identify the percent of degradation in semiconductor devices by simulating the exact current and voltage of the parameters used by devices under real operating conditions.

  • General Purpose Radiation Survey Meter/Geiger Counter

    Rad 100™ - International Medcom

    The RAD 100™ is a general purpose radiation survey meter/geiger counter that detects and measures alpha, beta, gamma, and X-radiation. It is intended for personal safety and educational purposes. Like the popular Radalert® 100X, the RAD 100™ features a 3-second update on its digital liquid crystal display (LCD). The LCD shows the current radiation level in your choice of microSieverts per hour (SI units) or mR/hr for gamma radiation measurements. For mixed sources (alpha, beta, gamma) the CPM mode is recommended. This instrument also offers an accumulated total and timer function, up to 9,999,000 counts and 40 hours. A red LED blinks and a beeper chirps with each count (the chirp can be muted). This is a professional instrument that is also easy to learn to use and to operate, and carries the industry leading Medcom warranty (2 years overall limited to 1 year on the GM sensor). Many instruments designed by the Medcom team are still working perfectly after 30 years of use, so this instrument should provide a lifetime of useful information.

  • Load Cell Amplifier Signal Conditioner with DB9 Connectors

    MODEL LCA-9PC - Transducer Techniques, Inc

    The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Load Cell Amplifier Signal Conditioner with Removeable Terminals

    MODEL LCA-RTC - Transducer Techniques, Inc

    The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Vivarium Rooms

    Darwin Chambers Company

    Darwin Chambers Company ALAAC, OLAW, USDA, and NIH-compliant Vivarium Rooms are designed for maximum value, sustainability, and conformance with applicable standards. We have over a decade of experience in working with researchers to provide humane and often precise conditions to meet their unique and specific needs. Vivariums are commonly defined as a place, such as a in laboratory, where live animals and/or plants are kept under conditions simulating a natural environment. Often, these contain both plants and animals, within a micro-ecosystem, often with controlled stability or controlled change of environmental variables. We offer various surface finishes, including all stainless steel, which are easy to maintain and may be sterilized to cleanroom standards. Compartmentalized enlosures are offered, which are modular and reconfigurable. Our rooms will accommodate plants as needed (we also provide plant growth chambers), and we offer control of humidification in conformance with current ALAAC mandates, sufficient air exchanges, available HEPA filtration of intake and/or exhaust air, standard screened equipment hous- ings, and other such considerations.

  • Coil Analyzers

    Sat40a II Series - Amperis sl

    The Coil Analyzer SAT40A II series is a powerful tool for testing circuit breakers where a substation battery is not available. It is unique device in the market due to its dual purpose: - It can be used as a stable power supply for coils and spring-charging motors (both DC and AC power supply voltage) during commissioning and maintenance testing. - It is powerful analysis tool for assessing conditions of circuit breaker auxiliary circuit and coils. The Coil Analyzer SAT40A II series has separate DC and AC coil outputs for power supply of opening and closing coils. The output voltage is selectable in the ranges from 10 V to 300 V DC or from 10 V to 250 V AC. The Coils outputs can withstand up to 15 A current. The DC and AC motor outputs can generate from 10 V to 300 V DC and 250 V AC voltage. The motor outputs can withstand starting (inrush) currents up to 40 A. These outputs can also be used as continuous power supply outputs.

  • IO-Link

    Analog Devices Inc.

    The IO-Link® interface simplifies communication to smart sensors and actuators, combining signaling with power-over-cable technology. It has become one of the key devices as industrial automation systems are growing more interconnected and intelligent to accommodate demands for centralized control and optimized production. Analog Devices implements both device PHY and master PHY interfaces (COM1/COM2/COM3). Designing with harsh industrial environments in mind, the master 4-port IO-Link power and communications interface, as well as the IO-Link transceivers featuring Integrated Step-Down Regulators and LDO with ±60V cable interface protection provide the required ruggedness. Optimum EMC performance is achieved with adjustable current limit and slew rate transmitters. Automatic wake-up request (WURQ) generation and an output supply current boosting capability for device startup are also available. Additional components integrate a 300 mA step-down (buck) regulator and a 150 mA LDO to supply all the power required for internal electronics in an connected sensor or actuator.

  • LED Driver Aging Rack

    LEDRACK-100W192P - Lisun Electronics Inc.

    • Application range: LED driver and multi channel driver power aging. It has equipped with computer operation and monitor system. The working condition can be set by the computer, and the computer will record real time data to do statistical analysis. • The parameters of load can be set freely on the software, to monitor the real time voltage, current, and power etc • Load mode: CC, CV, CR, CP, and LED • Aging Control System includes: ON/OFF control signal output; Signal of relay switch control; K type thermocouple temperature acquisition • The channels are parallel connected under arbitrary load mode, which can allow product power expansion • The LED Driver Aging rack will design according to customer’s LED driver power and aging quantity per time • Automatic current switching function (optional) • AC power meter to measure modules, and test power input characteristics (optional) • Temperature monitoring function at product zone (optional) • PWM dimming and two sets of logic control signal function (optional)

  • Voltmeter According to DIN EN 61010-1 (VDE 0411-1)

    PeakTech Prüf- und Messtechnik GmbH

    An innovative graphic multimeter with a 50,000-digit color TFT display for precise measurements with a high DC basic accuracy of 0.05%. The internal data logger enables the recording of measured values, which can be recorded over a period of several hours and the transfer to a Windows PC at a later time is ensured. Internally stored measured value recordings can also be accessed and graphically displayed on the multimeter itself or on the PC. Via Bluetooth, the measured values ​​can also be displayed live via app for Android and iOS devices, recorded in a table and e.g. send by email for further processing. This multimeter has a variety of measurement functions for direct and alternating voltage measurements (incl.ACV + DCV), direct and alternating current measurements, resistance, capacitance, frequency or temperature, whereby alternating voltage and alternating current are recorded as True RMS values. Due to the extensive measurement functions and the intuitive operation, this device is ideally suited for every electronics engineer, technician and engineer who attach great importance to a precise, indestructible and technically powerful multimeter.

  • DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER

    TURNS-LCRTZ - Vasavi Electronics

    Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the voltage across one turn and the coil. You will be able to get the polarity or winding indication with respect to the one turn reference.Accuracy : + 0.2% + 0.5T for high and medium permeability cores at suitable test frequency. Internal Diameter must be able to pass a wire as thin as 0.2 mm. External Diameter as high as 200 mm.Test Frequency Selectable in Step : 50 Hz, 100 Hz , 500 Hz, 1 KHz, 5 KHz, 10 KHz. Test Voltage adjustable : 100mV to 1V in steps of 50mV.

  • LED Power Driver ATS

    8491 - Chroma ATE Inc.

    1. DC Electronic Load : Chroma 6310A/6330A Series2. Transducer Unit/Module*1 : Chroma A849101/A849102, A849103, A8491043. Time/Noise Analyzer : Chroma 80611 & 80611N card4. Sytem Controller*2 : Industrial PC5. DC Source: Chroma 62000P Series6. Digital Power Meter : Chroma 66200 Series7. OVP/Short Circuit Tester : Chroma 806128. ON/OFF Controller : Chroma 80613*1 : A849101 transfers UUT output signal to voltage signal, and measure by 84911 LED power driver measurement card (200kHz). The optional 80611N Noise card is required for 20MHz ripplecurrent measurement.*2 : The controller includes both 84911 LED Power Driver measurement card and 84903 control card.- 84911: Measure rms current, dimming current/frequency/duty, timing, power & ripple current (200kHz)- 84903 : Provide BL control signal(DC level, PWM, SM bus), and enable ON/OFF signal.C Source : Chroma 6500/61500/61600 Series

  • Cost-Effective ATE System

    PRO RACK ATE - Qmax Test Technologies Pvt. Ltd.

    Pro-Rack is a cost effective ATE System, which comes with Modular Structure provision option to improvise and enhance much instrumentation based on the user’s requirements. Basically it is designed to cater to the needs of PCB test and repair depots, keeping in mind the changing PCB technology and the challenges in testing them off-line. It can provide complete PCB test and diagnostic functions for any kind of PCB including the latest very high density complex PCBs with high pin count PQFP, FPGA VLSI chips. AC /DC parametric tests enables testing of the DC parametric of device pins on the edge connector for input bias current, Fan out capacity ,Tri-state leakage currents, AC parametric measurements such as Input / Output Propagation delay Rise time / Fall time to further enhance fault coverage. Pro-Rack is designed with VPC Mass Interconnect adapter with 16 bit fixture ID interface to the UUT through simple clips and probes or through card edge or through a bed of nail test fixture.

Get Help