Showing results: 961 - 975 of 5324 items found.
-
LXinstruments GmbH
Leakage current and discharge current depend on the insulation of the device. The measurement simulates various fault situations that could occur during operation. The test determines whether the measured current is within the permissible limits and poses no danger to the user in case of a fault.
-
Weshine Electric Manufacturing Co., Ltd
Transformer K Factor, Power factors(PF)and displacement factors, Short-term voltage flicker, .Three phase unbalance (Current and Voltage), Waveform real-time display(4 channels voltage /4 channels current) True RMS values of voltages and currents
-
3921 CL -
Standard Electric Works Co., Ltd
● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication.
-
-
Carl E. Holmes Company
High voltage SCR controlled power supplies require the following:Output voltage is high. Output current is generally Low.Voltmeter and ammeter display the output voltage and current under load.Potentiometers are used to adjust output voltage and limit output current from minimum to maximum.
-
LAB SMP -
ET System Electronic GmbH
*Easiest operation via the front panel*Indication via graphic display*Constant current, voltage, resistance, power operation and simulation of PV characteristics*Creation of any voltage and current curves via memory card or digital interface (sequential control)*Voltage and current rise time (U and I slope) adjustable*Umax and Imax can be set by the user in order to limit the output voltage or current
-
72-8695A -
Tenma
*Bench top general DC power supply for laboratory use*Series or parallel operation*Master-slave tracking, constant voltage, constant current function*Auto switching between voltage and current operation*Synchronized 6 digits voltage and current display*Low noise*Current limitation*Mode selector switchNatural ventilation for cooling*12-month limited warranty *view Terms & Conditions for details
-
62075H-30N -
Chroma Systems Solutions, Inc.
Chroma’s new 62075H-30N ultra-high stability DC power supply offers many unique advantages for magnet power supply systems in synchrotron applications. These advantages include an excellent current stability of 1.25mA/0.5 hour and 2.5mA/8 hour, extremely low current ripple of 2.5mA, current reproducible within 10mA, precision setting and readback of output current via 20 bit DAC/24 bit ADC.
-
GF1061 -
Beijing GFUVE Electronics Co.,Ltd.
Test-901 current inject set adopts the ARM chip control output process and high capacity toroidal transformer, it can display the primary/secondary current.
-
EE-120A-3 + EE-500V-3 -
EMSYST Ltd
The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. The generated values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
4314 KV -
Valhalla Scientific Inc.
Model 4314 KV is a 4-wire ohmmeter designed to use low test currents for its measurement. Additional circuitry proprietary to Valhalla Scientific is used to ensure that test current levels do not exceed the specified “fail-safe current” even in a worst-case component failure situation.
-
MOTOMEA
Full load performance from stall up to no-load, without coupling to external load, including: torque, speed, current, auxiliary current, main current, voltage, capacitor voltage,input power, output power, power factor, motor efficiency,direction of rotation.
-
DER EE Electrical Instrument
A clamp meter is convenient for measuring instruments that allows the measurement of current simply by clamping a wire while being energized without cutting a circuit. In cases of measurement by a multitester and digital multimeter, the circuit must be cut to measure current. In contrast, with a clamp meter, current can be measured simply by clamping a live wire over its sheath. In addition to its simple operation, it allows safe measurement of a higher current.
-
Ajinkya Electronic Systems
Besides from physical parameters; application also demands logging of voltages and currents. The IM2000 series Voltage Logger / Current Logger / Power Logger offered by us can accept DC shunt inputs, signals from convertors 4-20mA range or CT current inputs for higher AC currents or AC signals from PT. These can calculate values from the recorded channels to generate additional channel values.
-
Precision Analog Systems Co.
Precision Analog Systems signal conditioning output amplifiers can increase the voltage output drive to +/- 200 Volts at 12 mAmps. Our high current amplifier cards provide 24 Volt output signals with 500 mAmps of output current. PAS offers boards that provide various combinations of output voltage and output current drive capability. Please see below for our current product list.