Showing results: 1336 - 1350 of 5316 items found.
-
Schwarzbeck Mess Elektronik
Helmholtz-Coils are especially designed to generate precisely defined magnetic fields from DC to the upper end of the audio frequency range and beyond. The generated fields are in a strongly linear relation to the coil current. The field- strength can be calculated exactly by analytical (or numerical) methods, based on the coils' geometry, the number of turns and the coil current.
-
410001 -
Sper Scientific
The small bodies and jaws fit perfectly in your hand and into tight places. Meter controls are positioned so that current measurements can be done with one hand. A large backlit display is easy to see, and the handy display hold function keeps measurements fixed on the display. Measures starting current for motors, lighting, etc.
-
410002 -
Sper Scientific
The small bodies and jaws fit perfectly in your hand and into tight places. Meter controls are positioned so that current measurements can be done with one hand. A large backlit display is easy to see, and the handy display hold function keeps measurements fixed on the display. Measures starting current for motors, lighting, etc.
-
Entes Elektronik
ENTES Harmonic Filter Reactors are used in serial connection with capacitor banks in power factor correction units. By using these types of detuned reactors it is possible to increase the capacitor impedance against harmonic currents and to keep the resonance frequency under the frequencies in which main harmonic currents occur by shifting the resonance frequency.
-
Schwarzbeck Mess Elektronik
Helmholtz-Coils are especially designed to generate precisely defined magnetic fields from DC to the upper end of the audio frequency range and beyond. The generated fields are in a strongly linear relation to the coil current. The field- strength can be calculated exactly by analytical (or numerical) methods, based on the coils' geometry, the number of turns and the coil current.
-
40-555A-011 -
Pickering Interfaces Ltd.
The 40-555A-011 is a high current 8x2 matrix occupying two slots of PXI chassis. Each matrix crosspoint uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation.
-
M-270 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Wide current measurements with tear drop type 55mmφCT up to 2000A.*True rms reading for ACA and ACV.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Auto zero adjustment for DC current offset.*Conform to IEC safety requirements.
-
40-555B-011 -
Pickering Interfaces Ltd.
The 40-555B-011 is a high current 8x2 matrix occupying two slots of PXI chassis. Each matrix crosspoint uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation.
-
8100 C -
Kusam Electrical Industries Limited
INPUT :• Input Voltage Range :Voltage: 55 ~ 300V AC, or 300 ~ 600V AC, 45 ~ 65Hz.P.T. Ratio Programmable upto 9999 / KV.• Input Voltage Over Range :Voltage : 200 % Continuous, 300 % of rating for 10 sec.• Input Current Range :Current : 110 % of rating. 0-1A or 0 - 5AC.T. Ratio programmable upto 9999 / 5A.Input Current Over Range:Current : 400 % Continuous, 2000 % of rating for 10 Sec.• Input Frequency : 45 Hz ~ 70 Hz.• Input Burden :Voltage 0.25 VA / Unit, Current 0.25VA / Unit, at 50 / 60HzOUTPUTDC Current: 0 20 m A DCLoad resistance drive: output drive 10 V DC maximum.DC Voltage: 0 -10 V DCLoad resistance drive: output drive 5mA maximumOutput Protection: No damage even if output is Open or Short Circuit.Output Response Time : £ 1 Sec.Digital Output : RS485 Output, Isolate Type with MODBUS RTU mode., 4800, 9600,19200Baud Rate, User Selectable.
-
61600 Series -
Chroma ATE Inc.
Built-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable voltage,current limitComprehensive measurement capability,V, Hz, Irms, Ipk, Iinrush, P, VAR, VA, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlOne-key recall for 9 different voltage and frequencyProgrammable slew rate setting for changing voltage and frequencyAnalog input for power amplifierOptional Analog programming interfaceOptional GPIB and RS-232 interface(Model 61601~61605)Full protection: OP,OC,OV and OT protectionEasy use graphic user interface: softpanel (option)Capable of delivering power output up tp 90KVA by implementing Master-Slave operation
-
DCS Series -
AMETEK Programmable Power, Inc.
The DCS Series of 1 kW, 1.2 kW and 3 kW programmable power supplies provides a highly reliable power platform. It utilizes unique packaging techniques to achieve continuous full output power (1 kW, 1.2 kW or 3 kW) in any volt/amp combination within the rated output voltage and current limits in a low profile chassis. This DCS power supply family has an easy-to-use front panel with 10-turn potentiometers to adjust voltage and current settings that are displayed simultaneously. LEDs indicate overtemperature, remote programming, shutdown and over voltage protection, status and constant-voltage/current mode operation. The DCS 3 kW Models have push button control of the output standby mode, OVP reset, remote/local programming and preview status of voltage, current and OVP setpoints.
-
CAEN S.p.A.
- From 12 to 24 independently controllable High Voltage channels- 8 kV maximum output voltage- Maximum Current 1 mA- Either Radiall Multipin or SHV connectors- Available with either positive or negative polarity- Up to 500 pA/50 pA current set / monitor resolution- Up to 100 mV/10 mV voltage set / monitor resolution- Very Low ripple, down to < 5 mV- 3 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx) - Individual Floating (A1534 only)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down (1 ÷ 500 V/sec) - TRIP parameter- Current generator operation in overcurrent condition- Specific design for Germanium detectors (A15x0H only)
-
ALS Co., Ltd
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
E3649A -
Keysight Technologies
Output ratings (@ 0C to 40C) 2 outputs Range 1: 0 to 35 V / 1.4 ARange 2: 60 V / 0.8 A Programming accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 10 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.2% + 10 mARipple & noise 20 Hz to 20 MHz Normal Mode Voltage: <8 mVpp / 1 mVrms Normal Mode Current: <4 mArms Common Mode Current: <1.5 uArms Readback accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 5 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.15% + 5 mA (<0.15% + 10 mA for output 2 of E3646/47/48/49A)
-
FuG Elektronik GmbH
Autoranging power supplies are power supplies with stepless range adjustment . Within a fixed power limit - up to max. 9,000W - the full output power is delivered over a wide voltage and current range. The working range is not only extended by higher voltage, but also by higher current. The output voltage is between 150V and 3000V.