Showing results: 1351 - 1365 of 5323 items found.
-
Laurel Electronics, Inc
The Laureate? True RMS meter offers a high accuracy 4 1/2 digit display for five voltage ranges and four current ranges. It is suited for AC applications where there is considerable distortion of current waveforms from nonlinear loading. The input is AC coupled to read only the AC component, such as ripple on a power supply.
-
MPS-H-1 Series -
Matrix Technology Inc.
MPS-H-1 series DC power supply is a new generation of high-quality linear DC power supply, with remote voltage compensation function, automatic conversion of voltage stabilization and current, high stability, high reliability, high precision, and display output voltage and current at the same time. Very high cost-effective advantage.
-
The Swain Meter Company
The Swain Meter™ Company manufactures portable clamp on DC ammeters that precisely measure the magnitude and direction of DC current flow on any conductor. Used both onshore and offshore, Swain DC clamp on amp meters accurately read current from 5mA to 200 Amps with a resolution of 1mA in the 0-2Amp range.
-
MCL-800D+ -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・80mm x 74mm CT window and wide current measurements from 0.01mA to 1000A.・With filtering switch (which cuts currents above 150Hz)・Maximum value hold / Data hold function available・Auto range switch that selects the optimum range according to the measured value・Easy to read large display
-
Elmeasure India Pvt. Ltd
Multiple channels can be measured by a single meter, EN2450N & EN2450DDifferential current input for all the current channelsProgrammable shunt secondary 50mV to 100mVProgrammable CT Primary for all channels up to 200A - for Hall Effect CTData logging for parameters such as Energy, Load hours and Ampere hoursEasy installation,Compact size, weight and simple wiring
-
ITC55100C -
Integrated Technology Corp.
The system has been designed around a very powerful micro-controller that gives it a timing resolution of 40ns, twenty times faster than the previous model. Its response time to the peak and zero current is improved ten times. Combined this gives greater accuracy for the charging and avalanche times and for the reported peak drain current.
-
B2912B -
Keysight Technologies
The Keysight B2912B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
B2902B -
Keysight Technologies
The Keysight B2902B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
B2901B -
Keysight Technologies
The Keysight B2901B precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
1394A -
Ballentine Laboratories, Inc.
Nominal Heater Current: 5 mA rms,Max. Heater Current: 7.5 mA rmsCouple Output: 7 mV ± 12% at nominal heater current.Couple Resistance: 8 W ± 20%.Maximum DC Reversal Error: ± 0.04%Couple Output Voltage to Heater (ground): ± 50 V (dc + acpk-pk) max.
-
Schwarzbeck Mess Elektronik
The magnetic, handheld coil was designed to generate defined magnetic field strength in the audio frequency range up to 3 MHz. The main application is immunity testing against magnetic fields according to VG 95377 Part 13 and many others. Depending on the current source characteristics magnetic fields up to 400 A/m can be generated for a short time.There are further rings available on request in order to provide a certain scaling between coil current and magnetic field strength (e.g. 1 Amp coil current = 10 A/m field strength).
-
Chroma 16502 -
Chroma Systems Solutions, Inc.
With a basic accuracy of 0.05%, Chroma 16502 offers a 0.001mΩ ~1.9999MΩ wide measurement range. It provides measurement range with 4 1/2 digits resolution. The fast measurement time is 65 ms. It suits component evaluation on production line. Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurement. DC test current output mode is used to fasten measurement speed for inductive DUT. Dry-circuit test current output mode is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 20mV.
-
SKS-0510I -
Shanghai Sanki Electronic Industries Co., Ltd.
The lightning surge generator SKS-0510I fully complies with the new standards of IEC61000-4-5, EN61000-4-5 and GB/T17626.5; it provides pulse test voltages up to 10kV, which can meet the severity levels of various product standards; Covers the two surge waveforms specified in the standard 1.2/50ms (short-circuit current is 8/20μs) and 10/700ms (short-circuit current is 5/320μs), and a variety of internal resistances are built-in for customer use; Two kinds of surge waveforms, and built-in a variety of internal resistances for customers to use; AC and DC samples can be tested, the rated current can reach 32A.
-
-