Showing results: 31 - 45 of 47 items found.
-
785034-01 -
NI
PXIe, Rubidium PXI Synchronization Module - The PXIe-3352 generates high-stability clock signals for PXI or third-party instrumentation. It provides a high-accuracy sine wave, square wave, or 1 pps output, and it includes a built-in GPS receiver (external antenna required) to discipline the rubidium oscillator for long-term stability. The front panel DC power input maintains power to the rubidium oscillator if the PXI chassis is powered off, keeping the rubidium oscillator stable over time and eliminating the effects of retrace. The GPS receiver also maintains its location information during power off for fast system bring up.
-
EL Series -
Manatronics Pty Ltd
*12kW, 15kW and 18kW DC Electronic Load*All of our Load Banks are continuously rated for Power and Current.
-
BD Series -
Manatronics Pty Ltd
*12 kW, 15kW and 18kW Battery Discharge Load DC*All of our Load Banks are continuously rated for Power and Current.
-
XLHV Medium Voltage Series -
Mosebach Manufacturing Company
The XLHV range offers you a continuous load at higher voltages in an outdoor rated enclosure. These can be for AC or DC load banks up to 15kV.
-
Ohm Loads Powertek Inc.
Our STANDARD AC AND DC LOAD BANKS are easily configured for other voltage, current and power ratings. These MODIFIED STANDARD LOADS are built to the customer’s exact design specifications at Standard Load Bank pricing and shipping schedules. Our goal is to supply a product with input from the end-user.
-
Junxy Energy
AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
-
Simplex Inc
The Simplex Watt-Muncher is a small DC rated load bank used to test battery systems, AC to DC rectifiers and power supplies, battery chargers, UPS systems and DC generators. The Watt-Muncher provides a variable test load used to measure charge and discharge rates, response, stability and endurance. Corresponding calibrations and adjustments can be made while maintaining a constant, precise, resistive load on the power source.
-
902804 -
Miller Electric Mfg Co.
The welding power load bank is designed to load test the output of transformer-type, engine- or motor-driven generator welding power sources. This unit can be used to test AC or DC welder outputs, and to demonstrate welding equipment to customers.
-
K-3980 -
Kongter Test & Measurement Co., Limited
Kongter offers a series of customized DC load banks with many different models for constant current battery discharge test and battery capacity test. They cover a wide voltage range from 12V to 480V nominal voltages with current up to 600A. They are widely applied in various industries. With its optional battery Data Acquisition Case (DAC), discharge values of EACH cell could be monitored in battery load bank and PC software simultaneously by using Kongter’s data view software.
-
Swift -
Simplex Inc
Quick and easy testing of small generators is possible with the Simplex Swift-e Portable Load Bank. Fully self-contained, lightweight and hand transportable, the Swift-e can be used to test and maintain engine generators, inverters, batteries, battery chargers, rectifiers and small UPS systems. Swift-e's are available as AC or DC units with capacities up to 15,000 watts of load switchable in 250W increments.
-
DC7000 -
Cressall Resistors Ltd
A purpose-built load bank for the performance testing of engines and generators of all types of diesel electric locomotive up to 4000hp rating, with easy-to-use resistance adjustments allowing tests to be carried out over the whole power envelope. Capacity 0 7000A continuously at up to 2000V DC
-
BDL-3926C -
Kongter Test & Measurement Co., Limited
BDL-3926C Battery Data Logger is wireless monitoring device for string voltage, cell voltage, current and temperature. It works individually to reflect battery status or co-works with Kongter’s other battery test equipments like battery charger and K-3980 DC load bank. For different battery systems, it has customized configuration from 12V to 480V or upper. And it has easy expansion for all battery systems.
-
40-659-102 -
Pickering Interfaces Ltd.
Model 40-659 is an 8 Bank 8 Channel Multiplexer module with 2-pole switching, It uses high quality electromechanical relays and is suitable for switching signals up to 2Amp, 300VDC/250VAC.The 40-659 module is suitable for multiplexer applications where two signals are required to be switched simultaneously, for example send and return signals in a telecoms system. It is also suitable for applications where reed relay based multiplexers do not have sufficient power handling capability such as switching medium power AC or DC loads or for slaving external relays, contactors and solenoids.
-
40-659A-102 -
Pickering Interfaces Ltd.
Model 40-659A is an 8 Bank 8 Channel Multiplexer module with 2-pole switching, It uses high quality electromechanical relays and is suitable for switching signals up to 2Amp, 300VDC/250VAC. The 40-659 module is suitable for multiplexer applications where two signals are required to be switched simultaneously, for example send and return signals in a telecoms system. It is also suitable for applications where reed relay based multiplexers do not have sufficient power handling capability such as switching medium power AC or DC loads or for slaving external relays, contactors and solenoids.
-
Bloomy Controls, Inc.
The Energy Storage System (ESS) Performance Test System is used to evaluate, test, and certify the performance of energy storage systems up to 2MW. The system is a configurable platform with over 200 channels of simultaneously measured AC and DC voltages and currents, environmental temperatures, airflow, and communications. Intuitive software provides real-time monitoring and analysis of power, energy and efficiency to adhere with industry standards. The test system interfaces hardware such as load banks, and controls the ESS to simulate utility applications such as peak shaving and frequency regulation.