Showing results: 2566 - 2580 of 3724 items found.
-
RP7972A -
Keysight Technologies
The RP7972A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.
-
RP7983A -
Keysight Technologies
The RP7983A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.
-
RP7984A -
Keysight Technologies
The RP7984A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.
-
RP7973A -
Keysight Technologies
The RP7973A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.
-
SM-4060MHz -
MCH Instruments Co.,Ltd.
Waveforms*Main Waveforms: sine, square(only sine is available above 20MHz)*Waveform length: 8~16000point*Amplitude resolution: 12bit*sampling rate: 200MSa/S(≤80MHz) 300MSa/S(120MHz)*Built-in Arbitary: Triangle,±Ramp, ±pulse,rise/fall exponential,rise/fall logarithm,gause noise,cardiac,SIN(X)/X,DC*Waveform length: 8~160000point*Amplitude resolution: 10bit*sampling rate: 10MSa/S(≤80MHz) 20MSa/S(120MHz)
-
Elcontrol Energy Net S.r.l.
NanoVIP® ONE™ is a modern power quality analyzer equipped with all the functions necessary for measuring and monitoring both electricity consumption and the main power quality parameters.It can be used on single-phase and three-phase balanced networks in low and medium voltage as well as on DC systems.Particularly compact in size, it uses commercial AA batteries (rechargeable or not), has a considerable internal storage capacity (4Gb) and a graphic display.An affordable analyzer but suitable for professional use.
-
W-IE-NE-R, Plein & Baus GmbH
NIM and CAMAC crates require very clean and stable DC supplies with the standard voltages +24V / -24V, +12V / -12V and +6V / -6V. Consequently CERN defined compatible power supplies for both standards within their NIM and CAMAC specs., i.e. CERN spec. power supplies can be used on both types of crates. All "CE" version power supplies are outfitted wth separate AC wiring to comply with CE/UL safety standards.
-
AD14-500x4-8GB-K7US -
Ultraview Corporation
The AD14-500x4-8GB-K7US is a high performance wideband 4-channel 14-bit data single PCIe Gen3 board, that can continuously digitize four wideband signals, with four high linearity A/Ds.Designed for demanding military, medical, scientific, industrial, communications, safety and electrical power utility applications, these boards have a wideband noise figure of 10dB and 1 dB peak-to-peak ripple over the DC to 250MHz frequency spectrum (2dB p-p over DC-500MHz).
-
MC141 -
Powertek LLC
Voltage range from 0 to 750 V DC/AC with uncertainty 0.01% Current range from 0 to 2 A DC/AC with uncertainty 0.02 % Calibrated sinusoidal output signal DC - 1kHz. Set standard resistors from 10 Ohm to 100 MOhm in decade values with uncertainty 0.02 %. TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250 oC to 1850 oC
-
I-prober 520 -
Aim-TTi
Current measurement from insulated probing of conductorSuitable for observation and measurement of current in PCB tracks, component leads and ground planesWide dynamic range of 10mA to 20A peak to peakWide bandwidth of DC to 5MHzLow noise figure equivalent to <6mA rms at full B/WSafety rated to 300V Cat II (600V Cat 1)Suitable for connection to any oscilloscopeHigh accuracy general purpose H-field probeConverts to 'closed magnetic circuit' current probe
-
Arrow Tech
Probe has a mica window that has a thickness of 1.8 to 2.0 mg/cm2. This allows detection of alpha radiation as low as 3.0 MeV when in close proximity to the window. Beta radiation in excess of 35 keV and X-ray or gamma radiation greater than 6 keV can also be deteched. The detector is provided with a BNC connector. It can be used with most count rate and survey meters which accept Geiger Mueller (GM) detectors operating at 900V DC.
-
ET Power Systems Ltd.
The rectifier families are housed in either 19" racks or provided as compact modules. The rack mounting rectifiers are aimed at telecoms applications. This range of robust rectifiers start at 250W and have a life time of more than 8 years and an MTBF of over 50 years. For even greater security these hot swap modules can be configured to provide a redundant DC output. Up to 2 additional AC inputs with automatic switchover are provided on a number of these telecoms rectifiers.
-
Insulation Tester -
MEET International Ltd.
*Tests insulation upto 4Gohm with 4 different voltage range : 125V ; 250V ; 500V ; 1000V ( > 1mA )*Pre-set timer settable*Good / NG comparison*Auto high voltage detection*AC voltage test upto 1000V*DC voltage test upto 750V*Resistance test*Continuity check ( > 200 mA )*NCD’ Non-Contact AC Voltage Detection with patented numerical display AC signal strength ( > 50V AC )
-
Metrix
Seismic signal conditioners are designed to accept an input from (and provide power to) a seismic sensor. They convert the signal to a proportional 4-20mA DC signal that can be used as an input to process control instrumentation such as a PLC or DCS. They provide additional convenience features such as optional displays, BNC connectors for access to the dynamic sensor signal, and bandpass filtering. Metrix offers seismic signal conditioners that can accept either acceleration or velocity sensors, and are available with or without an integral display.
-
F9 Systems, Inc.
This ATCA compatible test card offers the flexibility to verify the performance of Advanced TCA fabric and base channels. The set of four Transmit pairs and four Receive pairs allows access to a full channel's eight pairs for backplane path characterization. The card includes a HM-ZD connector segment for access to the backplane and edge-launch SMA connectors for ease of test cable attachment. DC blocking capacitors are included on the receive pairs as required by Advanced TCA.