Filter Results By:

Products

Applications

Manufacturers

Detectors

register the presence of a stimuli.

See Also: Metal Detectors, Particle Detectors, Sensors, Charge Sensitive Preamplifiers


Showing recent results 466 - 480 of 548 products found.

  • Standard Lifetime Measurement System

    Filter-Based Systems - Becker & Hickl GmbH

    *Excitation by bh ps Diode Lasers (BDS-SM or BDL-SMN Series)*Optional: fs Fiber Laser*Wavelength Selection by Filters*Detection by bh HPM-100 Hybrid Detectors*Excellent Dynamic Range*Ultra-High Time Resolution*IRF Width Down to 40 ps FWHM with HPM-100-06/07*Low Cost Detector Option: PMC-150 PMT Modules

  • Neutron Detection Solutions

    Saint-Gobain Crystals

    NeuPortTM and NeuTruckTM solutions provide a cost effective plug-and-play replacement to He-3 for portal and vehicle mounted monitors. These are 6LiF/ZnS(Ag) based flat packaged neutron sensitive detectors contained in high density polyethylene moderator enclosure. Neutrons are captured by the 6Li and the reaction products excite emission from the ZnS(Ag) scintillator which in turn is absorbed in an adjacent ribbon of wavelength shifting fiber.

  • Ultrafast Joulemeter

    Gentec Electro Optics, Inc.

    Measure every pulse at up to 200 kHz with MACH 6. Measure with 12-bit digital accuracy and capture up to 4 million pulses in real time. Our MACH 6 Joulemeter is the only instrument in the world that performs at this speed, and with this precision. It is designed to support our full complement of fast energy probes that include Silicon, InGaAs and Pyroelectric Detectors. Measure from pJ to mJ and from 0.35 to 2.5 m. Using the M6-Si detector and the M5-UC-QED accessory, you can make relative measurements at 266 nm.

  • Meter Active Peak Reading Wattmeter

    HF/6 - Dishtronix Inc.

    Active peak reading wattmeter with simultaneously variable hold time on both the forward and reflected meter movements. This variable delay can be adjusted for quick action for high speed CW, or for longer periods more appropriate for the display of SSB and AM voice peaks. The peak detectors sport a new fast attack design capable of capturing quick pulses such as a single dit. Beautiful industrial design with tri color meter scale and brilliant LED illumination make the DWM series wattmeter a beautiful addition to any station.

  • Radiometry System

    LIDA-SRS-KIT - Newport Corporation

    The LIDA-SRS-KIT Lock-In Digital Amplifier system provides an effective and user-friendly method for measuring optical signals. The system includes Oriel’s TracQ™ Basic software that acquires spectroscopic measurement data quickly and easily, without requiring any programming knowledge. The chopper included with the system is used to modulate a continuous wave source for detectors – a requirement when using a lock-in digital amplifier.

  • Hand-Held Metal Detector

    NF-511 - Shenzhen Noyafa Electronic CO.,LTD

    The metal detector is a portable electronic instrument which detects the presence of metal nearby. Metal detectors are useful for finding metal inclusions hidden within objects, or metal objects buried underground. They often consist of a hand-held unit with a sensor probe which can be swept over the ground or other objects. If the sensor comes near a piece of metal this is indicated by a changing tone in earphones, or a needle moving on an indicator. Usually the device gives some indication of distance; the closer the metal is, the higher the tone in the earphone or the higher the needle goes.

  • Radon Professional Monitoring

    Bertin Instruments

    Our dedicated range of products and accessories has been especially designed to fit these needs and to provide accuracy in the following application fields: Short and long-term monitoring of radon concentration indoor and outdoor, water and soil gas analysis Radon surveillance and mitigation at workplaces (according to valid radiation protection regulations) Geological survey, e.g. vulcano watching, earthquake surveillanceAlphaGUARD products reputation is worldwide recognized, as a reference device for calibration for active and passive radon detectors.

  • Fluorometers

    QuantaMaster™ 8000 Series - HORIBA, Ltd.

    Highest guaranteed sensitivity specification at 30,000:1 Water Raman RMS. World class software for all steady state and lifetimes needs. Extended wavelength range with triple grating monochromators. Ultimate flexibility with up to four light sources and six detectors that can be selected. Fully automated system. Best in class stray light rejection with large single or double additive, coma corrected, monochromators.

  • Earth Magnetometer

    EM2 - Alpha Lab, Inc.

    The Earth Magnetometer Model EM2 measures small variations from location to location in the Earth magnetic field associated with buried magnetic masses. Unlike metal detectors, a magnetometer signal is not attenuated by rock, dirt, mud or water, so targets can be detected at great depth. (If D is the diameter of a mass of magnetizable material, the EM2 can detect it as deep as 40 times the diameter D, whether the mass is specifically magnetized or not.) It is the lightest weight and lowest cost magnetometer available which can reliably measure differences down to 1 nT from point to point.

  • Insertion Loss Testing

    OptoTest Corp.

    Measures insertion loss on simplex optical fiber cables by using continuous wave (CW) sources in conjunction with a high quality optical power meter. With a customizable selection of sources, fiber types, detectors, and front panel connectors, the OP815 is the ideal solution for measuring IL on any simplex cable.

  • Component Filter Test System

    Model 3150 - TSI Inc.

    The Component Filter Test System (CFTS Model 3150) from TSI, consists of software and a hardware module to provide an off the shelf solutions for all your custom filter testing needs. Pre-configured to work with TSI’s world class detectors and sizers the CFTS provides a platform for numerous filter test applications.

  • Powerful, Fully Integrated Workstation for Emission Microscopy

    PEM-1000 - Korima, Inc.

    The PEM-1000 emission microscope incorporates the latest technology in real time, high quantum efficiency, mega-pixel CCD detectors in a back-thinned cooled camera. A portable system, the PEM 1000 can interface with all analytical probe stations, ATE (automated test equipment) and bench top configurations for high speed functional testing.

  • Ground Fault Protection Monitors

    Accumetrics Associates, Inc.

    The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.

  • 3-AXIS DIGITAL AC GAUSSMETER: 1-200 kHz

    IDR-200 - Integrity Design and Reseach Corp.

    Typical Applications include checking the frequencies and magnetic fields (BW: 1 kHz -200 kHz) produced by equipments such as computer monitors, television sets, video display terminals, induction heaters, industrial, Radar, scientific/medical equipment, walk-through/hand-held detectors and ground wave energy network; etc. For more information about VLF magnetic fields and the VLF gaussmeter , see the paper titled "Very-low-frequency electromagnetic field detector with data acquisition," IEEE Trans. Instrum. Meas.,vol. 58, no. 1, pp. 129-140, Dec. 2008. by S. Hanna.

  • Antenna Analyzer

    AIM-4300 - Array Solutions

    It measures the complex impedance (magnitude and phase) at each frequency of interest in the range of 5 kHz to 300 MHz. A PC is used to calculate all RF parameters, including R +/-jX, Magnitude and Phase, SWR, Return Loss, TL loss, and more and plot the results in an easy to read graph and interactive Smith Chart.The test frequency is generated digitally and bandpass filters are used to reject stray signals (like broadcast stations) that are more than a few KHz from the operating frequency. A 12 bit analog to digital converter digitizes the raw data. This avoids non-linearities associated with diode detectors, and results in very good dynamic range and linearity for accurate magnitude and phase measurements.