Filter Results By:

Products

Applications

Manufacturers

Detectors

Register the presence of a stimuli.

See Also: Metal Detectors


Showing results 481 - 495 of 551 products found.

  • Charge Sensitive Preamplifier-Discriminator

    A111 - Amptek Inc.

    Model A111 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing microchannel plates (MCP), channel electron multipliers (CEM), photomultipliers, proportional counters and other low capacitance charge producing detectors in the pulse counting mode. Laboratory and commercial applications include aerospace and portable instrumentation, mass spectrometers, particle detection, imaging, laboratory and research experiments, medical electronics and electro-optical systems.

  • Hydrogen Leak Detector

    HY-ALERTA - H2scan Corp.

    H2scan’s HY-ALERTA™ product line includes a range of state-of-the-art, portable hydrogen leak detectors and fixed area hydrogen monitors designed to ensure safety within an enclosed or open area where there is the potential for a hydrogen leak. These products ensure around-the-clock safety by preventing explosions and provide unmatched performance within many industries such as: fuel cells, nuclear, coal, gas, and where hydrogen generators, battery rooms and hydrogen electrolyzers are used.

  • Electron Multipliers

    Hamamatsu Photonics K.K.

    Electron multipliers are mainly used as positive/negative ion detectors. They are also useful for detecting and measuring vacuum UV rays and soft X-rays. Hamamatsu electron multipliers have a high gain (multiplication factor) yet low dark current, allowingoperation in photon counting mode to detect and measure extremely small incoming particles and their energy. This means our Hamamatsu electron multipliers are ideal for electron spectroscopy and vacuum UV spectroscopy such as ESCA (electron spectroscopy for chemical analysis) and Auger electron spectroscopy as well as mass spectroscopy and field-ion microscopy.

  • Attenuators

    Shenzhen Tojoin Communication Technology Co., Ltd.

    Attenuators are used in a wide variety of applications and can satisfy almost any requirement where a reduction in power is needed. Attenuators are used to extend the dynamic range of devices such as power meters and amplifiers, reduce signal levels to detectors, match circuits and are used daily in lab applications to aid in product design. Attenuators are also used to balance out transmission lines that otherwise would have unequal signal levels.

  • X-RAY PHOTODIODES

    AMS Technologies AG

    The large active area high speed detectors can be fully depleted to achieve the lowest possible junction capacitance for fast response times. They may be operated at a higher reverse voltage, up to the maximum allowable value, for achieving even faster response times in nano seconds. The high reverse bias at this point, increases the effective electric field across the junction, hence increasing the charge collection time in the depleted region. Note that this is achieved without the sacrifice for the high responsivity as well as active area.

  • Data Reporting and Analysis Software

    TRACS - Loma Systems

    TRACS (Trending-Reporting-Analysis-Capture-Software) is a graphical reporting software tool, which runs over a network and captures data from connected machines for analysis and reporting from a remote computer. Developed in partnership with AutoCoding Systems, TRACS displays live and historical batch data for all production runs and is designed to work with LOMA’s Metal Detectors, Checkweighing, X-ray Inspection and Combination Systems.

  • OVERALL ACOUSTIC LEVEL METER (OVA)

    OROS sa

    With an OROS 3-Series you get a multi-channel analyzer, so, why not turn your unit into a true multi-channel sound level meter. The OVA plug-in extends the analyzer capabilities to a comprehensive acoustic measurement system. The OVA complies with the latest standards such as IEC 60-672. It runs 3 RMS and a peak detector on each input. The detectors feature time filtering and weighting.

  • Components

    Teledyne Microwave Solutions

    Microwave Solutions is a worldwide leader in the design, development, and manufacture of RF and microwave components. Our broad line of components operate in the 100 kHz to 26GHz range and include Attenuators, BAW Devices, Detectors, Isolators and Circulators, Linearizers, Mixers, and VCOs. For over 50 years our components have played key roles in sophisticated airborne and satellite communications equipment, navigation and guidance systems, radar and sonar equipment, telemetry electronics, surveillance, and reconnaissance systems, and high performance commercial test equipment.

  • Photodiodes

    Opto Diode

    Opto Diode manufactures high quality standard and custom photodiodes. Our wide range of standard device feature low dark current and low capacitance. The silicon detectors are ideal for general purpose applications, laser monitoring, position sensing, measuring photons, electrons, or X-rays, or for detecting sun and rain applications. The devices operate from the deep UV to the near-infrared wavelengths.

  • Neutron Detection Solutions

    Saint-Gobain Crystals

    NeuPortTM and NeuTruckTM solutions provide a cost effective plug-and-play replacement to He-3 for portal and vehicle mounted monitors. These are 6LiF/ZnS(Ag) based flat packaged neutron sensitive detectors contained in high density polyethylene moderator enclosure. Neutrons are captured by the 6Li and the reaction products excite emission from the ZnS(Ag) scintillator which in turn is absorbed in an adjacent ribbon of wavelength shifting fiber.

  • Extreme Environment

    Ruggedized - Saint-Gobain Crystals

    Our detectors, as integral components of gamma ray logging tools, provide superior performance and survivability under the most extreme environmental conditions. The newer generation of exploration and production logging tools place incredible performance demands on scintillation-based sub-assemblies.  Several patented features in Saint-Gobain crystal packages and our series of integrated detector designs provide gamma logging professionals significant advantages.

  • Portable Radiation Measurement

    Mirion Technologies

    Handheld radiation meters provide accurate radiation measurements across a wide variety of applications. From performing hand held gamma radiation surveys, to measuring alpha and beta, radiation detectors make it easy to perform the measurements critical to any radiation safety program. These radiation meters provide flexible options for most basic radiation detection scenarios.

  • StellarNet Spectrometer Models

    StellarNet Inc

    StellarNet miniature spectrometers are portable & compact fiber optic instruments for UV, VIS, and NIR measurements in the 190-2300nm range. The StellarNet series of miniature spectrometers is a step up in low cost instrument design, offering CCD 2048 & PDA 512/1024 detectors. The units are engineered to have no moving parts, no detector sockets, ruggedized aluminum enclosure, and an integrated A/D digitizer for unmatched durability and quality that out performs any instrument in its class. Numerous models offer standard or high resolution (HR) optics for selected spectral ranges.

  • Radiation Detection

    Fluke Biomedical

    Radiation detectors for safety quality assurance is top of mind for hospitals, nuclear power facilities, nuclear medicine laboratories, x-ray manufacturers, government agencies, state inspectors, emergency response and HAZMAT teams, and police and fire departments around the world. Fluke Biomedical offers a complete line of radiation detection, personal dosimeters, staff radiation dosimeter monitoring, and safety products and solutions that allow these professionals the versatility they need to get the job done and the quality they trust in a radiation-safety device.

  • Track and Hold Data

    Analog Devices Inc.

    Track and hold amplifiers are used to expand the bandwidth and/or high-frequency linearity of high-speed A/D conversion and signal acquisition systems. Track and Hold Amplifiers can be used in various applications including RF ATE Applications, Digital Sampling Oscilloscopes, RF Demodulation Systems, Digital Receiver Systems, High Speed Peak Detectors, Software Defined Radio, Radar, ECM & ELINT Systems and High Speed DAC De-Glitching.