  • sbRIO-9239, Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    780875-01 - NI

    Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the sbRIO‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range. Non-enclosed modules are designed for OEM applications.

  • PXI Multiplexer Switch Module

    NI

    PXI Multiplexer Switch Modules are ideal for high-channel-count applications that need to connect measurement or signal generation instruments to various test points on devices or units under test(DUTs or UUTs). PXI Multiplexer Switch Modules use a variety of relay types, including electromechanical armature relays, reed relays, field-effect transistor(FET) relays, and solid-state relays, each with their own benefits, allowing you to choose a multiplexer that fits your requirements. To program the switches, you can use the IVI-compliant NI-SWITCH driver software, complete with help documentation, example programs, and a soft front panel application for interactive control of switches. For intelligent management of complex switch systems, NISwitch Executive provides additional software tools to help you design, build, and deploy your switching system.

  • Patch Panel Automation Switch

    Echola Systems LLC

    Echola's Optical Patch Panel Automation switch allows test engineers/system developers to dynamically reconfigure testbed connections from remote. It reduces test configuration time as they don't need to make any physical fiber connections for each set of tests, so more testing can be performed with fewer resources. It provides all-optical connectivity with zero latency and can be used with any protocols and speed. Unlike O-E-O (optical to electrical to optical conversion) switches you don't need expensive transceivers for each port. The all-optical connectivity also allows systems under test to be tested without introducing another variable (ie, another conversion layer which could introduce significant latency). The patch panel automation switch allows users to configure, control and monitor the device from remote using any standard internet browser, a command line interface (CLI) via Telnet or SSH and SNMP v2c. The event notifications are supported through Syslog. It can be automated using TCL based scripts.

  • Digital Triple Output DC Power Supply - Adjustable to 30V/3A with fixed 5V and 12V outputs

    Extech 382213 - Extech Instruments Corporation

    Ideal for a wide range of applications including bench testing, field service, hobby and telecommunication equipment, the solid state, compact Extech 382213 digital DC power supply delivers clean, reliable power while protecting itself and any device under test (DUT) from damage. It offers three choices of power output: adjustable 0-30-Volt, 0-3-Amp, plus fixed 5- and 12-Volt. Featuring a digital LCD display, the 382213 also includes overload and short circuit protection, constant voltage/current, easy snap terminals for 5- and 12-Volt outputs, and a current-limited front panel LED indicator. Complete with power cord.

  • Chamber/Pyroelectric Task

    Radiant Technologies, Inc.

    Radiant's Chamber/Pyroelectric Task sets the sample to a series of temperatures by performingGPIB control of an external thermal device. At each temperature it captures the sample’s polarization response and/or small-signalcapacitance. These are combined to calculate the pyroelectric coef­ficient.  The Pyroelectric Task is to be used with a Radiant Test System and a Linkam Stage (-196C to 600C), Thermal Chambers, Hot Chucks, or a Furnace to automatically measure the Pulse Polarization response and Small Signal Capacitance of a Pyroelectric material that is being heated and/or cooled.  Radiant's Pyroelectric measurement Task can be added to Vision at additional cost.  This measurement suite fully characterizes the pyroelectric charge (polarization) response of the sample under test.  The Pyroelectric Task suite controls various thermal controllers such as Quantum Design, Lake Shore, Delta Design, and many others. Detailed Listing of Thermal Controllers Registered in Vision.   The Chamber/Pyroelectric Task is quoted upon request.

  • High Flexibility VNA Cables

    Fairview Microwave Inc.

    Our lines of high frequency VNA test cables display excellent electrical properties such as wonderful phase stability of +/- 6° at 50 GHz and +/- 8° at 67 GHz as well as VSWR of 1.3:1 at 50 GHz and 1.4:1 at 67 GHz. The 50 GHz assemblies are terminated with 2.4mm connectors while the 67 GHz versions utilize 1.85mm connectors. The braided stainless steel armoring surrounding the coax provides a rugged, but flexible cable with a flex life exceeding 100,000 cycles, making these test cables ideal for use in semiconductor probe testing, precise bench top testing as well as lab/production testing where the need for a highly flexible, yet durable cable solution is required. The VNA test cables are also equipped with rugged stainless steel connectors that provide up to 5,000 mating cycles when attached with proper care. Additionally, the flexibility of these cables makes it easier and safer to test a Device Under Test (DUT). A swept right angle 2.4mm and 1.855mm connector option allows these cables to fit in tight spaces and can reduce the length of cable required in many applications.

  • Scanner Probe

    RFS set - Langer EMV-Technik GmbH

    The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly. They document the whole image of the device under test`s near field. The scanner probes have a sheath current attenuation and are electrically shielded. They are connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. The measuring signal can be increased with PA 203 or PA 303 preamplifier. On request RFS, LFS and XFS scanner probes can be produced.

  • Test Bench for Starters and Alternators

    MS002 COM - MSG Equipment

    A high power multifunctional test bench includes the following diagnostic functions: diagnostics of starters, alternators and voltage regulators without applying any additional measuring devices. The test bench was invented on the basis of the requirements of modern service stations: construction implies mounting of majority of units without using additional fixing elements. The bench tests units of 12V and 24V; diagnoses the latest alternators and voltage regulators, which are controlled by car ECU; has ports to connect alternators of different brands and manufacturers: COM (LIN, BSS), P-D, DFM, D+, RLO, C, SIG. Diagnostics is carried out through load simulation of car consumers, change of rotation speed, sending of control signals (external control alternators), tracking of electrical characteristic. Testing results are transmitted to LCD display real-time. Testing modes are switched with membrane keyboard on the control panel of the test bench. The selected mode is lightened with the corresponding indicator.The equipment carries out testing of different alternators under load up to 200A. Power supply is single-phase 380V.

  • PXI-2549, 2.7 GHz, 50 Ω, Dual-Terminated SPDT PXI RF Relay Module

    778572-49 - NI

    2.7 GHz, 50 Ω, Dual-Terminated SPDT PXI RF Relay Module - The PXI‑2549 is a general-purpose single‑pole double‑throw (SPDT) switch module. You can use it to add flexibility to your switch network or to maintain uniform signal paths across multiple channels when building high‑channel‑count multiplexers. The PXI‑2549 termination resistors minimize reflections on open channels and protect your source or device under test from damage. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • 12 Channels 1.0 ~ 17.0 Gb/s (200Gbps) Pulse Pattern Generator and Error Detector

    CA9806-12 - UC Instruments, Corp.

    The UC INSTRUEMNTS CA9806-12 is a highp erformance, flexible 12 channels Pulse Pattern Generator and Error Detector that can operate from 1.0 to 17.0 Gb/s (200 G). It is combined with three sets CA9806 4 CH 1.0 to 17.0 Gbps Pulse Pattern Generator and Error Detector that incorporates an external one by 4 rate clock synthesizer. Its small size allows it to be placed close to the device under test, it can also be placed further away using the TX driver pre and post emphasis controls features to compensate for cable and interconnect losses. It also has a non destructive, integrated eye outline capture feature along with a quick eye height and width measurement capability. Build-in 8.5 ~ 15 Gb/s eye diagram testing function.

  • Automatic Calibration Module

    ACM4509 - Copper Mountain Technologies

    ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Automatic Calibration Module

    ACM2509 - Copper Mountain Technologies

    ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Automatic Calibration Module

    ACM2520 - Copper Mountain Technologies

    ACM2520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full 2-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • PXI-2559, 2.5 GHz, 75 Ω, Dual-Terminated SPDT PXI RF Relay Module

    778572-59 - NI

    2.5 GHz, 75 Ω, Dual-Terminated SPDT PXI RF Relay Module - The PXI‑2559 is a general-purpose switch module featuring two independently terminated single‑pole double‑throw (SPDT) relays. You can use it to add flexibility to your video switch network or to maintain uniform signal paths across multiple channels when building high-channel-count multiplexers. The PXI‑2559 termination resistors minimize reflections on open channels and protect your source or device under test from damage. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • Bulk Current Monitoring Probe

    MP-50 - FRANKONIA GmbH

    The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.