Showing results: 151 - 165 of 177 items found.

  • Petroleum Testing Solutions

    Labodam

    Acid andalkali testers, aniline test equipment, automatic bomb calorimeters, automatic dielectric tester, closed cup flash point tester, demulsibility characteristics tester, density tester, distillation tester, dropping point tester, engler viscometer, existent gum tester, kinematics viscometer, low temperature tester, octant number and cetane number tester, open cup flash point tester, oxidation stability tester, oxygen bomb calorimeter, penetrometer, residue carbon, rotational viscometer, rust and corrosion tester, specific gravity tester, sulphur content tester, vapor pressure, water content tester.

  • RFID Chamber

    Cuming-Lehman Chambers

    – 80dB RF shielded enclosure (inside dim.- 5’ high x 5’ wide x 7’ long)– Fabrication, Construction, and Transportation– Free standing shielded enclosure design including structural support system– Enclosure will be installed over a continuous 1/8″ dielectric underlay and polyethylene vapor barrier– Modular wood-core panel construction– Bulkhead connector panel – (1) 12” x 12”– RF shielded doors – (2) 2’ x 2’– One (1) Antenna Sinclair Model SP-440-SF2SNF– Shield test per IEEE –STD 299- supersedes MIL-STD-285 (Tested @ 1 GHz)– RAM

  • High Voltage Surge Testers

    HVST - Test Electronics

    The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. This voltage is displayed on an oscilloscope and recorded on the Pass/ Fail LED latch monitor. This voltage will be accurate despite the impedance of the winding being tested. The insulation system can be tested way above the operating voltage because of the brief duration of the applied voltage test pulse. This allows faults to be detected long before they become apparent at operating conditions.

  • AC Hipot w/ Ground Bond Test Capability

    HypotULTRA® Series - Associated Research

    In a world where data is king, HypotUTLRA improves traceability with on-board data storage and allows you to automate hipot testing with a variety of communication interfaces. Increase efficiency with our direct barcode scanner connection and intuitive touch screen interface. Models 7804 and 7854 are a 4-in-1 solution with the addition of 40A AC Ground Bond test capability added to HypotULTRA's already impressive feature list. HypotULTRA is a dielectric analyzer designed to take your production line to the next level.

  • Digital H.V. Insulation Tester(10kV)

    6310 IN - Standard Electric Works Co., Ltd

    ● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 20 TΩ● 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on

  • Digital H.V. Insulation Tester(5kV)

    6305A IN - Standard Electric Works Co., Ltd

    ● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on

  • Digital H.V. Insulation Tester(5kV)

    6305 IN - Standard Electric Works Co., Ltd

    ● High contrast OLED display● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display

  • Digital H.V. Insulation Tester(5kV)

    6304 IN - Standard Electric Works Co., Ltd

    ● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 1.9mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display

  • High-Voltage Test Hood

    LX-HVE600 - LXinstruments GmbH

    The bright test room with a ball-bearing cover is designed for high production quantities. Thanks to the easily exchangeable exchangeable plate, retrofitting for testing different products is also a simple task. Product properties: External dimensions (W * D * H) approx. 640 * 716 * 640mm Usable test space (W * D * H) approx. 450 * 500 * 460mm Contacting Installation space approx. 100mm high under removable plate Dielectric strength min 10kV Application area up to 2000m above sea level Pollution degree 1 without condensation Standard conformity EN50191 / EN61010-1 Schmersal safety switch AZM161 with guard locking Lid is supported by ball bearings for high number of cycles, the bearings can be easily exchanged for servicing Optionally available, Not included in the price: - Red / green signal light - Mobile substructure trolley with 19 "

  • High-Voltage Test Hood

    HVE900 - LXinstruments GmbH

    The large, bright test room with a ball-bearing cover is designed for high production quantities. Thanks to the easily exchangeable exchangeable plate, retrofitting for testing different products is also a simple task. Product properties: External dimensions (W * D * H) approx. 940 * 716 * 640mm Usable test space (W * D * H) approx. 750 * 500 * 460mm Contacting Installation space approx. 100mm high under removable plate Dielectric strength min 10kV Application area up to 2000m above sea level Pollution degree 1 without condensation Standard conformity EN50191 / EN61010-1 Schmersal safety switch AZM161 with guard locking Lid is supported by ball bearings for high number of cycles, the bearings can be easily exchanged for servicing Optionally available, Not included in the price: - Red / green signal light - Mobile substructure trolley with 19 "

  • H.V. Insulation Testers (OLED Display 1kV up)

    6213A IN-M - Standard Electric Works Co., Ltd

    ● High contrast OLED display● Designed for viewing in the dark, for mining industry.● Wide viewing angle.● Smart microprocessor-controlled.● 2 x 16 characters, large, High Contrast, Intelligent OLED Display.● Automatically calculates Dielectric Absorption Ratio (DAR).● Automatically calculates Polarization Index (PI).● Insulation resistance; Auto-ranging on all ranges.● Ener-Save● Bar graph indicates test voltage. Rise and decay can be obeserved.● External voltage presence warning (>500Vac or Vdc)● Overload protection● Low battery indicator (real time battery voltage mearsurement)● Measures insulation time duration of the test● Better than 10% accuracy on all ranges● Auto-off

  • Digital 10kV High Voltage Insulation Tester

    4310 IN - Standard Electric Works Co., Ltd

    • Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display

  • Digital 5kV High Voltage Insulation Tester

    4305 IN - Standard Electric Works Co., Ltd

    • Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 1 TΩ • 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display

  • Electrostatic Discharge Testing / ESD Testing

    Keystone Compliance

    Electrostatic discharge testing, also known as ESD testing is an essential test for many product. Electrostatic discharge can cause a number of problems including but not limited to mechanical failures, coal dust explosions, fuel vapor explosions and bodily injury. ESD is the sudden transfer of electricity between to electrically charged objects. This electrostatic transfer can be caused by contact, dielectric breakdown or an electrical short. ESD testing simulates various electrostatic impacts that equipment might experience either during transit or operation. The impact of electrostatic discharge can be significant whether the ESD even is so slight that is undetectable by hearing or sight or as spectacular as electrical sparks or lightning. An electrostatic discharge test determines whether a product is in compliance with its ESD protective area and procedures. Electronics manufacturers must identify ESD-reducing measures when their products are either susceptible to ESD or likely to create ESD. These measures can include establishing electrostatic protective areas that are free of static, controlling humidity, using measures to eliminate charging such as avoiding highly charging materials and taking steps to remove static such as grounding human workers or requiring antistatic devices. An ESD test confirms that the equipment correctly operates per the test requirement and the manufacturer’s operating procedures.

  • Digital H.V. Insulation Tester(15kV)

    7016 IN - Standard Electric Works Co., Ltd

    ● Protection class: IP66 (Lid closed)● Test insulation resistance up to 30TΩ (30000GΩ).● Short-circuit current up to 5mA● Microprocessor controlled.● 30 insulation test voltages : 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV● AC/DC voltmeter (600V).● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) : 1~30 minutes● Auto-off.● Calendar.● Optical USB to RS-232 data transmission.● 200 measurement results can be saved in the memory and recalled on the display.● Safety standard : EN 61010-1 CAT IV 600V EN 61010-2-030 EN 61326-1