Showing results: 406 - 420 of 533 items found.
-
Techimp HQ S.r.L
TEM antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset (like MV switchgears or LV and MV induction motors fed by power electronic impulses). It is a broadband antenna with a flat response which makes TEM suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes TEM the optimal sensor for direct installation on medium voltage Switchgears and motors. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces.
-
Chroma ATE Inc.
Regenerative battery energy dischargeEnergy savingEnvironment protectionLow heat generateChannels paralleled for higher currentsCharge / discharge mode (CC, CV, CP) Constant current Constant voltage Constant powerDriving cycle simulationHigh precision measurement accuracyFast current conversionSmooth current without over shootTesting data analysis functionData recovery protection (after power failure)Independent protection of multi-channelBMS data recordingThermal chamber control integration
-
Spark P3 -
Manta Test Systems
Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.
-
Megger Group Ltd.
Handheld online PD substation surveying system. The UHF PD Detector is the ideal tool for quick, non-invasive surveys in MV and HV substations and should be part of the toolkit for all maintenance and service teams. Due to its high measurement bandwidth, the UHF method provides accurate local online partial discharge (PD) measurements on HV components such as cable end-terminations, surge arrestors, voltage transformers and isolators.
-
Bloomy Controls, Inc.
A Battery Management System (BMS) is an embedded unit performing critical battery functions, including cell monitoring and balancing, pack charge and discharge control, safety, and communications. The BMS must be tested early in development to optimize control algorithms, as well as during manufacturing to ensure reliable functionality. Bloomy’s family of BMS test systems provides a consistent platform for engineers to bring a BMS to market faster, and more reliably.
-
Chroma 11210 -
Chroma Systems Solutions, Inc.
Chroma 11210 battery cell insulation tester is an instrument used for accurately measuring leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials. In addition to standard LC/IR measurement, the 11210 has a unique function that detects partial discharge (PD) or flashover that may have occurred inside the insulation material during the high voltage insulation testing process.
-
Xiamen WinAck Battery Technology Co., Ltd.
The battery cycle life tester is a high-precisionsystem designed specifically for the battery cell charge and discharge testing.It is suitable for the battery cell cycle test, battery cell charge anddischarge aging test, battery cell performance test, battery cell capacitydetection test, battery cell IR test, deep-discharging test, function test ofhigh-power lithium-ion battery cells, such as EV battery module, ES batterymodule, super capacitor…
-
Guangdong Bell Experiment Equipment Co.,Ltd
Walk in Chamber for Altitude Simulated Test Relative Standard test requirementsTest Object: battery pack and systemTest Conditions: Altitude 4000m or the equate air pressure condition, atroom temperature.The test objects stay in the test condition as Item 2 for 5 hours.Subject the test object to 1C(no more than 400A) constant current discharge until reaching the cutoff condition.After testing, observe for 2h under the room temperature.
-
CDN-5810 -
Shanghai Sanki Electronic Industries Co., Ltd.
CDN-5810 signal line/data line coupling decoupling network, unshielded symmetrical communication line suitable for surge pulses and ringing wave pulses, designed according to Figure 10 of the new standard IEC61000-4-5.Ed3. It also satisfies ringing Figure 10 requirements of wave standard IEC61000-4-12.Ed2. According to the characteristics of the line, the pulse coupling can be realized by gas discharge tube, capacitor, diode and other different methods.
-
380320 -
Extech Instruments Corporation
The 380320 is an Analog Insulation Tester with a large, easy to read analog display. Featuring a live circuit warning which displays the actual AC voltage measurement, Automatic discharge circuit, Lock Power On feature for extended test times, and Insulation resistance up to 400MΩ. Complete with heavy duty test leads, alligator clip test lead, 6 x AA batteries, hanging strap and hard carrying case.
-
Evans Analytical Group®
EAG is an industry leader in ESD testing (Electrostatic Discharge) and Latch up testing. Our highly experienced engineering team use their industry leading knowledge and years or real world experience of the latest semiconductor technologies, circuit design, and device physics to optimize our customer's ESD and latch-up results. Human Body Model (HBM) and Machine Model (MM), Charged Device Model (CDM), Latch-up, Transmission Line Pulse (TLP).
-
12-0200 -
Associated Equipment Corp.
Vehicle Battery Systems fitted to modern cars require a complex system to control and maintain the best charge and discharge rates which not only ensures the longest in service life but also that systems such as Stop/Start operate correctly. The 12-0200 gives the operator access to all the functions complicated and time-consuming manufacturer scan tools have to perform the same function but in a fraction of the time. On average the total time required by the technician to reset a system will be 30 seconds.
-
ET Power Systems Ltd.
Electronic test engineers use a variety of precision instruments for R&D, vendor verification, and production testing. ETPS can supply a number of general test instruments that can be used in stand alone mode or automated for high throughput testing. Dedicated battery test systems with automatic charge and discharge modes with data logging are available. The standard 16 and 32 channel systems have range up to 5VDC ensuring their suitability for a wide variety of cells.
-
CDN-5809 -
Shanghai Sanki Electronic Industries Co., Ltd.
CDN-5809 signal line/data line coupling decoupling network, unshielded asymmetric communication line suitable for surge pulses and ringing wave pulses, designed according to Figure 9 of the new standard IEC61000-4-5.Ed3. It also satisfies vibration Figure 9 of the ring wave standard IEC61000-4-12Ed2 requires unshielded asymmetry. According to the characteristics of the line, the pulse coupling can be realized by gas discharge tube, capacitor, diode and other different methods.
-
pE-300white -
CoolLED Ltd.
CoolLED's pE-300white offers intense, broad-spectrum LED illumination for imaging most common fluorescent stains. The pE-300white Light Source can be fitted directly to the microscope or specified with a liquid light guide. The system is a mercury-free alternative that is safer, more controllable, and repeatable than conventional high-pressure gas discharge illuminators. Spectral coverage is from the UV (DAPI excitation) to the Red region (Cy5 excitation). The system is perfect for hospital and regular research laboratory environments.