Filter Results By:

Products

Applications

Manufacturers

EHF

extremely High Frequency in the range of 30 to 300 gigahertz.


Showing results 1 - 15 of 735 products found.

  • Handheld Digital Spectrum Analyzer

    915M - Seeed Technology Inc.

    Frequency band: 910-920 MHz (enhanced to 900-930 MHz if an Expansion Module is connected)Frequency span: 112 KHz-10 MHz(enhanced to 30 MHz if an Expansion Module is connected)Graphics LCD 128x64 pixels, great visibility outdoorsPC Windows client supports Windows XP/Vista/Win7 both 32 and 64bitsBacklight for great indoor visibilityStandard SMA 50 ohms connector, a matching antenna is includedAmplitude resolution: 0.5dBmDynamic range: -115dBm to 0dBmAbsolute Max input power: +5dBmAverage noise level (typical): -110dBmRF Generator amplitude: 0dBm to 20dBmFrequency stability and accuracy (typical): +-10ppmAmplitude stability and accuracy (typical): +-3dBmFrequency resolution: 1KhzResolution bandwidth (RBW): automatic 2.6Khz to 80KhzWeight: 185gSize: 113x70x25 mm

  • Handheld Digital Spectrum Analyzer

    WSUB1G - Seeed Technology Inc.

    Frequency band: 240 - 960 MHzFrequency span: 112KHz - 100MHzGraphics LCD 128x64 pixels, great visibility outdoorsPC Windows client supports Windows XP/Vista/Win7 both 32 and 64bitsBacklight for great indoor visibilityStandard SMA 50 ohms connector, wideband Nagoya NA-773 telescopic antenna includedAmplitude resolution: 0.5dBmDynamic range: -115dBm to 0dBmAbsolute Max input power: +5dBmAverage noise level (typical): -110dBmFrequency stability and accuracy (typical): +-10ppmAmplitude stability and accuracy (typical): +-3dBmFrequency resolution: 1KhzResolution bandwidth (RBW): automatic 2.6Khz to 600KhzWeight: 185gSize: 113x70x25 mm

  • Handheld Digital Spectrum Analyzer,

    Seeed Technology Inc.

    Frequency band: 240 - 960 MHz and 2.35 – 2.55 GHzFrequency span: 112KHz - 100MHzGraphics LCD 128x64 pixels, great visibility outdoorsPC Windows client supports Windows XP/Vista/Win7 both 32 and 64bitsBacklight for great indoor visibility2 standard SMA 50 ohms connector, one for Sub-GHz wideband Nagoya NA-773 telescopic antenna included and another one for 2.4GHz band with helical antenna included.Amplitude resolution: 0.5dBmDynamic range: -115dBm to 0dBmAbsolute Max input power: +5dBmAverage noise level (typical): -110dBm2.4GHz RF Generator amplitude: -30dBm to +1dBmFrequency stability and accuracy (typical): +-10ppmAmplitude stability and accuracy (typical): +-3dBmFrequency resolution: 1KhzResolution bandwidth (RBW): automatic 2.6Khz to 600KhzWeight: 185gSize: 113x70x25 mm

  • Handheld Radio Frequency Counter

    FC1000 Series - ACECO Electronics Corp.

    A superb value low cost frequency counter Frequency range: 10 MHz - 3 GHz Weight: 210g Case: 80 mm * 68 mm * 31 mm stamped aluminum with black anodized finish Battery: Internal 4 * AA 600 mAH NiCd pack 8 digit liquid Crystal Display with 100 Hz resolution Low power consumption (Average 6 hour battery life)

  • Handheld Radio Frequency Finder

    FC3000 Series - ACECO Electronics Corp.

    The latest advance in RF finderFrequency range: 10 MHz - 3 GHzWeight: 210gCase: 80 mm * 68 mm * 31 mm stamped aluminum with black anodized finishBattery: Internal 4 * AA 600 mAH NiCd pack7 digit liquid Crystal Display with 1 KHz resolutionLow power consumption (Average 6 hour battery life)Hold switch to lock displayDigital filter prevents display of random noiseLow battery indicatorUltra sensitive synchronous detector 16 section bargraph to show RF signal strengthAutomatically holds and tunes ICOM CI-V or AOR receiversMeasure frequency and period

  • Handheld Signal Generator

    P12 - kronback tracers

    - Two programmable agile pilot tones- Straightforward, heavy-duty hardware- Recall of predefined presets- Frequency range: 3-1218 MHz- Dynamic range: > 50 dBc- Level: 100 dBuV @ 3-204 MHz; 90 dBuV @ 204-1218 MHz- Compact size: 23 x 83 x 140 mm

  • Handheld X-Ray Imager

    HBI-120 - Heuresis Corporation

    Heuresis’ HBI-120 is a rugged, ergonomic, handheld backscatter x-ray instrument that enables users to quickly and cost-effectively find concealed explosives, narcotics and other contraband, even through 12- gauge (over 2 mm thick) steel — more than twice the thickness of typical motor-vehicle body panels — with none of the limitations of portable transmission x-ray systems. The HBI-120 weighs only 6.6 lbs. (3.0 kg) and images objects with a miniaturized, internal 120 keV x-ray generator that makes a raster-scanning pencil beam of x-rays to scan objects of interest. As the handheld HBI-120 is moved over the object, a 2- dimensional backscatter x-ray image of the object is displayed in real-time on HBI-120's high-resolution transflective LCD touchscreen and saved in the instrument’s memory.

  • Helical Antennas

    Schwarzbeck Mess Elektronik

    Helical antenna750 - 1050 MHzleft hand circular polarisation (LHCP)gain: 11 dBic22 mm tubeN-jack

  • Explosion-Proof Differential Pressure Switch

    H3 - Dwyer Instruments Inc.

    Explosion-proof, heavy duty, industrial unit has patented and unique new design which provides sensitivity to differential pressures as low as 10 inches of water (254 mm w.c.), yet handles total pressure of 1500 psi (103 bar). Unlike common differential pressure switches that use a piston-type motion transfer, the Series H3 utilizes a rotary motion transfer shaft that prevents a change in total pressure from causing a setpoint shift.

  • Femtosecond Optical Parametric Amplifier

    CDP 2017 - CDP Systems Corp.

    *30% conversion efficiency from pump pulse to parametric radiation* Wavelength conversion for ExciPro, TAPPIR, FOG 100-DA* Wavelength conversion options for wavelength tuning from 240 nm to 16 mm* Pump wavelength: 800 20 nm* Pump pulse energy: 0.4 J 1.0 J* Pump pulse repetition rate: 50 Hz 5 kHz* Pump pulse duration: < 100 fs

  • Ferrite Meter

    MF300F+ - DIVERSE Technologies

    The Diverse Ferrite meter MF300F+ measures the Ferrite number (FN) of austenitic and duplex stainless steel weld material. It has a probe that is sensitive to ferrite content in a 10 mm area to a depth of approximately 1 mm. The instrument is calibrated using the secondary world standards held at The Welding Institute. All 16 standards are used in the calibration giving an instrument with a measurement range from 0 to 115 FN.

  • FIber Based Solar Simulator

    Sciencetech, Inc.

    Provides up to 12 suns class B non-uniformity over a 12.5 mm diameter with the A4 Light Line and class C uniformity can be achieved over 18mm diameter both with a working distance of 25 cm. Provides up to 4 suns class B non-uniformity over a 12.5 mm diameter with the A1 Light Line with a working distance of 25 cm.

  • Final Test Manipulators

    esmo AG

    for test heads up to 250 kg / 550 lbsfinal test dedicatedhandler docking prolowest possible floor loadeasy motion in z-direction to facilitate docking processforce feedback control feature ensuring operator safety and protecting equipment during set-upactive cable managementdurable and robust designoptimized footprint for various test heads580 mm linear in/out motion for handler service access160 mm linear side-to-side feature270 column pivoting featurenumerous additional, unique features for individual set-up requirements

  • Flatness Accessory Kit

    55282A - Keysight Technologies

    The 55282A Flatness Accessory Kit is composed of an 10759A Footspacing Kit and two 10773A Flatness Mirrors. The footspacing kit provides three precision baseplates, with 50.8 mm (2 in), 101.6 mm (4 in), and 152.4 mm (6 in) pad spacing respectively, that minimize the grid setup and data accumulation time required for plate calibration. The flatness mirrors provide 100 percent reflectance and turn the direction of an incoming laser beam 90 degrees.

  • Flatness Mirror

    10773A - Keysight Technologies

    The Keysight 10773A Flatness Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror, used in the 5530 Laser Calibration System, measures flatness in applications such as surface plate calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10773A.