Showing results: 1 - 15 of 16 items found.
-
6221 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Indicates phase rotation.● Indicates phase presence.● Tests for disconnection sensitivity.● Indicates battery status.● Tests for disconnection time.● Measures voltage phase to earth.● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Very low consumption.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Led indication of Voltage on ELCB.● Phase rotation and presence does not require battery to indicate.● EN 61010-1 CAT III 550V. EN 61326-1
-
6221 EL-M -
Standard Electric Works Co., Ltd
● High contrast OLED display.● Designed for viewing in the dark, for mining industry.● Microprocessor-controlled.● Indicates phase rotation● Indicates phase presence● TEST for disconnection sensitivity● Battery status indicator● Measures Voltage Phase to Earth● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Phase rotation and presence does not require battery to indicate.
-
6220 EL -
Standard Electric Works Co., Ltd
● Microprocessor technology ensures high performance accuracy and reliability.● Fully programmable via tactile key pad.● Direct readout of disconnection, time or current.● Voltage measured during test.● Housed in a heavy duty carry case.● Suitable for all industrial, mining and domestic environments.● Display can be customized for special orders.● Indicate voltage and trip Current/Time.● Use binary principle.● True resistor switching.
-
810 EL -
Standard Electric Works Co., Ltd
● Wiring check.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● Sense automatically 50 or 60 Hz.● No battery required.● Simple operation.● Current injected in phase with the voltage.● Fused.● Wide operating voltage (195Vac to 265Vac).● Other voltage optional (110V).● Robust.
-
1810 EL -
Standard Electric Works Co., Ltd
● Taut Band movement.● Simple operation.● Wiring check.● Robust.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● No battery required.● Sense automatically 50 or 60 Hz.● Current injected in phase with the voltage.● Other voltage optional (110V).
-
TEL1-x Series -
Standard Electric Works Co., Ltd
● The TEL1 is the Basic Test Equipment an Electrician cannot do without. TEL1 is a Dual Function Test Instrument utilized to Verify Electrical Wiring Connections and the Functioning of Earth Leakage / Residual Current Detectors devices by forcing the ELCB/RCD to trip.
-
KM 1812 EL -
Kusam Electrical Industries Limited
* 2 Lines x 16 Characters L.C.D.* Very Low Power Consumption.* Microprocessor Controlled.* Menu Driven.* Accurate digital readout of disconnection Time.
-
2820 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Operating voltage 100-450V L-E.● Rated current 999mA, at 317V AC/50Hz.● Checks ELCB trip time and trip point (sensitivity).● Auto off and auto ranging.● Phase angle selection(0° / 180°).● Indicates tripping phase angle.● Impact resistant enclosure.● Over temperature shut-down.● Transient protection.● Suitable for heavy industrial use.● Fused.
-
1811 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Suitable for industrial applications.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto off and off override.● Polarity Trip indicator (Positive of Negative Phase).
-
1813 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● Suitable for domestic version.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Automatic data hold function.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● 60Hz available.
-
2712 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.
-
1812 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto-off and off override.● Polarity Trip indicator (Positive of Negative Phase).● Wiring polarity indicator.● Measure voltage and frequency between Line and Earth before testing.
-
PXIe-1149.5 -
Corelis, Inc.
The Corelis PXIe-1149.5 is a versatile, multi-mode instrument for interfacing with MTM-Bus modules. The PXIe-1149.5 adds MTM-Bus master, slave, and monitoring with full IEEE-1149.5 electrical and protocol compatibility with a standard PXIe interface for convenient integration into any Test Program Set (TPS).
-
ABex AM-300 Controller -
Konrad Technologies GmbH
The ABex system controller ABex AM-300 is required to control the analog bus of a ABex chassis. It is used as an interconnection bridge between PXI and ABex backplane.In addition it features a whole bunch of additional functionality. Despite the 96 open drain outputs it has galvanically isolated IOs, and communication interfaces.
-
8025 LP -
Standard Electric Works Co., Ltd
● Battery is not used.● 3 ½ digit LCD (2000-count).● Backlight function.● 15mA loop measurement which will not trip ELCBs.● Convenient and easier for users to measure the loop impedance directly without bypassing the wires.● Wiring check function.● Over temperature protection.● Over voltage protection.● Built-in voltmeter.● Built-in earth tester.● Built-in loop/psc tester.● Safety standard : EN 61010-1 CAT III 300V EN 61326-1