410130132 -
Virginia Panel Corporation
This model i2 MX includes 2 Hybrid Module inserts. Each module insert includes 8 Mini Power/Coax and 8 TriPaddle positions. The XL-sized backshell allows for a greater cable bend radius and large cable exit which accommodates larger, high speed cables or a high volume of twisted pair combinations. The max cable bundle eff diameter= 1.67".
-
WS6-1000XME-W5 -
TEAM SOLUTIONS, INC.
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.
-
WS6-1000XMES-W5 -
TEAM SOLUTIONS, INC.
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.
-
HS6-DIFF-1000XMEG-W5 -
TEAM SOLUTIONS, INC.
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
HS6-DIFF-1000XMEGS-W -
TEAM SOLUTIONS, INC.
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEGS EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
EMI Analyst™ -
EMI Software llc
EMI Analyst (U.S. Patent # 7,222,033) is the premier tool for ascertaining compliance with EMI requirements imposed by regulatory agencies.EMI Analyst is an electromagnetic interference analysis program that combines all four facets of EMI analysis into a single design package.
-
CKC Laboratories, Inc.
EMI is emitted radiation and its effects – a phenomenon. EMC is a device’s ability to limit the levels of unintentionally emitted EMI (that can harm other devices) and also a device’s ability to operate normally when subjected to EMI. Therefore, EMC testing seeks to ensure that a product possesses the characteristic of Electromagnetic Compatibility (EMC): the ability to limit creation of EMI (Electromagnetic interference) and the ability to operate properly when subjected to EMI. Stated differently, EMC testing measures the level of EMI control found in a device, and therefore helps to ensure that unwanted effects are prevented.
-
-
Smiths Interconnect
Filter connector series includes EMI/ EMP/ESD circular, ARINC, D-subminiature and micro-D connector styles. They can be combined with high energy TVS diode technology to achieve lightning and EMP transient protection. Smiths Interconnect's EMI filter connectors use multi-layer ceramic capacitor arrays together with inductive materials to realize robust, high performance low pass filter networks. Where required, transient protection can be combined with EMI /RFI filtering to provide maximum protection. The diodes as well as the EMI filter are packaged separately so the construction of the connector remains modular.
-
PW-3032R -
PINTEK Electronics
*Toroidal Transformer*Low EMI & High EMS*Very Low Ripple & Noise*30V/3A+5V/3A Dual output.*<0.3m Vrms Ripple & Noise(C.V.)*<2m Arms Ripple & Noise(C.C.)*Low EMI & High EMS.*Dual Display.
-
EMI-360 -
Peritec Corp.
3D RF Noise Measurement System EMI-360 to realize the new EMC measurement.EMC measurement is possible to realize a low-cost and time reduction.
-
LBA Group, Inc
EMI (Electromagnetic Interference) is often used interchangeably with RFI (Radio Frequency Interference). However, EMI can be any frequency of electromagnetic noise, whereas RFI is a relatively narrow range of electromagnetic noise on the EM spectrum. EMI Shielding can be used to mitigate electric and magnetic radiation across various spaces. Radio Frequency (RF) Shielding can be used to mitigate RFI with specifically designed enclosures that can block RFI. As well, RF Shielding can include application of RF Shielding paints, fabrics, and other materials.
-
KH23101 -
Beijing KeHuan Century EMC Technology Co,.LTD
The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.
-
Alpha Lab, Inc.
The Line EMI Meter measures electromagnetic interference in a single-phase AC power line. It plugs into a wall outlet (mains socket) and requires no battery. It immediately displays total line noise in millivolts (range 1999 mV, resolution 1 mV) in the frequency range 10 KHz 10 MHz (the frequency limits at which sensitivity is of the maximum sensitivity). A speaker plays the sound of the EMI, amplitude demodulated, in order to identify the EMI source (such as an AM or shortwave radio station vs. a motor vs. an electric arc).
-
Holding Informtest
Infrastructure housing for instrument cards typically containing a power supply, cooling fans and emi shielding.