Filter Results By:
Products
Applications
Manufacturers
Electro-Chemical
chemical action when combined with electricity.
- PalmSens BV
product
Potentiostat / Galvanostat / Impedance Analyzer
PalmSens4
PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS). The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution and low noise. This instrument is a complete laboratory instrument but its compact and rugged design makes it also ideal for field work.
-
product
Cell Stand
CS-3A
The CS-3A Cell Stand is adopted with CHI series Electrochemical Analyzers and other apparatus directly. The cell is enclosed in a Faraday cage to reduce electrical interference. A built-in gas control allows purging a sample. Gas line is provided to purge next sample, while analyzing the present sample separately, thus increasing productivity. Magnetic stirrer allows for controlling the mixing of the sample for experiments requiring mass transport of electrolyte or analyte to the electrode surface. Cell top positioner with detachable cell cap allows easy removal and replacement of the cell vial as well as the electrodes for rinsing, cleaning, and replacement.
-
product
CellTest Multichannel Potentiostat
Simultaneous Electrochemical Impedance Spectroscopy (EIS) tests can be run on multiple cells by connecting Solartron 1455A/1451A series frequency response analyzer (FRA) modules to the 1470E. These FRAs can operate in single sine correlation or multi-sine / Fast Fourier Transform (FFT) analysis mode, providing the ultimate in speed, precision and accuracy. The 1455A FRA provides high performance impedance measurements over the frequency range 10 μHz to 1 MHz, while the 1451A FRA operates from 10 μHz to 100 kHz.
-
product
DigiElch Electrochemical Simulation Software
DigiElch 8 from ElchSoft is an electrochemical simulation program for a wide variety of systems involving charge transfer reactions, adsorption, and charge-coupled chemical reactions such as proton-coupled electron-transfer (PCET). A demonstration version of DigiElch 8 is available.
-
product
DS Sensor
Z-Gard DS Sensor
The Z-Gard DS Sensor is designed to detect the presence of carbon monoxide and nitrogen dioxide gases in parking garages, vehicle storage areas or wherever else these two toxic gases could be found. These sensors employ electrochemical sensors which generate a representative output signal proportional to the calibrated operating range.
-
product
EIS Interface (Electrochemical Impedance Spectroscopy)
BATT470m
The BATT470m electrochemical impedance analysis interface (EIS) provides an easy to use battery/cell impedance test platform for the electrochemical industry. Utilizing the highly accurate PSM3750 frequency response analyzer from N4L, the BATT470 provides impedance measurement of batteries/cells up to 100V DC. With a frequency range of 100mHz to 1MHz, the BATT470m covers a wide range of applications. Our software package - PSMComm2, featuring “EIS” mode, displays the in-phase and quadrature impedance of the cell in Nyquist form as well as overall impedance (Z), in bode form.
-
product
Electrochemical Detector
800D
The Model 800C series is designed for electrochemical detection. This instrument can be used for monitoring the current passing through a flow cell in liquid chromatography/electrochemistry and in-flow injection analysis, as well as other electroanalytical applications.
-
product
Electrochemical Measurements
A portable pH-meter from CHAUVIN ARNOUX is ideal for mobile applications: in the field, in the laboratory or in production. It can be used for quick, accurate, professional measurements of pH, Redox potential and temperature.
-
product
Electrochemical Workstations
Besides a potentiostat / galvanostat all our electrochemical workstations include also a frequency response analyzer unit (FRA) in their basic configuration. This makes each of our electrochemical workstations a highly versatile basis equipment for a multitude of electrochemical investigation methods on batteries, accumulators and fuel cells as well as on high impedance objects such as coatings and laminates. Due to their hardware extensions slots our instruments can be extended to multi purpose data acquisition and control test stands.
-
product
Electrochemistry
Modular Line
The Modular Line of instruments consists of a range of instruments to suit any requirements in electrochemical research, from low to high voltage and from low to high current.
-
product
Electrochemistry Research Equipment
Our electrochemical equipment will help your group achieve laboratory and research goals. The best-selling EZstat Pro potentiostat/galvanostat can run cyclic voltammetry, electrochemical impedance spectroscopy (EIS), battery tests, and high speed galvanostatic intermittent titration technique (GITT). The EZstat HV potentiostat delivers up to 1 amp at 25 volts. The Powerstat comes in two configurations (5 amp vs 20 amp). The Duostat bipotentiostat can operate rotating ring-disk electrode experiments. The Arraystat and ArrayPGstat feature multichannel operation with different customizable options (current range, number of channels, etc.).
-
product
Flow Cell Kit
QCMT
The quartz crystal microbalance (QCM) technique under electrochemical frequency is very useful to determine many compounds such as metal proteins, metal ions and thiol-conjugated oligonucleotides.
-
product
Formaldehyde Meter
-Backlit LCD displays simultaneously formaldehyde (HCHO), temperature, humidity, easy to monitor.-Occupational safety monitoring shows TWA (8 hours) and STEL (15 mins).-Use high-precision electrochemical sensors.-The maximum / minimum / average hold.-Stores 200 records manually.-Data hold.-Formaldehyde maximum and minimum alarm value setting.
-
product
Handheld Electrochemical Battery Analyzer
EC-Series
Global Energy Innovations, Inc.
The EC1000™ and EC2000™ are the only handheld, Multi-Frequency, ElectroChemical Battery Analyzers on the market using CELScan™ technology. This means they can report both the Electrical (Impedance & Voltage) and Chemical (Sulfation and Dryout) properties of lead acid batteries (VLA, VRLA, GEL). Other battery types (NiCd, NiMH, Lithium-Ion and others) may also be tested using the EC1000™ and EC2000™.
-
product
IDA Electrodes
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
product
Impedance Spectroscopy
NuVant EZware-EIS Software Package
The NuVant EZware-EIS software package activates Electrochemical Impedance Spectroscopy on the EZstat-Pro, Powerstat-05 and -20 potentiostat/galvanostats. EZware-EIS exports the impedance data to a file format to accommodate free third party EIS analysis software. EZware-EIS is a user-friendly interface that allows selection of the proper scanning parameters, collect the impedance spectra, display data in Nyquist and/or Bode plots and export data in the proper data format for use in EIS analysis software.
-
product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
product
Multiplexer
The Ivium Technologies electrochemical multiplexer can work individual cells with 2, 3 and 4 electrodes and a WE2 (BipotentioStat, optional). Each multiplexer has 8 channels and the multiplexer units can be stacked so that up to 64 channels can be controlled sequentially by a single potentiostat.
-
product
Oxygen Analyzer
1100 Percent Oxygen
The Neutronics 1100 Percent Oxygen Analyzer is a compact analyzer for oxygen gas measurement and process control applications. Designed for a measurement range of zero to 100% oxygen, the unit features a reliable electrochemical sensor that can be mounted remotely at the sampling point to ensure a fast response time. A flow-through mounting head allows the sensor to be horizontally or vertically mounted directly into the sampled process gas stream.
-
product
Oxygen/Combustibles Analyzer
DT3006
The Datatest Model DT3006 Oxygen/CO analyzer is a microprocessor based instrument. It has a zirconia sensor for oxygen and an electrochemical sensor for carbon monoxide. Excellent trim control and boiler safety instrument with great reliability and stability thanks to the micro controller.
-
product
Potentiostat Galvanostat
1287A
The Solartron Analytical 1287A potentiostat and galvanostat is a high accuracy, wide bandwidth instrument which offers a range of DC test capabilities. The 1287A can be coupled with a frequency response analyzer, such as the Solartron Analytical 1260A or 1255B, and ZPLOT software for AC tests such as Electrochemical Impedance Spectroscopy.
-
product
Potentiostat/Galvinostat
EZstat Pro
The EZstat Pro potentiostat/galvanostat uses a versatile menu-driven waveform generator (periodic or aperiodic) with preset battery cycling, Tafel plots, and cyclic voltammetry procedures.Users can program sequences of steps blending current and potential control with a resolution of 8 uS/point. EZstat Pro can perform electrochemical impedance spectroscopy (EIS) and uses active IR compensation. The instrument can interface with the EZpump peristaltic pump for flow batteries and fuel cells.
-
product
Potentiostat/Galvinostat Electrochemical Instuments
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
product
Radiometer Analytical Probes
Radiometer Analytical develops and manufactures an extensive range of electrochemical electrodes - combined pH, glass or reference electrodes, metal electrodes, ion-selective electrodes and conductivity cells - for every application and budget.
-
product
Reference Electrodes
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
product
Scanning Electro-chemical Microscope
920D
The scanning electrochemical microscope (SECM) was introduced in 19891 as an instrument that could examine chemistry at high resolution near interfaces. By detecting reactions that occur at a small electrode (the tip) as it is scanned in close proximity to a surface, the SECM can be employed to obtain chemical reactivity images of surfaces and quantitative measurements of reaction rates.
-
product
Single Channel Potentiostats
PARSTAT Series
The PARSTAT-series of potentiostats is defined by offering superior performance as standard. The PARSTAT4000A and PARSTAT3000A complement each other.Both of these single channel potentiostats operate in VersaStudio software with all techniques available, including Electrochemical Impedance Spectroscopy up to high frequency.
-
product
Single Channel Potentiostats
VersaSTAT Series
This family of instruments combines our option-based hardware and software platforms to create the most popular line of potentiostats. Introduced for the majority of researchers doing typical electrochemical experiments, this entire series gained a key improvement in 2018. As of August 1st, 2018, all VersaSTAT models have ± 2 Amp capability standard. Users can now study larger samples at faster rates.