Filter Results By:
Products
Applications
Manufacturers
- PalmSens BV
product
Potentiostat / Galvanostat / Impedance Analyzer
PalmSens4
PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS). The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution and low noise. This instrument is a complete laboratory instrument but its compact and rugged design makes it also ideal for field work.
-
product
Electrochemical Sensors
Electrochemical sensors are devices that provide real-time information about the composition of a system by connecting a chemically selective layer (recognition element) to an electrochemical transducer
-
product
Electrochemical Workstations
Besides a potentiostat / galvanostat all our electrochemical workstations include also a frequency response analyzer unit (FRA) in their basic configuration. This makes each of our electrochemical workstations a highly versatile basis equipment for a multitude of electrochemical investigation methods on batteries, accumulators and fuel cells as well as on high impedance objects such as coatings and laminates. Due to their hardware extensions slots our instruments can be extended to multi purpose data acquisition and control test stands.
-
product
Electrochemical Analyzer
EC Epsilon EClipse
The Epsilon EClipse™ is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. It comes with software that enables the most popular electrochemical techniques such as cyclic voltammetry, chronoamperometry, and chronopotentiometry (select Techniques below for a more complete list). The Basic Plus software can be purchased to enable pulsed voltammetry and stripping voltammetry techniques.
-
product
Electrochemical Detector
800D
The Model 800C series is designed for electrochemical detection. This instrument can be used for monitoring the current passing through a flow cell in liquid chromatography/electrochemistry and in-flow injection analysis, as well as other electroanalytical applications.
-
product
Electrochemical Analyzer/Workstation
600E
The Model 600D series is designed for general purpose electrochemical measurements. The figure below shows the block diagram of the instrument. The system contains a fast digital function generator, high speed data acquisition circuitry, potentiostat, and a galvanostat (available only in select models).
-
product
Electrochemical Converter
C800
The Control 800 series of electrochemical converters combines high performance digital conductivity and analog pH measurements with intuitive operation. It has been designed for easy integration into skids and panels to cover a wide range of bioprocess applications in both, conventional stainless steel and single-use systems.
-
product
Electrochemical Measurements
A portable pH-meter from CHAUVIN ARNOUX is ideal for mobile applications: in the field, in the laboratory or in production. It can be used for quick, accurate, professional measurements of pH, Redox potential and temperature.
-
product
Electrochemical Test System
1280Z
The Solartron Analytical 1280Z Electrochemical Test System is a complete instrument that packages the potentiostat hardware for DC and Frequency Response Analyzer (FRA) hardware for AC tests in a single compact unit.
-
product
Scanning Electro-chemical Microscope
920D
The scanning electrochemical microscope (SECM) was introduced in 19891 as an instrument that could examine chemistry at high resolution near interfaces. By detecting reactions that occur at a small electrode (the tip) as it is scanned in close proximity to a surface, the SECM can be employed to obtain chemical reactivity images of surfaces and quantitative measurements of reaction rates.
-
product
Potentiostat/Galvinostat Electrochemical Instuments
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
product
Scanning Electrochemical Systems
The VersaSCAN is a single platform capable of providing spatial resolution to both electrochemical and materials-based measurements. Each VersaSCAN is based on a common high-resolution, long-travel, closed-loop positioning system mounted to a vibration-resistant optical base. Different auxiliary pieces are mounted to the positioning system. These ancillary pieces (e.g., an electrometer, piezo vibration unit, or a laser sensor) provide functionality to the positioning system for different scanning probe experiments. VersaSTAT potentiostats and Signal Recovery Lock-in Amplifiers are integrated via ethernet control to make accurate measurements of these small signals.
-
product
Scanning Electrochemical Microscope
VS-SECM (DC And AC)
The SECM integrates a positioning system, a bipotentiostat, and an ultramicroelectrode probe or tip. The positioning system moves the probe close to the surface of the sample, within the local imaging zone. The bipotentiostat can polarize the probe only (feedback mode) or the sample and the probe independently (generator-collector mode), while measuring the resulting current(s). The probe is specially designed to have a specific tapered polish (per the RG ratio) and active radius below 100 microns. The positioning system scans the probe and charts position with measured electrochemical parameters, creating a data map of local current.
-
product
DigiElch Electrochemical Simulation Software
DigiElch 8 from ElchSoft is an electrochemical simulation program for a wide variety of systems involving charge transfer reactions, adsorption, and charge-coupled chemical reactions such as proton-coupled electron-transfer (PCET). A demonstration version of DigiElch 8 is available.
-
product
Handheld Electrochemical Battery Analyzer
EC-Series
Global Energy Innovations, Inc.
The EC1000™ and EC2000™ are the only handheld, Multi-Frequency, ElectroChemical Battery Analyzers on the market using CELScan™ technology. This means they can report both the Electrical (Impedance & Voltage) and Chemical (Sulfation and Dryout) properties of lead acid batteries (VLA, VRLA, GEL). Other battery types (NiCd, NiMH, Lithium-Ion and others) may also be tested using the EC1000™ and EC2000™.
-
product
Electrochemical Migration (ECM) Testing
Testing for electrochemical migration (ECM) would occur in the case of a field failure return. Metal migration between isolated conductors on a completed printed circuit assembly may produce electrical shorts.Why does this growth occur and what do you need to look for? Basically, we need to know if our assemblies are “dirty.” By dirty, we mean littered with ions. Ions on printed circuit assembly surfaces can cause short circuits. In simple terms, shorts occur when the space between the conductors is bridged by dendrites formed by re-deposited metal ions. This metal migration is best described by IPC as a reverse plating of the conductors in the presence of ions, water and an electrical potential.
-
product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
product
EIS Interface (Electrochemical Impedance Spectroscopy)
BATT470m
The BATT470m electrochemical impedance analysis interface (EIS) provides an easy to use battery/cell impedance test platform for the electrochemical industry. Utilizing the highly accurate PSM3750 frequency response analyzer from N4L, the BATT470 provides impedance measurement of batteries/cells up to 100V DC. With a frequency range of 100mHz to 1MHz, the BATT470m covers a wide range of applications. Our software package - PSMComm2, featuring “EIS” mode, displays the in-phase and quadrature impedance of the cell in Nyquist form as well as overall impedance (Z), in bode form.
-
product
Time-Resolved Electrochemical Quartz Crystal Microbalance
400C Series
The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).
-
product
Electrochemical (Molecular Electronic Transfer) Motion Sensor transducers
The Molecular Electronic Transfer Technology
The basic design of the MET transducer, shown in Figure 1. The transducer is contained in a channel, 1, of a sensor filled with a specially prepared electrolytic solution. It consists of four fine platinum mesh electrodes, two anodes, 2, and two cathodes, 3, separated by thin, microporous ceramic or polymer spacers 4. Such an assembly is held together by a housing 5. To measure the motion of the fluid, it must be converted into an electrical signal. One way of achieving this is by using the convective diffusion of the ions in the electrolyte. At the heart of a MET device are inert electrodes at which a reversible redox reaction occurs, which does not involve either plating of a metal or evolution of a gas.
-
product
Reference Electrodes
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
product
Micro-Fuel Oxygen Analyzer
InstaTrace
Teledyne Analytical Instruments
Teledyne's patent pending innovation called InstaTrace eliminates the greatest inconvenience associated with electrochemical oxygen sensors at the trace level -- the wait.When a typical electrochemical trace oxygen sensor is removed from its barrier bag for the purpose of replacing an expired sensor, it is exposed to ambient air (209,000 ppm O2).
-
product
Gas Analysis
HPR-40 DEMS
The Hiden HPR-40 DEMS is a bench top or mobile cart mounted module for analysis of dissolved species in electrochemistry. The system is modular and adaptable. The system includes two differential electrochemical mass spectrometry ‘DEMS’ cell inlets, designed for material/ catalysis studies, cell type A, and electrochemical reaction studies, cell type B.
-
product
Electrochemistry
Portable Line
Portable Line potentiostats/galvanostats combine electrochemical research in the laboratory with on-site research using well-established electrochemical techniques.These small and affordable portable instruments enable you to develop applications for your specific research needs. Portable Line instruments are an ideal solution in many research areas, such as (bio)sensor, corrosion, or (bio)fuel cell.
-
product
Trace Oxygen Analyzers
Alpha Omega Instruments trace oxygen analyzers and transmitters incorporate an advanced electrochemical sensor that provides exceptional life, accuracy, and stability. Alpha Omega Instruments electrochemical sensors provide as much as three times the life of conventional “fuel cell” type sensors. And, if you are looking to measure from parts per billion to 100%, Alpha Omega Instruments offers a high-performance zirconium oxide oxygen sensor.
-
product
Electrochemistry
Modular Line
The Modular Line of instruments consists of a range of instruments to suit any requirements in electrochemical research, from low to high voltage and from low to high current.
-
product
Flow Cell Kit
QCMT
The quartz crystal microbalance (QCM) technique under electrochemical frequency is very useful to determine many compounds such as metal proteins, metal ions and thiol-conjugated oligonucleotides.
-
product
Addon Cards
Fit the IM6/Zennium electrochemical workstation to your application. Control external potentiostats, capture additional physical properties or enhance your system to a true parallel impedance analyzer.
-
product
Radiometer Analytical Probes
Radiometer Analytical develops and manufactures an extensive range of electrochemical electrodes - combined pH, glass or reference electrodes, metal electrodes, ion-selective electrodes and conductivity cells - for every application and budget.