Filter Results By:

Products

Applications

Manufacturers

Showing results: 2716 - 2730 of 3680 items found.

  • Sample Pretreatment For Optical Emission Spectrometry

    Shimadzu Corp.

    Samples are taken from molten metal, thin sheet, semi-complete or complete products. When sampling molten metal with a ladle, small quantities of molten metal are poured into a casting mold. Unnecessary parts of the sample are removed using a grinder or a cutter. As particles from a grinder may contaminate the surface of the sample, a lathe or milling machine is used (not a grinder) to cut soft samples such as white metal. If trace elements are not being investigated, a grinder or belt sander can be used. However, to minimize contamination, the grinding wheel or belt should be changed for each sample. Samples excised from semi-complete or complete products must be at least 12 mm in diameter. Small rod-shaped samples can be analyzed using special equipment.

  • C Series CANopen Interface Module

    NI

    The C Series CANopen Interface Module is a high-speed interface for developing CANopen applications. CANopen is a higher-level communication protocol based on the controller area network (CAN) physical layer. It was designed for motion-oriented machine control networks, but now it is used in a variety of products and applications, including medical equipment, maritime electronics, building automation, and more. The C Series CANopen Interface Module can transmit and receive process data objects (PDOs) and service data objects (SDOs) according to CiA-DS 301. Using the NI-Industrial Communications for CANopen driver, you can batch edit SDOs, configure slave nodes with LSS services support, as well as perform network management (NMT), heartbeat, node guarding, and CANopen synchronization functions.

  • Medical Leakage Current Tester

    2675Y - Shenzhen Chuangxin Instruments Co., Ltd.

    The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.

  • Sulphur Dioxide Test Chambers

    ACMAS Technologies Pvt. Ltd.

    The Sulphur Dioxide Test Chambers from Weiber are Corrosion Test Chambers used for testing the corrosion resistance of metallic surfaces and outer protective layer of coatings. They are used to create a highly corrosive environment rich in corrosive gases and natural humid conditions to induce accelerated corrosion in protective coatings of machines and equipments, electrical items, electronic parts and components, mechanical constructions, automobile and aircraft parts and components etc. Since the corrosive action of Sulphur dioxide also depends on specific temperature and humidity conditions and the presence of other contaminants, the Weiber Sulphur Dioxide Test Chambers are designed to create optimal conditions of temperature and humidity and also make provisions for introducing impurities and contaminants. These equipments operate across a wide temperature range, creating variations in the working temperature to mimic a natural weathering environment.

  • Total Energy System

    5000 - The Eastern Specialty Company

    The electric vehicle (EV) charging market is rapidly expanding, with more and more people switching to electric cars. As the demand for EV charging stations increases, so does the amount of energy that is being exchanged. This energy exchange market is already massive, with charging peaks reaching into the megawatts of energy. With this amount of energy comes a significant amount of revenue, which requires the most accurate billing possible. That’s where TESCO’s Catalog No. 5000 – Total Energy System comes in. The Catalog No. 5000 is a double duo system that enables the testing and accuracy verification of Electric Vehicle Service Equipment (EVSE) and Field Test Equipment for testing EVSE’s in the field. This system is a dual-purpose DC and AC System and includes both a 100A AC (ACT-100) Test System and a 200A DC Test System (DCT-200).

  • Handheld spectrum analyzer/Signal analyzer

    MICRONIX

    Recently, a lot of equipment have taken the high frequency or microwave technology according to the advancement and the spread of the telecommunication equipment. As a result, the handheld spectrum analyzer to analyze the signal by the frequency domain is necessaries now. The handheld spectrum analyzer is roughly classified into a heterodyne method and a Fourier transform method. The heterodyne method is also called the swept frequency method and makes it possible to measure up to tens of GHz though only for the steady signal. On the other hand, the Fourier transform method is also called the real time method and can handle an unsteady signal though the low measuring frequency range up to tens of MHz. As for our spectrum analyzer or signal analyzer, the MSA300/400 series adopts the swept frequency method, and the MSA500 series adopts both the swept frequency method and the Fourier transform method.

  • Air Data Computer (ADC) Tester

    MS 1122 - Meltronics Systemtech

    The ADC tester is used in 2nd line maintenance is to check the functionality of ADC. This unit is a rugged customized hardware based on full functionality test of ADC. The Air Data Computer (ADC) Tester is a fully automated GO/NOGO tester with full functional testing in 2nd line maintenance. This tester is to test ADC at unit level and identify faulty Shop Replaceable Unit (SRU). This tester is also used to carry out PI checks on ADC before clear them for installation on aircraft. ADC Interface board designed to test full functionality of ADC. The Air Data Computer (ADC) test equipment shall be used for testing ADC of Tejas Aircraft. ADC test equipment shall verify the functionality against specifications during second line maintenance and pre-installation on the aircraft.

  • FM Tokenless Transmitter & Receiver

    MS 1522 - Meltronics Systemtech

    Transmitter and Receiver units are designed to work at 24V DC voltage (nominal) with variation between 19.2 V to 28.8V. The system is designed to work with carrier frequency 1800/2700 Hz and modulated frequency 65Hz/85Hz. For 1800Hz Carrier Frequency RED border is used in Front Panel and for 2700Hz Carrier Frequency BLUE border is used in Front Panel. Maximum power consumed by transmitter and receiver are 1.2W and 8W, respectively. Sense level for receiver is less than –19 dBm and No sense level for receiver is more than –22 dBm with 1mw (0 dBm) transmitter power. The equipment is designed to work satisfactorily with temperature variation from 0°C to 55°C with relative humidity of 95% at 35°C. Suitable test points are provided in the back of the equipment to monitor the necessary parameters.

  • Stripline Automotive 10KHz-30MHz 50 Ohm

    STPL-30 - EMCTEST

    The GTEMCELL STPL-30 Stripline is designed to produce high electric fields over a controlled bandwidth. It is used to perform EMC measurements according to automotive and aerospace standards in order totest the immunity of automotive and aircraft equipment to radiated electromagnetic fields.The STPL-30 uses a dual-sided tapered adjustable feed design into a tunable transmission line.

  • Human Exposure Measurements to Luminaries

    AFJ Instruments

    Through different ways of coupling between luminaries and humans, a level of exposure of a person to electromagnetic fields can be derived. One part of the exposure is based on capacitive coupling between lighting equipment and person. This creates induced internal electric field that must be evaluated using an EMI receiver and a Van Der Hoofden test head.

  • Carrier to Noise Generators

    CNG-DX - Hollis Electronics Company LLC

    CNG-DX provides improved noise generation with its internal digital power meter and built-in noise generator. This single instrument provides accurate and repetitive carrier-to-noise setting ability in one box. The CNG-DX is an ideal instrument for creating realistic scenarios for closed loop testing of satellites, ground equipment and mobile transceivers.

  • 635nm Visible Light Source

    VLS-40 - KD Optics Ltd.

    The KD Optics VLS-40 is an easy to use, hand-held, visible source used for testing fibre optic cable installations. It is especially useful when testing fibre optic cables close to the terminal equipment. The unit is pocket sized with a long battery life, making it ideal for local fault finding and continuity checking of fibres.

  • Meter Test System

    MTS-50 - Kongter Test & Measurement Co., Limited

    This meter test equipment features state-of-art designing with high accuracy. It is composed of high accurate (class 0.05% or 0.1%) standard reference meter and power source (up to 50A). This system is particularly designed with modular structure for calibration and test of different single phase/3 phase electronic/inductive active and reactive energy meters.

  • Flying Probe Test Programming & Testing Services

    Zero Defects International LLC

    ZDI utilizes a Seica flying probe tester in order to provide test program development and testing services to customers in Silicon Valley and throughout North America. This is a very cost-effective solution for printed circuit assembly manufacturers who do not have in-house equipment of their own but have customers who require test services.

  • Noise Control And Acoustical Consulting Services

    Potomac Instruments, Inc.

    Our acoustical consultants use the latest and most advanced noise prediction and modeling software, precision sound measurement equipment and detailed acoustical analysis that enable us to help our clients achieve their project's noise requirements and goals. Contact us before your noise challenges become noise pollution problems.