Showing results: 151 - 165 of 989 items found.
-
40-203-002 -
Pickering Interfaces Ltd.
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
40-202-101 -
Pickering Interfaces Ltd.
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
40-202-001 -
Pickering Interfaces Ltd.
This is the 22 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test.
-
40-196-101 -
Pickering Interfaces Ltd.
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
40-196-001 -
Pickering Interfaces Ltd.
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
BAUR Syscompact 4000 -
BAUR Prüf- und Messtechnik GmbH
Fault location with Syscompact 4000. The Syscompact 4000 is a compact, fully enclosed fault location system for pre-location and pinpointing of high-resistive, low-resistive and intermittent faults on low- and medium-voltage cables. Easy operation and the use of latest fault location methods enable fast and safe fault location.* Location of low-resistive, high-resistive and intermittent cable faults* Efficient cable fault pre-location methods* Pinpointing according to the noise location method or acoustic propagation time measurement* (with Universal Locator and ground microphone)* Sheath fault location according to the step voltage method (with Universal Locator and two measurement probes)* Easy to handle
-
Syscompact 2000 -
BAUR Prüf- und Messtechnik GmbH
Fault location with Syscompact 2000. The Syscompact 2000 is a multifunctional cable fault location system designed for modular 19" rack technology. The integrated surge and test generator is used for cable and sheath testing as well as for precise location of high-resistive and intermittent faults. The SYSCOMPACT 2000 is preferably used in low- and medium-voltage networks for fault location up to a cable lengths of 65 km. * Fast and reliable * Precise, dependable cable fault location High performance * high voltage unit* Integrated proven cable fault pre-location methods
-
-
Sensorform OFI-FLS -
Suparule Systems Ltd.
The Sensorform OFI-FLS is a Fault Passage Indicator for Overhead Lines, which is designed to assist in the rapidlocation and isolation of faults on Medium Voltage networks (1-38kV). When the current in the phase exceeds a preset level, the fault is indicated by means of both a mechanical flag indicator and high-intensity LED indicators.
-
RapidTrace 1100 -
Vonaq Ltd
*This TDR / Cable Fault Locator is suitable for testing all Communication CAT (3-6) , Power Cabling , coaxial and mains power cabling*The RapidTrace 1100 TDR / Cable Fault Locator has a 11 measurement ranges from 0.5m to 3500m (3.5km) and is accurate to 1%*The TDR / Cable Fault Locator has 25, 50, 75 & 100ohm Selectable Cable Impedances*Using pre determined gain and pulse width on the TDR / Cable Fault Locator, all major operating and setting parameters can be easily accessed
-
IFDIS -
Copernicus Technology Ltd
The IFDIS™ uses patented Intermittent Fault Detector technology that simultaneously and continuously monitors every circuit path within a Unit Under Test (UUT) - such as a Line Replaceable Unit (LRU) chassis' interconnects - for intermittent continuity failures that occur for as short as 50 nanoseconds. This state of the art technology is combined with an environmental chamber and vibration table, which simulate the UUT’s operational environment and cause intermittent faults to manifest, creating a system that is unsurpassed in intermittent fault detection.
-
Pickering Interfaces Ltd.
All of our fault insertion matrices feature a breakout arrangement that allows faults to be attached to the sensor lines via the Y axis. This includes the breaking of a connection or the adding of a series defect – all of which can simulate connectivity problems in the system. The three pin breakout versions allow the connection to be swapped for a “bad” sensor simulation.
-
ECFL 30 -
Elektronika
Compact precision active/passive, AC/DC bridge with dual channelTDR for fault location on balanced loaded and unloaded cables.
-
NEO TELE-TRONIX PVT. LTD
Widely used in electrical and power generation sector for testing underground cables in order to detect any fault.
-