Showing results: 361 - 375 of 1012 items found.
-
The Derwent Group
A High-Stability adjustable Load Cell Simulator. It is specifically designed for Load Cell Fault and System Fault Diagnosis. It also provides a useful Development Tool for any System which relies upon Load Cells. The Output Signal is adjustable from -0.1 to +3.1 mV/V.
-
Concurrent Real-Time
Flexible, programmable signal conditioning and fault insertion solutions for data acquisition applications.
-
-
UltraScan -
Syntest Technologies
UltraScan is SynTest's solution to combat increase in test time. In 130 nm or smaller ? nanometer geometries, many defects become delay defects and it becomes necessary to use delay tests to detect the transition faults and path delay faults. Often bridging tests are also required.
-
Schweitzer Engineering Laboratories, Inc.
Recloser controls provide fault location, isolation, and system restoration using protection and communications capabilities, such as Automatic Network Reconfiguration and single- and three-phase tripping. They allow you to automatically reconfigure your distribution system to isolate faults, quickly restore service, and reduce customer impact.
-
UL 30 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR UL 30. The UL 30 receiver is used together with a ground microphone (BM 30) and a surge voltage generator (SSG, STG) to pinpoint cable faults. With the coil integrated in the BM 30 for runtime measurement, the device determines the time difference between the magnetic and acoustic signal. This particularly offers special advantages when d ealing with faults difficult to locate acoustically.* Built-in speaker* Splashproof design* Large, illuminated display* Lightweight
-
Technology Products
Technology Products offers a complete range of Cable Fault Locating Equipment for LV & HV Cables in Power Plants, Heavy Industry & Distribution Systems . Occurrence of cable fault can not be avoided due to many factors. Long outage of a cable from service results in heavy loss of revenue to the power distribution company, production loss to industries as well as unpleasant condition to general public. This requires an efficient instrument capable of locating the fault in minimum possible time and restoring the supply.
-
MI 2014 -
Metrel d.d.
Cable Scanner is easy to use LAN tester with wide variety of functions for fault finding and troubleshooting on IT cabling connections. TDR facility with adjustable NVP allows determination of distance to the fault or cable length measurement. Acoustic generator combined with a receiver enables pair determination in multi-pair cables.
-
YAV90089 -
6TL Engineering
48 channels 2A 250V 2 Fault Insertion Buses Switching up to 60W
-
AudioJog Pro 3 -
CableJoG Ltd
Audio cable tester with SINGLE & DOUBLE ended testing, memory and intermittent fault detection .
-
AFI-400 -
Shanghai Fibretool Technology Co.,Ltd.
AFI-400 Optical Fiber Identifier is an important tool for optical maintenance, which is used for nondestructive fiber identification work, can be detect in any location of both SM and MM fiber. Meanwhile it also has Visual Fault Locator module with fault location function. It is the ideal instrument for online test.
-
IRG 2000 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR IRG 2000. The IRG 2000 impulse reflection measurement unit or time domain reflectometer is a handy, easy to carry device for single-phase cable fault pre-location. It is used in combination with a surge voltage generator on low-, medium- and high-voltage cables 0 - 65 km in length. It can also be used on live cables carrying voltage up to 400 V.* Easy and quick cable fault location* Light, compact and manageable* Main unit for the tried-and-tested pre-location method* Ideal for integration in measurement systems
-
Signals & Systems India Private Limited
The Display used to monitor the 20Hz and 50Hz current passing through NGT transformer. This could help to monitor the stator earth fault and could record the current every minute. The current shall be displayed in milliamps for both 20Hz and 50Hz. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. The current can be measured using clamp-on CT which would be clamped between load resistor and NGT. It gives an indication of the current values are lower or higher than the set threshold.
-
ETDR 10A-3 -
Elektronika
Compact single channel precision portable easy to useTDR for fault location on balanced unloaded cables.
-
DIGAMEL Subestaciones
In this category you will find the necessary equipment to maintain, test and detect faults in backup battery banks.