Showing results: 436 - 450 of 989 items found.
-
A078DMR-078DFR-9A050 -
Pickering Interfaces Ltd.
The A078DMR-078DFR-9A050 is a 78-Pin Male to Female D-Type Cable Assembly with twisted signal pairs suitable for differentialsignals and is designed to be used with Pickering's 40-200 fault insertion switch.
-
A078DMR-078DFR-9A100 -
Pickering Interfaces Ltd.
The A078DMR-078DFR-9A100 is a 78-Pin Male to Female D-Type Cable Assembly with twisted signal pairs suitable for differentialsignals and is designed to be used with Pickering's 40-200 fault insertion switch.
-
Yamaichi Electronics Co., Ltd.
A test socket is the ideal point to test your home’s internal phone wiring for faults. You can also use it to identify any potential faults with the phone line outside. Your test socket is located in your master socket. It is the point between the internal phone wiring in your house and the phone line outside. That means by plugging into your test socket you can bypass all the internal wiring and test your device directly on the phone line.
-
TG 600 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR TG 600. The TG 600 audio frequency transmitter was designed specifically for the precise location of cable faults and joints using the twist method. The display of the input and output current makes selection of the correct adjustment easier.* High-performance audio frequency transmitter up to 600 VA* Frequency of 2 or 10 kHz, quartz-stabilised (other frequencies on request)* Potential-free output* Impedance adjustment in 8 steps from 0.3 to 300 Ω
-
ADACS -
Leonardo DRS, Inc.
This high-speed damage-control system was built around Arc Fault Detect and Continuous Thermal Monitoring (AFD/CTM) from the Johns Hopkins Applied Physics Laboratory. When AFD/CTM detects dangerous arc faults — powerful discharges of electricity between conductors — the ADACS system immediately cuts power to the affected circuit before it can damage equipment or injure nearby personnel. Altogether, the system prevents loss of life, preserves countless repair dollars and assures continuous readiness.
-
Loran C Accufix 7500 -
BCO, Inc.
USCG Loran Transmitter Control and Display stations modernized and upgraded to state-of-the-art processor controlled technology. Fully redundant system with comprehensive built-in performance monitoring. Automatic switchover upon detection of error, high single point failure tolerance. Long distance communications link supports remote station operation on a continuous basis. Built-in fault detection and monitoring enables dynamic re-allocation of failed subsystem modules, and fault isolation to major replacement assemblies.
-
MaxLinear
PowerArchitect™ design and configuration software speeds development and significantly reduces overall time-to-market compared to legacy analog power solutions. An I²C interface and multiple GPIO pins ensure easy system integration. Configurable warning and fault levels, fault behavior and power up and down sequencing ensure any load can be properly powered and protected. The power system design can be completed with confidence long before the final revision of the SoC or ASIC is available.
-
778967-01 -
NI
64-Channel, ±30 VDC, Sink/Source Inputs, Bank-Isolated PXI Digital I/O Module—The PXI‑6511 is an industrial digital input interface, with eight banks of isolated channels. If a computer or application fault occurs, the PXI‑6511 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
779443-01 -
NI
The PCI-6520 is an industrial digital I/O module with high channel isolation and industry-standard 24 V logic levels. For added safety the PCI-6520 requires a keyed connector. If a computer or application fault occurs, the PCI-6520 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. It also features programmable power-up states, digital filtering, and change detection for optimal control over your application.
-
784539-01 -
NI
The NI-9775 provides referenced single-ended analog inputs with two timing modes for applications such as fault detection in electrical transmission lines or structural failure events. You can use the NI-9775 to measure finite samples up to 20 MS/s/ch to capture fault detections or to measure continuously at up to 4 MS/s. You also can use the built-in analog reference trigger to assist with high speed phenomena. Additionally, the NI-9775 supports waveform streaming at a lower sample rate.
-
Bearing Defender -
ACOEM
The patented, wireless Bearing Defender provides instantaneous feedback on bearing health. It is user-friendly, can be used on just about any industrial machine, and detects bearing faults quickly and accurately.
-
Iris Power LP
Current signature analysis motoring detects rotor cage winding faults in induction motors including broken rotor bars, cracked shorting rings and unequal air gaps.
-
MODBSDL -
ACUGEN Software, Inc.
MODBSDL Software reads a BSDL file and writes an ACUGEN-format simulation model. This model can then be simulated and fault graded using ACUGEN's ATGEN product, or converted to another simulation format.
-
SIT-12 -
DeltaTech Electronics
The SIT-12 Tester is a portable device for measuring electrical parameters of (unit) injectors. Thanks to the unique combination of all the electrical measurements into one device it is possible to quickly diagnose faults.
-
Schweitzer Engineering Laboratories, Inc.
Transformer protection products and systems provide complete primary and backup protection for all types of transformer faults. They are suited for use in utility-, industrial-, and commercial-scale power transformer systems.