Showing results: 676 - 690 of 989 items found.
-
FFA-2 -
Langeo Co., Ltd.
FFA-2 quick α digital scintillation actinography is designed to measure α ray intensity in soil sample or on α cards for the purpose of locating geological structure, such as concealed fault, fissure, fracture zone, underground water reservoir, and the tectonic cloud of the natural gas and oil. It can also be used to engineering geology exploration, the deep uranium mineral ore, regional radon detection (environmental protection detection), and trace original gold vein.
-
40-480-221 -
Pickering Interfaces Ltd.
The 40-480 is designed to simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. It allows automotive I/O devices to be tested for correct operation under adverse conditions. The design includes protection circuits that ensure module damage cannot be caused by wiring faults or UUT failures. Each module can support up to 32 channels and is suitable for both 12V and 24V automotive applications.
-
Reltech Limited
HALT is a process used on electronic assemblies and modules to determine weaknesses and the stress limits of a product by temperature cycling and omni-axial random vibration step stress. Inherent weaknesses in a products design and build are stimulated by applying increasing levels of mechanical stress. Within an accelerated timescale, faults in a product can be realised prior to product release and preventing failures occurring during after-sale user operation, very often during the warranty period.
-
40-480-121 -
Pickering Interfaces Ltd.
The 40-480 is designed to simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. It allows automotive I/O devices to be tested for correct operation under adverse conditions. The design includes protection circuits that ensure module damage cannot be caused by wiring faults or UUT failures. Each module can support up to 32 channels and is suitable for both 12V and 24V automotive applications.
-
Bender Inc.
Ground-fault products are used to monitor grounded systems (ungrounded and grounded) for fault currents or residual currents. The sum of all conductors except the protective earth conductor is measured by means of measuring current transformers.In general, ground-fault monitors (RCM - residual current monitors) are used to send a message to the user even before reaching the shutdown threshold of the GFCI. Ground-fault monitors detect deteriorations of the insulation level at an early stage and in a reliable way.
-
DCZCT-20M -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement for solar power system*Least affection from the magnetization of core and temperature fluctuation*DC leakage current measurements*Current measurements for small DC motor*Convenient +5V single polarity power supply
-
Platinum Tools
Offers a complete solution to test and speed certify the data-carrying capabilities of Ethernet network cables up to 1 Gb/s by testing for noise in the network, detecting faults in the cable wiring, and ensuring that cables are able to support the speed capabilities of active equipment.
-
HL1100 Series -
Hyperlabs, Inc.
HYPERLABS HL1100 Series TDR instruments provide high-performance test and measurement capabilities for use in the field or in the lab. These instruments are used for applications such as fault detection in cables and interconnects, impedance characterization, time of flight analysis, water level measurement, and more.
-
778572-14 -
NI
7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
778572-12 -
NI
7-Channel, 10 A PXI Signal Insertion Switch Module—The PXI‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
779084-01 -
NI
The PCI-6518 is an industrial digital I/O interface, with two banks optically isolated channels. The device is ideal for industrial control and manufacturing test applications. The PCI-6518 module is an industrial digital I/O interface, with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6518 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.
-
779085-01 -
NI
The PCI-6519 is an industrial digital I/O interface, with two banks optically isolated channels. The device is ideal for industrial control and manufacturing test applications. The PCI-6519 module is an industrial digital I/O interface, with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6519 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.
-
779976-01 -
NI
The PCIe-6509 can directly drive external digital devices such as solid-state relays (SSRs). You can configure each port for input or output, and no external power supply is required for outputs. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. If a computer or application fault occurs, the PCIe-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
778965-01 -
NI
64-Channel, ±30 VDC, 32 Sink/Source Inputs, 32 Source Outputs, Bank-Isolated PXI Digital I/O Module—The PXI‑6514 is an industrial digital I/O interface with eight banks of isolated channels. With programmable power-up states, you can configure the initial output states in software to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PXI‑6514 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
MGS-402 -
Bacharach, Inc.
Bacharach’s MGS-402 Gas Detection Controller centralizes the status of up to two gas detectors, provides a complete package for your safety compliance application. On the front panel of the MGS-402 a bank of LEDs corresponds to each connected gas detector; showing power, alarm status and fault indicators. The MGS-402 can provide the power requirements for to up to two gas detectors, which can be daisy-chained with Modbus communication to each gas detector; simplifying and reducing the cost of installation.