Filter Results By:

Products

Applications

Manufacturers

Showing results: 856 - 870 of 989 items found.

  • Cable & Antenna Analyzer

    CAA-100 - ShinewayTech

    ShinewayTech® CAA-100 cable & antenna analyzer can test Return Loss and VSWR of load’ frequency. Also can get Return Loss, VSWR of DTF (distance-to-fault) and Cable Loss. Users can be easy to know the connection of cable & antenna system is reliable whether or not. CAA-100 series with frequency range 25MHz-4GHz and 60dB dynamic range can suitable for 2G/3G/4G/WiMAX system etc. CAA-100 series is the necessary measuring instrument for the new generation of wireless network development, upgrade and maintenance.

  • Portable OTDR Tester

    CARY-OT4000 - UC Instruments, Corp.

    The CA OPTRONICS CARY-OT4000 series portable optical time domain reflectometry (OTDR) is the latest FTTx optical fiber cable-based test instrument. It has light weight, elegant appearance, small size, easiness of installation and maintenance, high-capacity built-in battery. It provides multiple built-in test wavelengths and optical testing functions like visual fault locator (VFL). As a new product specially designed for FFTx network testing, it provides site technicians with the highest performance and upgrade services.

  • Maintenance & Test Equipment

    Mors Smitt Group

    The D-dock system consists of a D-dock Test Block which is put between the existing relay socket and the existing D-U plug-in relay. All 14 relay-pins are wired to the Break-Out Box enabling to connect measuring equipment like multimeters, scope meters or data analyzers to log operations during longer period. This makes fault finding easy. The D-dock fits in tightly packed relay panels and small cabinets. It can operate unattended enabling normal passenger operating service.

  • Partial Discharge Inductor

    Tracy - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR tracy. The BAUR tracy partial discharge inductor induces a signal at the apparent fault location in the cable from outside. In combination with any PD measurement system, e.g., PHG TD/PD, the induced signal can be located and compared with the result of the partial discharge pre-location. The partial discharge location can thus be determined precisely.* Portable, battery-operated signal coupling device* Suitable for cables and cable accessories* Inductive signal coupling* Aviods costly, unnecessary replacements of PD-free cable accessories

  • Audio Frequency System

    Locator Set / UL 30 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR Locator Set / UL 30. The audio frequency system Locator Set is used to exactly determine the alignment of cables and metal gas or water pipes. With various accessories, this system becomes a universal, indispensable device for power companies, industries, installation companies and water suppliers.* Output energy up to 50 VA* Automatic or manual impedance adjustment* Charging unit and rechargeable battery integrated; battery or mains operation* Continuous or cyclical output

  • Solder Joint Inspection – AOI

    S3088 ultra - Viscom AG

    *Extremely fast AOI camera system.*Scalable, modular camera technology with 3D measuring function.*Greatest inspection depth: reliable inspection of 03015 und fine-pitch components.*Maximum fault coverage - 9 views plus 3D measurement.*Best resolution at angled views.*Height measurement of components.*Extremely high throughput due to FastFlow Handling.*Revolutionary simplicity in AOI operation with vVision.*Fast program generation with vVision/EasyPro.*Reading DataMatrix code, bottom up.

  • Multi-Function Recorder

    Platinum 2.5K - Ametek Power Instruments

    For all types of power system events, the Platinum 2.5K Multi-Function Recorder provides all the information you need to capture the complete picture. This comprehensive fault recorder simultaneously performs transient, sequence of events and disturbance recordings, phasor measurements and power quality analysis. All of these functions are performed at the highest level so it will meet your needs of today and the future. In a deregulated environment, the Platinum 2.5K is the best tool to provide the necessary data to increase revenues and retain your customer.

  • Vibration Table Top system

    OVTT 18 - Qualmark Corporation

    The OVTT, Omni-Axial Vibration Table Top system, is the first, stand-alone, compact, repetitive-shock vibration system on the market. The OVTT 18 system is ideal for No Fault Found (NFF) precipitation screens of field returns, repair verification and random vibration test of small products. The OVTT 18 utilizes Qualmark's patented six-degree-of-freedom vibration technology and is designed with reduced air requirements and low noice levels. The OVTT 18 system can be easily configured for placement inside a thermal chamber for combined stress tests.

  • Communications System Analyzer

    Freedom R8200 - Astronics Corporation

    The Freedom R8200 from Astronics Test Systems represents a major step in the evolution of the Land Mobile Radio Test. The Freedom R8200 is the first and only test instrument that combines comprehensive digital and analog LMR testing with the ability to measure important RF network characteristics, such as Distance to Fault (DTF), Return Loss, and Voltage Standing Wave Ratio (VSWR). The Freedom R8200 is also the only service monitor with the abilityto display advanced RF Parameters in a Smith Chart for more complicated network analysis

  • GPS/GNSS Antenna Signal Splitter 2-Way, TNC Female, IP67 Weatherproof, 1-2 GHz

    GPS221 - INSTOCK Wireless Components, Inc

    GPS221 is a two way, passive, GPS signal splitter ideal for splitting a GPS antenna signal between two receivers while providing a DC current path to power a remotely located active GPS antenna from one receiver while blocking the DC path from the other. Furnished with TNC female connectors all ports. A special feature of this unit is the 200 ohm internal load which provides a current drain for the GPS receiver not powering the active antenna. Some GPS receivers incorrectly sense an antenna fault when there is no current draw. The 200 ohm internal load provides a simulated antenna current drain which prevents receiver faulting. Max voltage rating at the DC blocked port is 15 VDC; maximum current rating is 75 mA. Max voltage rating at the DC pass port is 50 VDC; max current rating is 2000 mA.

  • GPS/GNSS Antenna Signal Splitter 3-Way, TNC Female, IP67 Weatherproof, 1-2 GHz

    GPS321 - INSTOCK Wireless Components, Inc

    GPS321 is a three way, passive, GPS signal splitter ideal for splitting a GPS antenna signal between two receivers while providing a DC current path to power a remotely located active GPS antenna from one receiver while blocking the DC path from the other. Furnished with TNC female connectors all ports. A special feature of this unit is the 200 ohm internal load which provides a current drain for the GPS receiver not powering the active antenna. Some GPS receivers incorrectly sense an antenna fault when there is no current draw. The 200 ohm internal load provides a simulated antenna current drain which prevents receiver faulting. Max voltage rating at the DC blocked ports is 15 VDC; maximum current rating is 75 mA. Max voltage rating at the DC pass port is 50 VDC; max current rating is 2000 mA.

  • GPS/GNSS Antenna Signal Splitter 4-Way, TNC Female, IP67 Weatherproof, 1-2 GHz

    GPS421 - INSTOCK Wireless Components, Inc

    GPS421 is a four way, passive, GPS signal splitter ideal for splitting a GPS antenna signal between two receivers while providing a DC current path to power a remotely located active GPS antenna from one receiver while blocking the DC path from the other. Furnished with TNC female connectors all ports. A special feature of this unit is the 200 ohm internal load which provides a current drain for the GPS receiver not powering the active antenna. Some GPS receivers incorrectly sense an antenna fault when there is no current draw. The 200 ohm internal load provides a simulated antenna current drain which prevents receiver faulting. Max voltage rating at the DC blocked ports is 15 VDC; maximum current rating is 75 mA. Max voltage rating at the DC pass port is 50 VDC; max current rating is 2000 mA.

  • Battery Portable Passive Intermodulation Analyzer

    iPA Series - Kaelus

    The iPA Series Passive Intermodulation (PIM) analyzer is the first battery powered PIM Test Analyzer versatile enough to support multiple test scenarios such as testing at the top of the tower, base of tower, roof top and in-building for DAS systems. This IEC compliant 20W, rugged, battery operated design includes a tablet computer in a ruggedized case for remote control. This allows hands-free dynamic testing that is safe and convenient. Add the optional Range to Fault (RTF) module to quickly identify the location of PIM and Return Loss sources.

  • GAOTek Handheld Gigabit Ethernet Tester

    A0060001tek - GAO Tek Inc.

    GAOTek Handheld Gigabit Ethernet tester is designed for installation and maintenance of 10 M/100 M/1000 M Ethernet networks. It combines the functions of network testing, data packet capture, traffic generation, cable testing and BER testing into one unit. It also integrates full RFC-2544 and Y.1564 tests. Featuring an ergonomic design and 5.0 inch LCD color touch screen, this Ethernet tester helps the front-line field workers to analyze the network quality and locate faults rapidly. Test results can be shown graphically and numerically.

  • VDSL Tester

    X5008 - Shinho Company

    X-5008 VDSL tester specially designed for slid line test (xDSL include: ADSL, ADSL2, ADSL2+, READSL, VDSL2 etc) and maintenance It provides xDSL test, PPPoE dial test, DMM test, Modem emulation, line voltage indication and so on. X-5008 VDSL Tester also introduces the Optical Power Meter and Visual Fault Locator function into the unit, as well as the TDR function. It is one mufti-function tester with smart size, true color LCD and powerful management software as well as the 6600mAh rechargeable battery etc.

Get Help