Determine the location of faults.
- Pickering Interfaces Ltd.
product
PXI Single Bus 64-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-401
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Fault Location
REFLEKT
REFLEKT makes fault location more efficient, effective and practicable than ever before, even on complex networks.
-
product
Cable Fault Location
BAUR Prüf- und Messtechnik GmbH
BAUR cable fault location devices and systems cover the entire cable fault location process: During pre-location, the position of the fault is roughly located. The subsequent pinpointing enables precise determination of the cable fault. You can use various measurement methods depending on the kind of fault and cable type.
-
product
Overhead Fault Location
Schweitzer Engineering Laboratories, Inc.
Overhead faulted circuit indicators include easy-to-spot displays to help direct line crews to the faulted line sections—enabling faster restoration of power and improved customer uptime.
-
product
Underground Fault Location
Schweitzer Engineering Laboratories, Inc.
Underground faulted circuit indicators identify the faulted cable section without a time-consuming re-fuse and sectionalize process. Applications include subsurface or pad-mounted transformers, switchgear, sectionalizing cabinets, junction boxes, and splices.
-
product
Ground Fault Location
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
product
Cable Fault Location System
BAUR Syscompact 2000 Portable
BAUR Prüf- und Messtechnik GmbH
Cable fault location system Syscompact 2000 portable. The cable fault location system Syscompact 2000 portable is used for precise location of high-resistance and intermittent faults in low and medium voltage cables.* Fast and reliable* Precise, dependable cable fault location* High performance high voltage unit* Integrated proven cable fault pre-location methods
-
product
Cable Fault Location System
Syscompact 2000 M Pro
BAUR Prüf- und Messtechnik GmbH
Cable fault location system 2000 M pro. The portable BAUR Syscompact 2000 M pro cable fault location system is used for cable fault location and cable testing in low- and medium-voltage cables up to 65 km length.* Fully integrated proven cable fault pre-location methods* Surge mode for acoustic pin-pointing* Easily transportable* Ideal for locations that are difficult to access
-
product
Cable Fault Location Equipment
Cable fault location by electromagnetic and acoustic methods (with high-voltage pulse transmitter, which is not included into the set)Detection of insulation deterioration on cables by contact and non-contact methods
-
product
Cable Sheath Fault Location
Locating cable sheath faults is one of the last steps in cable testing, occurring after you have identified the existence of a cable fault via the identification procedure based on your specific site variables and the type of system you are working on
-
product
Thumpers and Cable Fault Location
Cable testing can be broken down to different steps of the process, starting with a time domain reflectometer test to look for an incident signal on the line or, in some high resistance situations, VLF testing. These tests will identify a fault, allowing you to move on to pre-locating it. In some low resistance faults this will occur alongside the identification via the TDR.
-
product
Mobile Cable Fault Location System
BAUR Syscompact 4000
BAUR Prüf- und Messtechnik GmbH
Fault location with Syscompact 4000. The Syscompact 4000 is a compact, fully enclosed fault location system for pre-location and pinpointing of high-resistive, low-resistive and intermittent faults on low- and medium-voltage cables. Easy operation and the use of latest fault location methods enable fast and safe fault location.* Location of low-resistive, high-resistive and intermittent cable faults* Efficient cable fault pre-location methods* Pinpointing according to the noise location method or acoustic propagation time measurement* (with Universal Locator and ground microphone)* Sheath fault location according to the step voltage method (with Universal Locator and two measurement probes)* Easy to handle
-
product
Mobile Cable Fault Location System
Syscompact 2000
BAUR Prüf- und Messtechnik GmbH
Fault location with Syscompact 2000. The Syscompact 2000 is a multifunctional cable fault location system designed for modular 19" rack technology. The integrated surge and test generator is used for cable and sheath testing as well as for precise location of high-resistive and intermittent faults. The SYSCOMPACT 2000 is preferably used in low- and medium-voltage networks for fault location up to a cable lengths of 65 km. * Fast and reliable * Precise, dependable cable fault location High performance * high voltage unit* Integrated proven cable fault pre-location methods
-
product
Split-type Cable Fault Location System
Weshine Electric Manufacturing Co., Ltd
Electricity networks have had to become more flexible, reacting more quickly to the changes and needs of higher performance. This demand for flexibility is especially true where multiple generation sources occur, such as the intermittent power from renewables like solar and wind energy. While modern SMART grid technology can quickly identify faults in sub-station and generating units, cable faults can still occur anywhere on the network.
-
product
Travelling Wave Fault Location Test Kit
PH Series
PH series travelling waveform fault locating relay/equipment test set is a new device to meet the needs of testing and verification for travelling wave fault location equipment and protection relay with TWFL function.
-
product
Cable Sheath Testing and Fault Location System
Shirla
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR shirla. Shirla the fault location system is used for cable and cable sheath testing as well as for pre-location and pinpointing of cable faults. The pre-location based on the measuring bridge principle according to Murray and Glaser that is designed especially for power cables, also enables pre-location for control and lighting cables. Null balance and evaluation take place automatically.* Cable and cable sheath testing up to 10 kVC* Resistance measurement* Cable and cable sheath fault pre-location with precision measuring bridge* Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation
-
product
Vehicle Mount Cable Fault Location System
Weshine Electric Manufacturing Co., Ltd
VS2088Plus Built in Booster And Capacitor In Vehicle Underground Cable Fault Test Device
-
product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-402
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
product
PXI Dual Bus 74-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-302
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
product
Single Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-201
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
Single Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-001
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
Single Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-101
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
Dual Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-102
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.