Showing results: 196 - 210 of 4145 items found.
-
VME635091-SyncClock -
Brandywine Communications
Brandywine Communications’ VME635091-SYNCCLOCK is a time and frequency processor module that provides precision time and frequency reference to the host computer and peripheral data acquisition systems. Time is acquired from time code signals, typically IRIG B. Time is displayed on the front panel (hours, minutes, seconds) via LED digits.
-
-
NMTU/F -
Metra Blansko a.s.
The NMTU/F device is an AC voltage and frequency transducer with two independent analogous outputs. The A output measures AC voltage, the B output measures the frequency of input voltage. That´s why one single NMTU/F transducer is able to replace two customary transducers, thus making it possible to achieve significant savings in installation space.
-
Precise Time and Frequency, Inc.
The ptf 4210A Rubidium Frequency Standard is a unique solution for providing a highly stable, low phase noise, frequency reference for applications requiring atomic reference stability performance.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
FC1000 Series -
ACECO Electronics Corp.
A superb value low cost frequency counter Frequency range: 10 MHz - 3 GHz Weight: 210g Case: 80 mm * 68 mm * 31 mm stamped aluminum with black anodized finish Battery: Internal 4 * AA 600 mAH NiCd pack 8 digit liquid Crystal Display with 100 Hz resolution Low power consumption (Average 6 hour battery life)
-
TFC2.5G -
Huber Signal Processing
The device provides a frequency range of up to 5 GHz and a high spectral purity, a continuous frequency or amplitude sweep, a vector modulator with 80 MHz modulation bandwidth, a fast settling time and a high signal-harmonic ratio. Due to its modular construction, options are available for retrofit. Integrated modulation modes are AM, FM, Pulse and I/Q. An integrated baseband signal generator (for e.g. QAM) is available as option. With this, baseband signals can be uploaded into the devices' memory and converted.
-
JT 2149/DAF -
JTAG Technologies Inc.
The JT 2149/DAF is a compact, mixed-signal (Digital/Analog/Frequency) measurement module for use in JTAG Technologies’ widely-used JT 2147 (QuadPod) signal conditioning interface. The DAF module has been designed to replace a regular TAP Pod and provides 28 measurement channels plus a clock generator. When connected to a circuit board via edge connector or test fixture/jig test pins, the module enhances standard digital boundary-scan tests by enabling a series of analog and frequency measurements to be made.
-
UHF-120 -
Polytec GmbH
Polytec?s New UHF-120 Vibrometer Laser-Doppler Vibrometers (LDV) can characterize the out-of-plane vibrations at ultra-high frequencies. Polytec?s UHF-120 extends the vibration frequency bandwidthup to 600 MHz.
-
CS2-F -
Chuan Sheng Electronics Co., Ltd.
CS2-F Freqeuncy Meter is designed high accuracy measurement, display, control and communication (Modbus RTU mode) of pulse(Frequency) or AC Frequency.● The innovation feature is auto-range input from 0.01Hz~ 100KHz(~140KHz in option). The display resolution will be auto-changed to show the highest according to input frequency. They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of testing and machinery control applications. Please refer to the detail description on pages 2/33~7/33.There are not only controllers, but also an I/O interface in any system. ADtek built in difference ideal for External Control input and Relay output as like as I/O module of PLC. It’s very connivance to achieve remote monitoring and control by CS2 series.
-
F125 -
Atelier Robin Inc.
The F125 square wave frequency generator replaces our F150/155/105 frequency generators. It is a completely new design with many new features. The main one being that it can run standalone up to 1500 program files copied from a PC or Mac. It is also possible to connect the F125 to a computer via a USB port and control it with the F100 3.0 software for MS-Windows in the same way our F150/155/105 operate from a PC. Program files written for our current F150/155/105 are compatible with the new F125.
-
CH1-1006 -
VREMYA-CH JS Company
The hydrogen frequency and time standard Ch1-1006 is designed to generate highly stable, high-frequency, spectrally pure sinusoidal 5, 10, 100 MHz and pulsed 1 Hz signals and for the behavior of time-frequency measurements.
-
DFCU -
Astronics Corporation
The Dual Frequency Converter Unit (DFCU) is a revolutionary departure from traditional converters. With its ability to produce either 115 or 230 volts AC, the DFCU can support passenger and utility power anywhere in the world an aircraft operates.
-
RFCT -
Textron Systems
Textron Systems’ Radio Frequency Cable Tester (RFCT) allows for on-site testing and maintenance for radio frequency (RF) transmission paths within a platform. Using preconfigured databases of sweep parameters and pass/fail criteria, the RFCT quickly determines the status of installed RF cables. The RFCT checks each cable’s performance characteristics to include voltage standing wave ratio (VSWR), insertion loss (IL), phase and phase matching. If a cable fails a test, the RFCT automatically determines the distance-to-fault (DTF). With its intuitive touchscreen-based user interface and lightweight, ruggedized packaging, the RFCT is the gold standard for operational-level RF cable testing.
-
HFIT 8.0 -
MEDTEQ
The MEDTEQ HFIT 8.0 is intended for high frequency insulation testing against IEC 60601-2-2. This version includes in-built metering and automatic functions to make testing easy not only for design and laboratory testing, but also suitable for regular production testing.
-
FRANEO 800 -
OMICRON electronics
FRANEO 800 was developed for testing the mechanical and electrical integrity of power transformers after transportation or exposure to high fault currents. It uses the sweep frequency response analysis (SFRA) principle and measures the electrical transfer function over a wide range of frequencies.