Showing results: 1036 - 1050 of 4156 items found.
-
RESON TC4013 -
Teledyne Marine RESON B.V.
The TC4013 offers a usable frequency range of 1Hz to 170kHz and a high sensitivity relative to its size. It further-more provides uniform omnidirectional sensitivities in both horizontal and vertical planes up to high frequencies.The TC4013 is an excellent transducer for making absolute sound measurements and calibrations within a broad frequency range. It can also be applied as an omnidirectional reference projector.The overall characteristics makes TC4013 extremely applicable for laboratory as well as industrial uses.
-
Model 1072 -
Aplab Limited
Aplab Psophometer is a portable unit designed for the use of testing telecommunication equipment. It has Psophometric filter, which has the frequency response of the weighing network based on the CCITT recommendations and frequency response characteristics for unweighted measurements. The additional features included in this model are, ‘Recorder out’ available at the rear panel for plotting a response curve, built-in stable calibration signal for calibration check and Lo Battery facility to check the Battery condition.
-
DH-QL -
Teledyne LeCroy
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
DH-QL-3SI -
Teledyne LeCroy
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
DH-CSPHY-PCIE5-CEMX16 -
Teledyne LeCroy
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
DH-HITEMP -
Teledyne LeCroy
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
DH-SI-HS -
Teledyne LeCroy
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
DH-SI -
Teledyne LeCroy
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
DH-PT -
Teledyne LeCroy
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Virginia Panel Corporation
VPC's 50 GHz micro coax contacts demonstrate outstanding RF performance from DC to 50 GHz. They offer the best density for higher frequency requirements, and can be used in micro coax modules for 90 Series systems and iSeries solutions. They are available in patchcords using Flex 405 high frequency wire. For questions regarding VPC 50 GHz solutions, just click here to contact a Field Application Engineer.
-
PE42525 & PE426525 -
pSemi Corp.
These two switches set a new standard for RF SOI at microwave frequencies and significantly extend Peregrine’s high frequency portfolio into frequencies previously dominated by gallium-arsenide (GaAs) technology. Both 60 GHz switches deliver exceptional performance in all key RF parameters and have a fast switching speed of only 8 nanoseconds. The PE42525 is ideal for test-and-measurement equipment, microwave-backhaul solutions and higher frequency switching in 5G systems.
-
8473D -
Keysight Technologies
The Keysight 8473D is a high-performance detector using a gallium arsenide, planar-doped barrier detecting element. It features extremely flat frequency response over its entire band of operation and very good frequency response stability versus temperature. The Keysight 8473D is also very rugged with high resistance to ESD damage. An optimum square-law load and positive polarity output are available as special options (consult your local Keysight representative).
-
1GC1-8038 -
Keysight Technologies
The 1GG1-8038 is a passive diode frequency doubler. It is specified to operate with a 2050 GHz output frequency. Conversion efficiency is usually around -12 dB. The device has low 1/2 and 3/2 spurious output, typically 15 dBc or better. The doubler can be biased through onchip resistors to allow operation at low input levels. Up to 22 dBm at the input can be accommodated. Onchip DC blocking capacitors are included at the input and output.
-
PCTEL, Inc
Our internal and external cellular antennas cover 2G, 3G, 4G ,5G, LTE, CBRS and 5G NR frequency ranges for fixed and mobile applications.
-
AFJ Instruments
AFJ manufactures a complete range of RF emission test equipment for EMC applications.Our FFT EMI Receivers cover the frequency range from 9kHz to 3GHz.