Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
product
Embedded Local Oscillator Capability
S93084B
The S93084B tunes the network analyzer’s receivers to the output frequency of the converter under test without having to access internal LOs or a common reference signals. For converters with embedded LOs, this enables measurements of match-corrected conversion loss/gain and absolute group delay (requires S93082B and S93083B), gain compression versus frequency (requires S93086B), intermodulation distortion (requires S93087B), and noise figure (requires S93029B).
-
product
Time Domain Analysis
S93010B
The S93010B time domain capability allows you to measure the time domain response of a device. The analyzer can transform frequency domain data to time domain or time domain data to the frequency domain and runs on PNA/PNA-L/PNA-X Series B models.
-
product
110 GHz Frequency Extender
N5293AX51
The N5293AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Vector And Scalar Mixer/Converter Measurements
S93083B
The S93083B provides both fully calibrated vector and scalar measurements of mixers and frequency converters, with intuitive, easy-to-use user interface
-
product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
Millimeter-wave Operation With Frequency Extenders For M980xA PXI VNA
S95560B
banded vector network analyzer (VNA) using the M980xA PXI VNAs and N5252AW or N5262BW Frequency Extenders.
-
product
Flexible Cable, 2.4 Mm To 3.5 Mm
85134H
The Keysight 85134H is a 62.9 cm (24.75 in) long1 flexible cable with a 2.4 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.31 * sqrt (f) + 0.2 (where f is frequency is GHz) for the test port connector and 1.8 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 2.5 inch radius. Stability1 of the Keysight 85134H is less than 0.12 dB and phase is less than 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
Embedded LO Capability
S97084B
The S97084B tunes the analyzer’s receivers to the output frequency of the converter under test without the need for access to internal LOs or a common reference signal
-
product
110 GHz Frequency Extender, Pulsed DC Bias
N5293AX52
The Keysight N5293AX52 is a broadband frequency extension module designed for use with Keysight’s new PNA / PNA-X-based millimeter-wave solutions. It is a compact, lightweight, and ruggedize frequency extender module with built-in bias tee for pulsed DC bias operation. It interfaces with the Keysight N5292A test set controller. The modules allow users to extend the frequency coverage of a base PNA / PNA-X Series network analyzers to a range of 10 MHz to 110 GHz. For more information about cable and accessories for use with network analyzers, please visit Network Analyzer Accessories.
-
product
Noise Figure Measurements With Vector Correction
S93029B
The S93029B noise figure application enables high-accuracy noise figure and noise-power measurements of amplifiers, frequency converters, and mixers, utilizing Keysight’s unique vector-source-correction technique
-
product
DC/10 MHz 50 GHz USB Thermocouple Power Sensor
U8487A
The U8480 series is Keysight's first power sensor with the capability to measure down to DC (only applicable for U8481A/85A). Now, with an expanded frequency range up to 50 and 67 GHz, the U8480 series allows you to make fast and accurate high frequency power measurements in applications ranging from PNA/MXG calibration to high volume manufacturing.
-
product
Millimeter-Wave Noise Source, Q-band, 33 To 50 GHz
Q347B
The Q347B waveguide noise source (33 to 50 GHz frequency range), allows you to make accurate noise figure measurements on millimeter-wave devices...
-
product
120 GHz Frequency Extender
N5295AX03
The N5295AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
product
Millimeter-wave Operation With Frequency Extenders For P50xxA Streamline VNA
S97560B
Configure an affordable millimeter-wave banded VNA using P50xxA Streamline USB VNAs with this software
-
product
Signal Generators
One of a class of electronic devices that generates electrical signals with set properties of amplitude, frequency, and wave shape.
-
product
Noise Figure Meters
H5M Series
*Frequency range from 10 MHz to 4/20 GHz*Noise Ratio and Gain measurements*Frequency converter measurements with a fixed or external heterodines*Built-in thermostatic YIG preselector*High measurement speed*Extend the NFA solution up to 50 GHz with special downconverter unit*SCPI Language Compatibility
-
product
Power Meters M3M Series
*Frequency range 10 MHz to 18 GHz*Wide Dynamic range −60 dBm to +20 dBm*High Accuracy up to ±0.33 dB*Lightweight and rugged*Simple set-up and usage*Up to 16 hours with built-in accumulator battery
-
product
Complex System Solutions
К2М-100 Series
*Operating Frequency Range: 100 MHz*Measurements per Connection*All S-Parameter Measurement (256 states)*SOLT Calibration*Measurement Profile Save*Full and Cross Measurement Result Analysis
-
product
Test & Measurement Equipment And RF Components
Is necessary for the design, test, manufacture, and debug of radio frequency devices.
-
product
Microwave Amplifiers
MShU Series
*Ultrawide Operating Frequency Range*Small Size*Low Noise Figure*Low Power Consumption
-
product
Supply Adapters
AP Series
*Overflow Relative Noise Temperature and Return Loss Measurement within all Frequency Range*Ultrawide Frequency Range*Small Size*4 Design Structures with Different Connector Types
-
product
Pulse Modulator IM-20
*Wide Frequency Range: 10 MHz...20 GHz*High Pause Power Mitigation: ≥ 70 dB*Signal Radio Impulse < 10 ns*Parallel Data Input*Input/Output Modulator Ports
-
product
Wideband Distributed Amplifiers
A wideband amplifier has a precise amplification factor over a wide frequency range.
-
product
RF Multiplier
Devices that produce an output signal where the frequency is a multiple of the input signal.
-
product
Directional Couplers
Directional Couplers designed by BroadWave provide an accurate method for sampling microwave energy. Available in single and dual configurations. We can offer couplers for most applications including power measurements, signal leveling, and frequency measurements.
-
product
Antennas
The PLA-R and PLA-T are active, battery powered receive and transmit loop antennas for the frequency range 9 kHz - 30 MHz intended for radiated emission testing (PLA-R) and site validation: Normalized site Attenuation, Shielding Effectiveness (PLA-SET consisting of PLA-R and PLA-T)
-
product
Waveguide Harmonic Mixer, 18 to 26.5 GHz
11970K
The Keysight 11970K waveguide mixer is a general-purpose harmonic mixer employing a dual-diode design to achieve flat frequency response and low conversion loss. These are achieved without external dc bias or tuning stubs. Manual operation and computer-controlled hardware operation are simplified because mixer bias and tuning adjustment are not required.