  • Piezoresistive MEMS Shock Accelerometers

    PCB Piezotronics, Inc.

    Piezoresistive shock accelerometers, manufactured by MEMS technology, have low power consumption while still providing +/- 200 mV full scale output. They afford a wider operating temperature range when compared to mechanically isolated ICP® accelerometers. Their frequency response ranges from DC (0 Hz) to 20 kHz. To lessen the severity of response when their resonant frequency is excited, they incorporate squeeze film damping, achieving values of 0.02 to 0.06 of critical.

  • Handheld spectrum analyzer/Signal analyzer

    MICRONIX

    Recently, a lot of equipment have taken the high frequency or microwave technology according to the advancement and the spread of the telecommunication equipment. As a result, the handheld spectrum analyzer to analyze the signal by the frequency domain is necessaries now. The handheld spectrum analyzer is roughly classified into a heterodyne method and a Fourier transform method. The heterodyne method is also called the swept frequency method and makes it possible to measure up to tens of GHz though only for the steady signal. On the other hand, the Fourier transform method is also called the real time method and can handle an unsteady signal though the low measuring frequency range up to tens of MHz. As for our spectrum analyzer or signal analyzer, the MSA300/400 series adopts the swept frequency method, and the MSA500 series adopts both the swept frequency method and the Fourier transform method.

  • Electric Power System Characteristics Test

    Aero Nav Laboratories, Inc.

    This test is also known as the power supply line voltage and frequency variations test. A few of the measured characteristics are: voltage and frequency modulation, voltage spike, and voltage transient recovery.

  • Filters & Attenuators

    ROM-Elektronik GmbH

    Attenuators are used to extend the measuring ranges of our high-frequency measuring devices HFA-3, HFR-4 and Frequency Master IV. They are suitable for measuring higher levels.The measuring range of our high-frequency measuring devices HFA-3, HFR-4 and Frequency Master IV can be adjusted upwards using external attenuators. Available attenuators are 10 dB and 20 dB. The 10 dB attenuator extends the measurement range upwards by a factor of 10 (10x higher radiation level) and the 20 dB attenuator extends the measurement range upwards by a factor of 100 (100x higher radiation level). The attenuators are simply screwed between the antenna and the measuring device.In addition to our high-frequency filter MFF-1, there are also special filters that cover frequency ranges that the MFF-1 does not. Please ask us about your special requirements.

  • Millimeter-wave Receiver

    ZRXL-Series - Radiometer Physics GmbH

    The RPG ZRXxxxL millimeter-wave receiver are optional for the following four-port vector network analyzers: R&S®ZVA24, R&S®ZVA40, R&S®ZVA50 or R&S®ZVA67, and R&S®ZVT20 (not suitable for RPG ZRX500L) with at least four ports. The converters facilitate measurements in the millimeter-wave frequency range. The RPG ZRXxxxL millimeter-wave receiver are available for the frequency bands from 50 GHz to 75 GHz (RPG ZRX75L), from 75 GHz to 110 GHz (RPG ZRX110L), from 220 GHz to 330 GHz (RPG ZRX330L) and from 330 GHz to 500 GHz (RPG ZRX500L). Other frequency bands are covered by other models from the RPG ZRXxxx receiver or R&S®ZCxxx converter series.

  • SGMA Upconverter

    SGU100A - Rohde & Schwarz GmbH & Co. KG

    The R&S®SGU100A SGMA upconverter offers a frequency extension to 40 GHz. When the R&S®SGS100A and the R&S®SGU100A are connected, they act as a single instrument for both remote control and manual operation. The combined instruments offer the same connections as the R&S®SGS100A: one RF output for the entire frequency range and one analog I/Q input for vector modulation. In this setup, tasks are automatically distributed between the two instruments so that users feel as if they are operating a single instrument.Equipped with the R&S®SGU100A, the R&S®SGS100A covers the entire frequency range from 10 MHz to 40 GHz without modulation, and from 80 MHz to 40 GHz with vector modulation.

  • Signal Injectors

    Core Technology Group

    Ideal high performance, low noise compliment to your Circuit Sleuth Frequency Response Analyzer. An injection transformer is used to couple an excitation signal from a frequency source into the feedback loop of a control system. This allows loop gain and phase vs. frequency to be measured, with the loop closed, thus characterizing the stability of the system.

  • AUTOMATED POWER SUPPLIES/SWEEPERS FOR BWO

    Insight Product Company

    nsight Product Company offer Automated Power Supplies/Sweepers specially designed to control mm- and sub-mm wave BWO sources. Those power supplies provides:*highly stable regulated voltages for slow wave structure (anode), filament/heater and control electrodes;*special design to simplify operation with BWO or WRO tubes;*special design to protect tubes during Start/Stop;*unique possibility for fast frequency sweep within entire frequency band;*possibility to use tubes within a PLL frequency stabilization system;*digital control and digital indication of output frequency;*built-in IEEE-488 interface;*multiple possibilities to control output frequency

  • AC Test Transformer

    Shanghai Guantu Technology Co., Ltd.

    How the AC test transformer prevents the overvoltage generated by the frequency conversion series resonance test device is a relatively simple problem, but the overvoltage caused by voltage fluctuation is difficult to appear when the overvoltage protection is set. Generally, the overvoltage of the frequency conversion series resonance test device will appear in the frequency sweep stage of the instrument, that is, in the process of finding the resonance point. Those who have used it know that in the process of finding the resonance point of the frequency conversion series resonance test device, the voltage and frequency have a parabola-like linear relationship. By default, the system finds the high voltage, that is, the apex of the parabola as the resonance point.

  • DAWN Mini ADAQ (Analog-to-CAN)

    HEM Data Corp

    The DAWN Mini ADAQ™ measures a variety of input types including voltage, current, temperature, digital, frequency, PWM, and inclination. It outputs measured data to a CAN network.

  • Digital Multimeters

    Tinsley Precision Instruments

    The Gamma series consists of digital multimeters. They are capable of measuring electrical parameters like current, voltage, frequency, temperature, resistance, diode test and continuity test of the circuit respectively.

  • Digital Power Meters

    Weschler Instruments

    Switchboard meters with one, two or three digital readouts for measuring AC power parameters, including ACV, ACA, frequency, watts, vars, power factor, and phase angle.

  • Double Ridged Waveguide Horn

    DRH30 - RFspin s.r.o.

    Frequency range: 2.5GHz - 30 GHz VSWR (max): < 1.55:1Impedance: 50 O (Ohm)Connector: K female Power (CW / Peak): 25W / 50 W

  • HD Tablet/Touch Analyzer

    BTPRO-8000S - Blonder Tongue Laboratories, Inc.

    The BTPRO-8000S is a professional HD Tablet/Touch Analyzer with a frequency range of 4 to 2610 MHz. The analyzer features a 7-inch 16:9 color display touchscreen, is compact in size, and is lightweight.

  • Heavy Duty Digital Multimeter

    DMM 8007 - Tecpel Co., Ltd.

    1.999 count LCD display. Resistance to 2000 M£[. Frequency to 20MHz. Capacitance measurement. Inductance measurement. Logic Test. Transistor hFE test. Audible continuity test 