Showing results: 91 - 105 of 290 items found.
-
MOCON, Inc.
Headspace analysis is conducted to ensure that the residual oxygen in a product complies with predefined limits. This is a vital part of the Quality Control of Modified Atmosphere Packaging (MAP) products. For packaged foods and other goods, exceeding these limits increases the risk of growth and proliferation of bacteria or mould, which causes spoilage and results in shorter product shelf-life.
-
Rapidox 2112 -
Cambridge Sensotec Ltd
The Rapidox 2112 Multiplex is housed in a 19″ rack mount unit and allows a programmed sequence of gas samples to be fed to a single gas analyser, thus saving money and space requirements.
-
-
COA-3030 -
Shimadzu Corp.
This analyzer is specialized for monitoring waste incinerator compliance with waste processing laws and regulations and guidelines for preventing dioxin emissions.A ratio type infrared gas analyzer is used to measure CO and a magnetic wind type analyzer for O2.
-
Process Sensing Technologies
Michell Instruments’ online hydrocarbon dew point analyzers and portable hydrocarbon dew point tester provide essential quality measurements for natural gas at custody transfer.
-
K9206 -
UEi Test & Measurement Instruments
K9206 is an Industrial Flue Gas Analyzer with wireless handset and built to test combustion systems over 10,000 MBTU/h with high concentration gas levels for extended durations. The K9206 is easily customized to measure 5 toxic gases simultaneously, 6 with direct CO2 measurement or order a preset sensor combination.
-
LI-7810 -
Li-Cor Environmental, Inc.
The LI-7810 CH4/CO2/H2O Trace Gas Analyzer offers high performance methane measurements in a durable, portable design. This makes the LI-7810 a great fit for survey or long-term measurements of soil CH4 fluxes.
-
PI2114 -
Picarro Inc.
The Picarro PI2114 gas concentration analyzer measures hydrogen peroxide levels as low as 4 ppb to help avoid oxidation and safeguard drug stability. Major pharmaceutical, CMO, and isolator companies use Picarro hydrogen peroxide analyzers in high-potency API and biologics manufacturing and in aseptic fill and finish. The PI2114 analyzer is fast and easy to use. It doesn’t need chemicals or consumables. And it requires infrequent calibration and maintenance to minimize operating costs.
-
TRACE S- 1000 -
Atom Instrument
The ATOM TraceS-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.The Model TraceS-1000 with EUVF is a field proven technology that utilizes an excitation wavelength that achieves high detection sensitivity and detector stability. The TraceS-1000 is an excellent fit for applications in the 0-1ppm range and is exceptionally stable, even at concentrations less than 1 ppm. The TraceS-1000 is designed for outdoor installation and use in harsh environments as may be required by the refining (LPG), gas processing (NGL) and natural gas industries.
-
INFICON Holding AG
the market-leading Residual Gas Analyzer (RGA) process monitoring system in the semiconductor industry for over a decade. Now Transpector CPM 3 provides industry leading measurement speed and sensitivity through a field proven pumping and inlet system integrated with a new sensor and electronics. Transpector CPM 3 is the ideal RGA process monitor for new and established semiconductor processes such as ALD, CVD, PVD, and Etch.
-
MEXA-ONE-FT -
HORIBA, Ltd.
The MEXA-ONE-FT Series simultaneously measures concentrations of multiple components, including NH3, N2O, CH4, CO and CO2, in undiluted exhaust gas using the Fourier transform infrared (FTIR) method in combination with a multivariate analysis algorithm. It incorporates HORIBA's proprietary compact interferometer which yields superior performance and high accuracy.The system complies with NH3 testing requirements of Euro VI, the EU regulation for heavy duty emissions testing.The MEXA-ONE-FT can be calibrated according to customer requirements with up to 6 component sets to cover a wide range of applications.FTIR spectroscopy allows the direct measurement of NO2 emissions and the independent quantification of individual hydrocarbon species. This makes the MEXA-ONE-FT system an ideal solution for detailed research and development tasks.Due to the measurement principle, the time-consuming daily span gas calibration is omitted.In addition, usability and flexibility are realized by “HORIBA ONE PLATFORM” which enables to extend the system with other ONE analyzers to a complete solution suitable for both certification and R&D purposes.
-
ABB Ltd.
Intelligent Sample Gas Conditioning.
-
iso DUAL INLET -
Elementar Analysensysteme GmbH
Dual inlet technology is the most precise, accurate and sensitive technique for carbonate and water analysis. Because of this, the iso DUAL INLET has a unique role in the paleoclimate applications where instrumental precision contributes directly to the precision of paleoclimate models. Whilst the world's climate continues to behave erratically, we must know what has happened in Earth's history before we can attempt to predict what will happen in the future. To elucidate this complicated story, the iso DUAL INLET is a valuable tool for paleoclimatologists to build a detailed picture of the past to better inform policy makers who might just be able to influence the future of our planet.
-
Verax SSG & SSL -
JP3 Measurement, llc
They provide rapid and reliable measurement of key compositional and physical properties for a wide variety of natural gas analysis (Verax SSG) and liquid (Verax SSL) applications in crude oil, condensates, NGLs and refined fuels.
-
SGA-1000 -
Atom Instrument
The ATOM SGA-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.ATOM Instrument offers the most versatile total sulfur analyzers available. The ATOM SGA-1000 has the fastest analysis time of any commercially available analyzer allowing user-defined, multiple cycle averaging to improve analyzer performance. The analyzer operating software is both intuitive and user-friendly. In addition, the ATOM SGA -1000 only requires bottled air for normal operation and does not require installation in a shelter.