Filter Results By:

Products

Applications

Manufacturers

Gas Analyzers

determine the quality and quantity of a gas or gas mixture.

See Also: Gas Analysis, Residual Gas Analyzers, Gas Sensors


Showing results: 121 - 135 of 320 items found.

  • Gas Filter Correlation Carbon Dioxide Analyzer

    Model T360 - Teledyne Monitor Labs

    The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.​The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software​.​​​

  • ​Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300 - Teledyne Monitor Labs

    The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software​.​​

  • BET Flowing Gas Surface Area Analyzers

    SA-9600 Series - HORIBA, Ltd.

    The surface area of a material is, in many cases, as important as the chemical properties. As particle size decreases, surface area increases. Porosity of materials - from micropores to macropores - contribute even more to the total surface area. The interface at the surface is what defines how a solid reacts to other substances, be they gases, liquids, or solids.Surface area can impact shelf life, stability, dissolution and efficacy of pharmaceutical powders and tablets. Likewise, surface area can affect the rheological properties and hiding powers of pigments, paints, and coatings. It has a significant impact on the ability for materials like catalysts, adsorbents, filtration materials and air separation products to react in the designed application. Ceramics used in applications ranging from; dinner plates, to dental implants, to electronics, all are affected by surface area.

  • CO2 Isotope/ NH3 Trace Gas Analyzer

    LI-7825 - Li-Cor Environmental, Inc.

    The LI-7825 measures the four most abundant CO2 gas isotopologues in air and reports δ13C , δ17O , and δ18O with high precision and accuracy.

  • Precisive® 5 Application Specific Gas Analyzers

    MKS Instruments

    The Precisive® Gas Analyzer is a real-time gas analyzer based on MKS' unique Tunable Filter Spectroscopy (TFS™) platform. The Precisive suite of products are calibrated for the measurement of a wide range of gases across multiple process industries. The real-time, continuous measurement capability provides immediate analysis ensuring control of critical process parameters.

  • Mid-Range Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300M - Teledyne Monitor Labs

    The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance from low to high range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​​

  • ​Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer​

    Model T360M - Teledyne Monitor Labs

    The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

  • FTIR Exhaust Gas Analyzer Dilute Measurement Type

    FTX-ONE-CL - HORIBA, Ltd.

    Offers a 5Hz sampling rate and simultaneously measure the concentrations of multiple components including NH3, CH4 and CO2, engine diluted exhaust gas using the Fourier Transform Infrared (FTIR) method in combination with multivariate analysis algorithm.

  • FTIR Exhaust Gas Analyzer Direct Measurement Type

    FTX-ONE-CS/RS - HORIBA, Ltd.

    The FTX-ONE offers a 5Hz sampling rate and simultaneously measure the concentrations of multiple components including NH3, CH4, and CO2, from (engine) direct exhaust gas using the Fourier Transform Infrared (FTIR) method in combination with multivariate analysis algorithm.

  • Ultra-Low Range ​Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300U - Teledyne Monitor Labs

    The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​​

  • Trace Moisture Analyzers for Natural Gas Quality and Petrochemical Applications

    Process Sensing Technologies

    Michell Instruments’ process moisture analyzers provide continuous, online monitoring of dew point and trace moisture content.

  • Exhaust Gas Analyzer for the Measurement of Petrol-, CNG-, and LPG- Powered Vehicles

    MET 6.1 | VP 135117 - Maschinenbau Haldenwang GmbH & Co. KG.

    The MET 6.1 exhaust gas analyser is designed for the measurement of petrol-, CNG- and LPG-powered vehicles as well as the precise analysis of the gas components HC, CO, CO2, O2 with lambda value calculation. The MET 6.1 stands out for its innovative condensate separation thanks to an active water separator. In addition, low weight, compact design and short warm-up time ensure easy handling.

  • Optical Modulation Analyzer

    OMA - Quantifi Photonics Inc.

    In partnership with Tektronix, we bring you a high-performing and flexible OMA system that will meet your requirements today and into the future.With the market-leading performance of Quantifi Photonics’ IQRX coherent receiver and the scalable architecture of Tektronix’s high-performing oscilloscopes, you’ll get the most out of your investment. Use the stack as a single 70GHz OMA system, or use it as four independent oscilloscopes.Whether you are working with 100G coherent transceivers or 1 Terabit long haul communication systems, our OMA can be configured to suit your exact requirements.

  • Frequency-Resolved Optical Gating Pulse Analyzer

    IQFROG - Quantifi Photonics Inc.

    The IQFROG measures pulse intensity and phase in both spectral and temporal domains, yielding a complete pulse characterization. With its long delay arm and high resolution spectrometer, it measures chirped pulses up to 50 ps wide, or up to 10 ps wide if the pulse is transform limited. The IQFROG is available in 1.0 and 1.5 micron wavelengths.

  • Optical Spectrum Analyzer Module

    OSAPXIe - Quantifi Photonics Inc.

    OSAPXIe enables new measurement capabilities in PXI for truly effective mixed-signal testing. Conduct all your DUT characterization from one platform and spend less time switching cables and patchcords between instruments.

Get Help