Showing results: 1396 - 1410 of 1865 items found.
-
40-850A-014 -
Pickering Interfaces Ltd.
The 40/42-850A-014 is a PXI/PXIe 4-channel multiplexer with FC/APC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
42-850A-014 -
Pickering Interfaces Ltd.
The 40/42-850A-014 is a PXI/PXIe 4-channel multiplexer with FC/APC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
42-204-001 -
Pickering Interfaces Ltd.
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
40-204-002 -
Pickering Interfaces Ltd.
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
42-204-002 -
Pickering Interfaces Ltd.
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
42-788-132-T -
Pickering Interfaces Ltd.
The 40-788-132-T (PXI) and 42-788-132-T (PXIe) are dual failsafe SP10T 22 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
DAQM908A -
Keysight Technologies
40 Channel Single-Ended Multiplexer Module for DAQ970A and DAQ973A. Single-wire switching for common low applications with scan speed of up to 80 ch/s.
-
42-785-572 -
Pickering Interfaces Ltd.
The 40-785C-572 (PXI) and 42-785C-572 (PXIe) are dual failsafe SP6T 67 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-472-E -
Pickering Interfaces Ltd.
The 40-785C-472-E (PXI) and 42-785C-472-E (PXIe) are dual SP4T 67GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
40-785C-572 -
Pickering Interfaces Ltd.
The 40-785C-572 (PXI) and 42-785C-572 (PXIe) are dual SP6T 67GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
42-785C-472-E -
Pickering Interfaces Ltd.
The 40-785C-472-E (PXI) and 42-785C-472-E (PXIe) are dual failsafe SP4T 67 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-572-E -
Pickering Interfaces Ltd.
The 40-785C-572-E (PXI) and 42-785C-572-E (PXIe) are dual SP6T 67GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
42-785C-572-E -
Pickering Interfaces Ltd.
The 40-785C-572-E (PXI) and 42-785C-572-E (PXIe) are dual failsafe SP6T 67 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-472-T -
Pickering Interfaces Ltd.
The 40-785C-472-T (PXI) and 42-785C-472-T (PXIe) are dual failsafe SP4T 67 GHz with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-472-TE -
Pickering Interfaces Ltd.
The 40-785C-472-TE (PXI) and 42-785C-472-TE (PXIe) are dual failsafe SP4T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.