Showing results: 481 - 495 of 1185 items found.
-
VFL159124-048 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 160 Pin Female LFH to QuadraPaddle Leads, 28AWG Twisted Pair, 160 T/P's, SHARED GROUNDS 80 T/Ps, 168 connection points, CONN: 780009-02, VPC Contact 610138216 - QP RCV (22AWG-28AWG) (5 AMP/25 mΩ MAX), 48" length.
-
Greenlee Tools
A cable insulation resistance test is a test that is performed by applying 500 V or more between the conductor and ground and measuring the resulting leakage current. An insulation resistance tester is a test instrument that measures current that leaks through the insulation into ground. Insulation resistance tests can be performed with insulation multi- meters (IMMs) or megohmmeters. Insulation resistance testers are calibrated to display megohms (MΩ) of resistance. A satisfactory insulation resistance measurement should be in millions of ohms.
-
8002 -
VECTOR Electronics and Technology, Inc.
Interleaved buses pattern, ideal for wire-wrap applications. Power and ground buses etched onto wiring side only. Bus surfaces solder coated for user convenience. Mount components with 0.3”, 0.6” & 0.9” lead spacing.I/O area with square solder pads for connector mounting. Single-sided with no etch and plating on reverse side.
-
8008 -
VECTOR Electronics and Technology, Inc.
Pad-Per-Hole & Planes 2 Sides. Unique circuit pattern features full voltage & ground planeson both sides with isolated plated-thru holes. 0.080” diameter, isolated solder pad around holes oncomponent side. Plane surfaces solder-coated for user convenience. SMD cap positions for discrete decoupling capacitors.
-
4624-4 -
VECTOR Electronics and Technology, Inc.
120 contacts (60 each side) on 0.050" centers. Pad-Per-Hole & Peripheral Buses. 32-bit ISA format. Universal tab fits both 3.3V and 5V tab notch patterns. Mounting bracket included. Peripheral buses for voltage and ground distribution. I/O mounting area for D-sub and ribbon cable connectors.
-
8801-6 -
VECTOR Electronics and Technology, Inc.
100 Gold plated edge contacts (50 each side)on 0.125"(3.175mm) centers. Pad per hole (square) both sides. I/O mounting area for ribbon cable header.Row and column legends provided. S-100 Form Factor.Pin 1 and 51 committed to power. Pin 50 and 100 committed to ground.
-
Greenlee Tools
*Measures AC current from 1 to 2000 Amps on system voltages up to 500kV line-to-ground*Stores the last 4 readings*Dual measurement modes, peak hold and real time*Takes spot-load checks with ease*Verifies phases are balanced*Versatile for overhead and underground applications*Compact, lightweight design
-
Santronics, Inc.
This sensor can be used to troubleshoot any DC circuit with voltage ranging from 6-50 volts DC. It features an audio and visual alert and a sharp, rust-proof, stainless steel tip that works great for penetrating insulated wires. This sensor also features an extended ground lead with an extra-large alligator clip to ensure a good connection.
-
1394A -
Ballentine Laboratories, Inc.
Nominal Heater Current: 5 mA rms,Max. Heater Current: 7.5 mA rmsCouple Output: 7 mV ± 12% at nominal heater current.Couple Resistance: 8 W ± 20%.Maximum DC Reversal Error: ± 0.04%Couple Output Voltage to Heater (ground): ± 50 V (dc + acpk-pk) max.
-
Soken Electric Co. Ltd
Suitable for preventive maintenance of gapless arresters.By simply clamping around the ground wire of an arrestor with a clamp CT, it detects leak current and leak current resistance components.
-
Bestone Industrial Ltd.
This groundmeter is designed for testing ground wire of electric power net, as well as earth voltage test in the fields of household electric power system and delectric appliance application.
-
4613-1 -
VECTOR Electronics and Technology, Inc.
62 contacts (31 each side) on 0.100" centers. Voltage and ground buses around board perimeter on both sides. Auxiliary bus line along lower edge of board on both sides. I/O mounting area for 37-pin D-sub and ribbon cable connectors. Mounting bracket and hardware kit included (P/N HD36B).
-
8011 -
Sealevel Systems, Inc.
The 8011 digital I/O interface provides 8 optically isolated inputs and 8 Form C relay outputs. The inputs protect the PC and other sensitive equipment from spikes and ground loop current that can be generated in industrial environments, while the outputs provide higher current capabilities (up to 2A) and are optimized for 24V operation.
-
8012e -
Sealevel Systems, Inc.
The 8012e Low Profile PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
pQA -
Hiden Analytical Ltd.
The Hiden pQA portable gas analyser is a versatile mass spectrometer and offered with a range of interchangeable sampling inlets to suit a broad application range. MIMS inlets are offered for analysis of dissolved species in ground water, sediments, fermentation cultures, soil samples, and general applications where analysis of dissolved species in liquid sample is required.