AFJ Instruments
Through different ways of coupling between luminaries and humans, a level of exposure of a person to electromagnetic fields can be derived. One part of the exposure is based on capacitive coupling between lighting equipment and person. This creates induced internal electric field that must be evaluated using an EMI receiver and a Van Der Hoofden test head.
-
ShibaSoku Co., Ltd.
This system is suitable for DC testing of IGBT, IGBT module (1in1~7in1). Built-in hi-current switching relay circuit inside test head, it is capable ofDC testing from device itself to module. Highly accurate repeatability testing is available by high speed rise time which is suppressed its heat in hi-current
-
350C and 350CD -
Scitec Instruments Ltd
Model 350 is a high stability variable frequency optical chopper. The basic system consists of a control unit and a chopping head. It is supplied with four chemically blacked 30 mm diameter discs. These discs are of 2, 4, 10 and 40 slots and allow operation over the frequency range 10 Hz to 10 kHz.
-
Fieldpiece Instruments, Inc
Portable dual port manometer accessory head for use with our modular multimeters (DMMs) and instruments. Measures gas pressure, static pressure and pressure differential. The ADMN2 includes a zero adjust and the Auto Power-Off (APO) function to conserve battery life. Disable APO for data logging. The ADMN2 measures pressure between -60inWC and 60inWC (inches of water column) and -150.0 to 150.0 mBar. The ADMN2 also measures P1 or P2 pressure readings and calculates the difference between P1 and P2. Take static pressure measurements using the resolution mode of 0.01inWC or 0.01mBar.
-
PDS-TSHD -
Teledyne Marine PDS
TELEDYNE PDS for Trailing Suction Hopper Dredge (TSHD) is designed to meet the dynamic demands of today’s dredge operator.TELEDYNE PDS-TSHD is an easy to use monitoring system that visualizes the dredge process real time in 3D, top, and profile views. The system gives an instant overview of the horizontal and vertical position of the suction tube, the vessel outline, and the dredge heads along with the surveyed depths, design, and dredged depth. Dredged areas are shown in various views, which are updated as soon as new data is available. Alarms can be generated for safety of the operation and to maintain the quality of the dredge progress.
-
Bowers Group
Bowers’ XT3 digital internal micrometers offer an ergonomic design - including a larger and clearer LCD display - along with IP67 electronics protection, proximity output; allowing bi-directional communication giving greater flexibility for data acquisition and storage. The extended mechanical travel of the XT range means that special heads can also be manufactured to accommodate users most awkward measuring problems. If you need something bespoke, reach out to us at sales@bowersgroup.co.ukIf you prefer the analogue approach, then we offer the same size range in our XT Analogue format.
-
M-140HC -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Easy!:Measurale Load Current at high voltage CV/CVT cables with grounding lines for shield phase.*Epoch-Making!:Can measure phase current of CVT cable just by putting CT head on to the conductors as well as CV cable just by clamping CT to the conductors in a lump.*Low Cost!:Can measure line/leakage current in the same manner as ordinary clamp meters.
-
NC-60F/RS-1300N -
NAPSON Corp.
*Global standard for non-contact measurement of ITO film, Metal thin films on flat panel*Automatic X-Y and Z (eddy current probe head) axis moving mechanism*Compatible with Loading robot for fully automatic measurementOption :*Integlate to combined system (film thickness meter, etc)*Add 4 point probe measurement unit : RT-3000
-
10780C -
Keysight Technologies
The Keysight 10780C is a highly-sensitive, lowest-cost Keysight receiver used with laser interferometer positioning systems. One receiver is used per measurement axis (including wavelength tracker). Configured with Keysight electronics, laser heads, cables and optics, the Keysight 10780C receiver allows you tailor a precise positioning system for your exact application requirements.
-
M-HD-360A -
Fuzhou Metricu Technology Co Ltd
Analog camera testHD-TVI camera test, HD-CVI camera test, AHD camera testDC12V 1A power outputVGA input, support 1920 x 1200P 60FPSAuto HD, auto recognize HD coax camera type and resolutionUTP cable test, detect the near-end, mid-end and far-end fault point of the network cable crystal head
-
LF1 set -
Langer EMV-Technik GmbH
The LF1 near-field probe set consists of 4 shielded near-field probes used during the development process for emission measurement of longwave, medium wave, and shortwave frequencies on electronic devices. The probe heads of the LF1 set are designed for incremental detection of sources of electromagnetic interference on assemblies. First, the electromagnetic interference of the assembly is detected by the LF-R 400 probe from up to 10 cm. Then probes with higher resolution like the LF-B 3, LF-U 5 and LF-U 2.5 are used to more precisely detect any source of interference. The probe heads are designed for taking measurements at single pins and larger components. Near-field probes are small and handy. They have a current attenuating sheath and, therefore, are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. The H-field probes do not have an internal terminating resistance of 50 Ω.
-
QTOUCH1404C -
Qmax Test Technologies Pvt. Ltd.
The Prober Test System is capable of movement in XYZ directions with fixed angle (θ) and dual probe heads (further expandable up to 4 ) . The system has in-built high resolution Vision Camera for easy monitoring of probe needle contact. The prober supports automatic fiduciary recognition. The system has built –in linear encoders to achieve higher precision.
-
iTrans2 -
Teledyne Gas & Flame Detection
The iTrans2 infrared gas detector employs an intelligent electronics platform to provide one or two points of detection from a single head for maximum flexibility, superior performance and lower installation costs. With the optional HART Communication Protocol, the iTrans2 offers remote diagnostics, set-up or calibration by superimposing a high-frequency current across the industry standard 4-20mA analog line.
-
RMS-1000 -
ECOPIA
Accurate and powerful performance. - Possible to get much accurate resistivity value by taking 8 raw data. - Good to check ohmic contact by flowing forward and reverse current.2. We provide various sample mounting board and probe head and tips.3. We have an optional item which can measure in variable temperature. - Room Temperature ~ 300dC.
-
6HP-9060 -
Prokit's Industries Co., Ltd.
Switchable X1/X10/X100 attenuation with reference switch positions. Break-resistant center conductor & wide compensation range. Flatter response, sharper leading edges. Faster rise time and replaceable cable probe head tip and ground lead. Max. input voltage: 600V/1200V (DC-peak AC). Includes BNC adapter, IC tip, insulating tip & trimming tool.