Showing results: 346 - 360 of 583 items found.
-
PS270-1U -
Axiomtek Co., Ltd.
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 18A (0.5A min)**+3.3V, 16A (0.5A min)**+12V1, 16A (1A min)**+12V2, 10A (1A min)**-12V, 0.8A**+5Vsb, 2.5A*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CSA 22.2 NO.60950-1, IEC, UL, NEMKO, CE*Dimensions: 150 x 81.5 x 40.5 mm*Compatible with Axiomtek products: AX61120 / AX60530
-
SCR ELEKTRONIKS
The test system is a special version of the thermal test test system in the sense that the test jig is primarily designed to hold and connect multi pole MCBs for thermal verification so that each pole can be verified to trip within the IEC time band after the MCB has been riveted. This test ensures the trip verification of MCB so as to trip all the 4 poles at once when overload is detected in one single pole. In short, this is a verification-only bench.
-
SORAS LS -
PSE Instruments GmbH
In certification laboratories for photovoltaic modules, steady-state solar simulators are mostly used for stabilization / light soaking tests (MQT 19) and hot-spot endurance tests (MQT 09) according to IEC 61215 and IEC 61730. An initial stabilization is required for all PV modules that undergo a standard test procedure. For the hot-spot endurance test (MQT 09), it is important that the operator has easy access to the front and back site of the module. During the test, it is necessary to shade one cell after each other to take infrared pictures, which requires good visibility of the entire back side. Our swiveling module holding system enables easy access to the front and back side of the module.
-
TEM -
Mess- & Prüfsysteme GmbH
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
Spark Family -
Larson Davis, Inc.
Spark® series dosimeters are compact, affordable and tamper-proof personal Noise Dosimeter that measures the following to applicable IEC and ANSI standards:*Noise Exposure: Multiple Dose; Projected Dose; Time Weighted Average; (all with 4 user selectable combinations of Exchange Rate, Threshold, Criterion Level and Criterion Time); Sound Exposure Level*Sound Levels:; Leq; Lmax; Lmin; Lpeak/Luwpk, SEL and more*Time and number of events above Ceiling Level (115 dB) and Peak Level (140dB)
-
PS400-XP2 -
Axiomtek Co., Ltd.
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 20A (0.5A min)**+3.3V, 20A (0.3A min)**+12V1, 16A (1A min)**+12V2, 16A (1A min)**-12V, 0.5A**+5Vsb, 2.5A (1A min)*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CS22.2 NO.60950-1, IEC, UL, NEMKO+CB, CE*Dimensions: 150 x 140 x 74 mm*Compatible with Axiomtek products: AX61221/AX61222/AX60501/AX60551/AX60552/AX61400/AX6145/AX6156/AX61492/AX61220
-
DE-5030 -
DER EE Electrical Instrument
Earth resistance range0~12 / 0~120 / 0~1200 Normal operation conditionsBattery voltagein range of "BATT.GOOD" Earth voltage measurementmax. AC 30V Output current3mA Response timewithin 1 sec. Insulation resistancemin. 100M / DC1000V between input terminals and case Withstand voltageAC3700V (50 / 60Hz) for 1 min. between input terminals and case Battery Check Battery1.5V x 4 Safety standardIEC 61010-1 CAT.III 300V IEC 61557, IEC61010-031
-
CMRI 1010 -
Signals & Systems India Private Limited
Common Meter Reading Instrument (CMRI) is a handheld computer used to download data from electronic tri-vector meters, supporting different protocols like IEC, ANSI and PACT. CMRI is also compliant to IS-15959/ DLMS (IEC-62056) standard. CMRI can be interfaced with the portable printer for spot billing applications.SANDS CMRI-1010 comes with LCD Graphical (3.5” TFT) & 15Line x 40 Characters visibility is rugged to withstand drop on to concrete and waterproof. CMRI is available with a memory size of 512 MB.
-
HS-175 -
Standard Electric Works Co., Ltd
● Triangular-shaped design keeps the sections aligned during extension and retraction.● Push button release for stick extension and retraction. ● Telescopic design allows for easy assembly, storage and transportation.● Withstands voltage rating of 100kV from 30cm for 1 minutes. ● Universal end fitting accepts a wide variety of standard attachments.● Highly visible yellow tip section.● Easy-to-replace sections.● Carrying bag included. ● Optional integrated height measurement scale.● Complies with IEC 62193 safety standard.
-
TDK RF Solutions Inc.
TDK Test Services offers testing to domestic and international EMC test regulations, including IEC, ISO, CISPR, and SAE. Test services are offered in our 3m semi-anechoic chamber, 3m fully-anechoic chamber, 10-meter open area test site, and our shielded conducted test chamber.
-
CX-15 -
Shenzhen Chuangxin Instruments Co., Ltd.
The Impact Test Ball is a specially machined ball to test impact resistance according to IEC, CSA and UL Standards. It is made of chrome-plated-steel for durability, and is fitted with an eyelet to facilitate testing for pendulum applications. Eyelet is threaded to the ball to allow attachment of a handle or force gauge. Weights are closely controlled.
-
ELMA Electronic, Inc.
Elma implements quickly and easily scalable, robust 19'' subracks, card cages or rackmount chassis for the use in just about any industry or environment: Industrial automation, test & measurement, transportation, energy, defense, communications and medical. The products of Elma Electronic support standards such as IEC, IEEE or AdvancedTCA.
-
Weice Testing Instrument Co.,Ltd.
The WTS series of salt spray chambers are manufactured and designed to meet the high quality requirements and standards, such as ISO, JIS, DIN, ASTM, IEC, GB and SAE. They are used to test the resistance capabilities of materials eroded by brine, these materials may be used in Electrical Appliances, Electrical Wire, Accessories, Luminaires etc.
-
EM 4058 -
Scope T&M Pvt, Ltd.
earth tester is a digital, microprocessor controlled instrument that allows to measure the earth resistance and ground resistivity (using Wenner´s method), as well as to detect parasitic voltages present in the ground. This instrument is suitable to measure earth systems in power substations, industries, distribution networks, etc., according to IEC 61557-5.
-
Sanwood Environmental Chambers Co ., Ltd.
Rain Test Chamber is used to test anti-rain and waterproof performance for products, the products such as .steam locomotive lamps, wiper performance, waterproof bands, motorcycle instruments, defense industry, navigation systems, missiles, radar cone top, aerospace industry, IEC IP code specifications that need an additional discussion.