Filter Results By:
Products
Applications
Manufacturers
- TEAM SOLUTIONS, INC.
product
PCI Bus Analog Output Board, 4 Isolated Outputs, 14 Bit
APCI-3501-4
4 analog output channels Optical isolation 500 V Settling time 30 µs typ. 14-bit resolution (13 bit for 0-10 V) Output voltage: ±10 V, 0-10 V (switchable through software) Output voltage after reset: 0 V Each output channel has its own ground line (without optical isolation from the others) Driver capacity: 5 mA/500 pF Short-circuit protection, EMI filters Noise neutralization of the PC supply Creeping distance: 3.2 mm acc. to DIN VDE 0411-100 Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary2 digital input channels, 24 V, isolated 2 digital output channels, 24 V, isolated Noise immunity Test level: ESD: 4 kV Fields: 10 V/m Burst: 4 kV Cond. radio interferences: 10 V
-
product
Immunity
RF coupling
is used for the conducted measurement of the immunity according to IEC 62132-4.
-
product
Immunity
EFT coupling
s used for direct-contact measurements of impulse immunity in IC pins, according to IEC 62215-3 and IEC 61000-4-4.
-
product
Immunity
ESD coupling
is used for conducted coupling of Langer ESD pulses (200ps rise time) into ICs.
-
product
Immunity DC
PGA 1240
The power generator PGA 1240 is suitable for EMC testing in accordance with standard IEC / EN 61000-4-16 in the frequency range from DC to 300 kHz.
-
product
Transient Immunity Tester
KES7700
Transient Immunity Tester KES7700 Series are transient surge tester that utilizes a compact unit system. A surge generator circuit is installed for each pulse unit as the tester meets the requirement of ISO7637-2, ISO7637-3, ISO16750-2, JASO D001, SAEJ1113, and other standards. The KES7700 Series meets a broad range of independent automobile manufacturer standards as well.
-
product
EFT Immunity Measurement
EFT61000-4
EFT immunity tester EFT61000-4 is specially designed according to the characteristics and requirements of EFT measurement and it is an ideal disturbance source of EMS measurement. They have fine performance, such as high stability, high reliability, easy to use etc. It meets the standard requirements of IEC 61000-4-4, EN 61000-4-4, GB/T17215.301, GB/T17215.322 and GB/T17626.4. EFT61000-4 has LCD display in both English and Chinese.
-
product
Ultra-Compact Immunity Tester
AXOS5
The AXOS5 is an ultra-compact immunity tester that performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.The actual EUT power mains voltage and current are indicated in the display. Using the Electronic-Fuse function, the user can set an upper limit for EUT power mains current. This feature is useful to protect the EUT from unnecessary damage.Whether you test to the IEC 61000 series “CE Mark” standards, the IEC 60601 Medical Device standards, or any number of telecom and product specific standards, the AXOS5 tester is your one stop test station for everything from precompliance to full compliance to product development testing.A wide range of cost-efficient Coupling / Decoupling Networks for symmetrical and asymmetrical data- and signal-lines is available as an option.
-
product
Ultra-Compact Immunity Tester
AXOS8
The AXOS8 is an ultra-compact immunity tester that performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.The actual EUT power mains voltage and current are indicated in the display. Using the Electronic-Fuse function, the user can set an upper limit for EUT power mains current. This feature is useful to protect the EUT from unnecessary damage.Whether you test to the IEC 61000 series “CE Mark” standards, the IEC 60601 Medical Device standards, or any number of telecom and product specific standards, the AXOS8 tester is your one stop test station for everything from precompliance to full compliance to product development testing.A wide range of cost-efficient Coupling / Decoupling Networks for symmetrical and asymmetrical data- and signal-lines is available as an option.
-
product
Immunity Testing Systems
CIS Series
The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes an ACS series power amplifier, coupling/decoupling Network (CDN), directional coupler, 150Ω to 50Ω adapters, power attenuators, cables and [optional] CSAT software. These systems, when properly configured, are capable of testing your products to all levels given in IEC 61000-4-6 up to 230 MHz. You can choose from three systems. Follow the links below for detailed information, including a comprehensive datasheet listing system specs.
-
product
Immunity Development System
Used for EMI suppression in printed circuit boards during the development phase. The developer can use the E1 set to quickly identify the causes of burst and ESD interference. This allows the developer to design suitable measures to solve the causes of the interference. It can also be used to test the effectiveness of the measures taken.
-
product
Electromagnetic Immunity Scanner
SmartScan 350
Reproducing similar soft or hard failure to the gun test - Flexible automatic failure detection module - Susceptibility map generation- Automatic report generation- Flexible scan area editor (SAE)- Flexible display (3D, histogram)- Matlab support- Expandability (EMI scan, phase measurement, NFFF transformation)- Custom design probes
-
product
Electromagnetic Immunity Scanner
SmartScan BASIC
The BASIC is manually operated system for performing susceptibility scanning at the system level with minimal data storage capability. This system includes:1. Up to 8kV (optional. 4kV base) pulse generator for ESD susceptibility testing- Camera and camera shutter to take DUT picture and failing spots- Control computer2. Up to 8kV Probe Sets:- 1mm Hx/y Field Probe- 5mm Hx/y Field Probe- D=8mm Hz Field Probe- D=8mm Ez Field Probe- Contact API for custom design probes3. Manual input of testing location and failing condition over the DUT to be included in final report.
-
product
RF swept immunity package
EMiSweep
This is a flexible Windows immunity package which provides the utilmate flexible Graphical User interface. Other visual aids provides a swept as well as spot frequency assessment.
-
product
Conducted Immunity Test System
Conducted RF immunity tests acc. to IEC/EN61000-4-6 and BCI tests acc. to ISO 11452-4 and MIL-STD 461 CS 114 Signal generator,RF-power amplifier, RF-power meter and directional coupler (optional) in one 19”-caseStand-alone operation possible with optional available netbookControl-software includedMost important parameters are shown on an integrated displayAutomatic EUT-monitoringOperation via USB port of a PC or NotebookComplete range of CDNs available
-
product
RF Conducted Immunity Testing
AR RF/Microwave Instrumentation
If you are tired of mixing and matching various components, try AR’s complete line of RF Conducted Immunity Test Systems. We now make one fully configured and standalone CI System from 4 kHz to 400 MHz with output powers designed to meet the latest commercial, custom, and military standards. In addition, AR provides configurable systems meeting your specific requirements of increased power and frequency range.
-
product
Conducted Immunity Test Systems
Includes library of 1000+ pre-entered Automotive and Industry Standards’ test routinesOperate as a free- standing system using the included monitor, keyboard and mouse, or control via LANVery easy to modify existing tests or build new test sequencesModels from 25A to 200A continuous output current available
-
product
EMI EMC test Solutions for Immunity
Scientific Mes-Technik Private Ltd
EMI EMC test Solutions for Immunity
-
product
Lightning Testing and Surge Immunity Testing
Keystone Compliance offers engineering services for standard and custom lightning transient immunity testing requirements and surge immunity testing requirements. Lightning testing can be completed in single-stroke, multiple-stroke and multiple-burst testing. Direct lightning testing is typically required for exterior aircraft systems. Indirect lightning testing is required for most aircraft electronics, both internal and external. Indirect lightning simulates secondary currents and voltages that travel through circuitry and cabling. The testing is also referred to as a surge immunity test.
-
product
Impulse Magnetic Field Immunity Tester
IMF61000-9
IMF61000-9 impulse magnetic field immunity tester is high performance test instrument which special designed for to do impulse magnetic field immunity test and fully meet IEC61000-4-9, EN61000-4-9 and GB/T17626.9 standards, also it come with high intelligent, high stable performance and easy operation characteristics.
-
product
Software for Immunity Test METES-EMS series
METES-EMS is software for Automated Test Solution to meed Immunity Std. each for Keys : Support for latest Windows OS Access via USB/LAN interface to measurement equipments to achieve
-
product
AR Radiated Immunity Test Systems
AR RF/Microwave Instrumentation
We have complete standard and custom test systems that perform entire radiated immunity tests with just the press of a few buttons. Everything you need – amplifiers, antennas, couplers, signal generators, system controllers, receivers, and more, along with the software to control it – all in one comprehensive system.
-
product
RF Conducted Immunity Test System
RFCI61000-4-6
RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.
-
product
Microwave Amplifiers For Immunity and Wireless Testing
AR RF/Microwave Instrumentation
AR’s microwave amplifiers are just as tough and dependable as our RF amplifiers, and they are backed by the same comprehensive warranty. Our microwave amplifiers offer the hard-to-find combinations of power and bandwidth in frequency increments and power output you need for today’s test applications.
-
product
Damped Oscillatory Magnetic Field Immunity Tester
DOMF61000-10
DOMF61000-10 damped oscillatory magnetic field immunity test system included damped oscillating wave generator and single ring coil, it’s designed for to do damping oscillation magnetic field immunity test and fully meet IEC 61000-4-10, EN61000-4-10 and GB/T 17626.10 standards requirement.
-
product
Multifunctional Immunity Test System For Automotive Electronics
EMS-ISO7637
EMS-ISO7637 automotive multifunctional immunity test system meet newest ISO7637-2 requirement of
. This standard was issued by international organization for standardization, and this system included all of ISO-7637 required test waveform and meet most of automotive manufacturer’s requirement for automotive electronic immunity test. -
product
IEC61000-4-4 4.8KV Electrical Fast Transient Immunity Generator
EFT-404BX
Shenzhen Chuangxin Instruments Co., Ltd.
EFT-404BX Impulse Generator is fully met requirements of the standards IEC61000-4-4 and GB/T17616.4.
-
product
Coupling Decoupling Network for Conducted Common Mode Immunity Testing According to IEC 61000-4-6
CDN
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
product
TDK Software
TDK Software - Testlab, Emissions Lab, Cundicted Immunity Lab, Radiated Immunity Lab, EUT Monitoring Lab, GTEM Emissions Lab
-
product
EMC Testing Services
Our sophisticated technology can meet the diversified needs of customers. Component Tests: Immunity, Radiated Immunity, ALSE, TEM cell, Bulk Current Injection, Stripline, Conducted Immunity, Transient Immunity, Power Supply Variations, Electrostatic Discharge Emissions, Radiated Emissions, Conducted Emissions, Transient Emissions. Vehicle Tests - Radiated Immunity, Radiated Emissions.
-
product
RF Shielded Chamber
MIL-STD
A high performance RF-shielded chamber specifically designed for radiated emissions testing in accordance with MIL-STD-461E/F. This chamber can be used for conducted emissions, conducted immunity, radiated emissions, and radiated immunity testing.