Filter Results By:

Products

Applications

Manufacturers

Showing results: 226 - 240 of 267 items found.

  • H.V. Multifuntion Phasing Sticks

    PC7k, PC11k, PC22k, PC33k, PC44k - Standard Electric Works Co., Ltd

    ● No user’s assembled parts.● Dual color-coded scale (%, Vac).● Neon indicator when >1200Vac.● Lightweight, robust & compact.● Carry case included.● Compare between phases.● Measure and test phase to earth.● High quality fiberglass wound rod.● Self powered operation. No battery required.● DC version available.● Measure phase to phase.● Hi immunity to interference fields.● Suitable for indoor and outdoor use.● Current is limited to ±1 milli-ampere.● Grounded or ungrounded systems.● Meets IEC 61481 (excludes PC44K).

  • Radiating Loops

    Schwarzbeck Mess Elektronik

    The magnetic, handheld coil was designed to generate defined magnetic field strength in the audio frequency range up to 3 MHz. The main application is immunity testing against magnetic fields according to VG 95377 Part 13 and many others. Depending on the current source characteristics magnetic fields up to 400 A/m can be generated for a short time.There are further rings available on request in order to provide a certain scaling between coil current and magnetic field strength (e.g. 1 Amp coil current = 10 A/m field strength).

  • Test Compliance

    MX CTS Series - AMETEK Programmable Power, Inc.

    A growing number of electronic products manufactured today have to meet international regulatory requirements for emissions and immunity. This is particularly true for products sold in the European community as well as a growing list of countries in the Far East. The California Instruments MXCTS System provides a cost-effective test solution aimed at verifying higher power product compliance to a number of AC and DC related harmonized test standards. The MXCTS system offers many of the same features and capabilities of the California Instruments CTS Series product line already in use at many EMC labs around the world.

  • NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle

    865682-01 - NI

    NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle - The USB Temperature Measurement Bundle with NI-9213, cDAQ-9171, and cRIO-9940 includes the NI-9213 C Series Temperature Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9213 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels. Additionally, the NI-9213 features anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-01 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-02 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    781210-01 - NI

    Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.

  • TEM Cells

    EMCTEST

    Transverse Electro Magnetic (TEM) cell or Crawford cell (named after its inventor) is used to generate accurate electromagnetic waves over a wide frequency range: DC (0 Hz) to GHz., EM waves generated in the cell propagate in transverse mode and have the same characteristics as a plane wave. It can be used to calibrate E-field broadband probes for testing radiated E-field immunity as well as for measuring radiated emission from a product with a spectrum analyzer/EMI receiver.TEM cell generates a consistent electromagnetic field for testing small RF devices such as wireless pagers, receivers, portable phones, etc.

  • High Voltage Op Amplifiers ≥12V

    Analog Devices Inc.

    High supply voltage op amps are used in systems that demand the widest dynamic range with the best signal-to-noise ratio. Engineers turn to Analog Devices for high voltage amplifiers that deliver industry-leading performance. Increasingly, new high voltage amplifiers also offer features to improve system performance, cost, and robustness while easing the complexity of system design. New features include integrated input overvoltage protection (OVP), on-chip electromagnetic interference (EMI) filtering, higher electrostatic discharge (ESD) immunity, and greater resistance to latch-up in both powered and unpowered operations.

  • Test Compliance

    CTS Series 3.2 - AMETEK Programmable Power, Inc.

    The CTS Series is a complete, turn-key compliance test system for EN IEC 1000-3-2 (Harmonics) Including A14, EN IEC 1000-3-3 (Flicker) and various EN IEC 1000-4 AC immunity tests. Consisting of an AC power source, a power analysis conditioning system (PACS) and a PC based data acquisition system, the CTS provides a complete turn-key solution for IEC testing. The Windows™ based CTS software performs the IEC tests and generates detailed test reports. Comprehensive data files are stored on disk to allow post test analysis.

  • Two Axis Differential Interferometer

    10721A - Keysight Technologies

    The Keysight 10721A Two Axis Differential Interferometer, when used in multiple axis applications, simultaneously makes two differential measurements linear and angular (yaw) displacement. Both measurements reference external mirror mounted to an object such as a column or inspection tool. The 10721A provides high immunity to unwanted interferometer displacement, such as thermal expansion. It is a modular, compact design with monolithic optics for maximized mechanical stability. Use of a small 3 mm beam helps decrease Abb offset error. The 10721A is similar to the 10719A Single Axis Differential Interferometer, except that it provides an additional measurement axis.

  • TWTs - Traveling Wave Tubes

    Insight Product Company

    Travelling wave tubes remains a valuable type of amplifier for high output power in the microwave range. Its main advantages are of high output power, big bandwidth-duration and reliability. Insight Product Co. offers TWT packaged tubes providing output power from tens to several hundred watt in a continuous mode and to 1.5-2.0 kw in a pulse mode, and frequency bandwidth of 1.5 octaves. TWT applications include satelite communications (transponders) both on land and on satelite installations, radio relay communication lines, electromagnetic compatability (EMC) testing industry for immunity testing of electronic devices, and radars (maritime, weather, airplanes, land).

  • Traveling Wave Tube Test System

    Yelo Ltd.

    Yelo has a wealth of experience in developing and customizing test systems for the Travelling Wave Tube (TWT) market. TWT testers feature specialized power supplies, measurement equipment, and comprehensive control and safety systems.A rugged PLC is used to control all voltages and perform all monitoring functions. User interface and datalogging functions are provided by a supervisory PC that is electrically isolated from the PLC. Power Supplies are solid state with optical fibre barriers to ensure that all control/monitoring is carried out at safe voltages, and with maximum noise immunity. All safety interlocks are hardwired, and the testers are equipped with emergency shutdown features for added security.

  • Vantage PRO2 Davis

    6152 & 6152C - AYA-Instruments

    *Refresh Rate – A packet of data is sent from the outdoor transmitter to the receiver every 2 1/2 seconds! This means when you look out the window and see the wind blowing, the weather station will reflect it almost immediately.*Transmission Distance (wireless models) – The first in its consumer price range to use frequency hopping spread spectrum radio technology, the Vantage Pro2 can transmit and receive data up to 1000′ (300 m) line of sight. This is a much greater distance than most other weather stations. This technology also provides improved reception through multiple walls and greater immunity from RF interference.

  • One Axis Differential Interferometer

    10719A - Keysight Technologies

    The Keysight 10719A One Axis Differential Interferometer makes either a differential linear or angular measurement for use in single and multiple axis applications. The linear measurement gauges the displacement between two objects, such as a stage and an optical column or inspection tool. The 10719A also measures either pitch or roll. An angle is measured when both reference and measurement beams measure to the same mirror. The 10721A provides high immunity to unwanted interferometer displacement, such as thermal expansion. It is a modular, compact design with monolithic optics for maximized mechanical stability. Use of a small 3 mm beam helps decrease Abb offset error.

Get Help