Showing results: 451 - 465 of 1120 items found.
-
Panasonic Industrial Devices Sales Company of America
As a worldwide leader in Capacitor products, Panasonic provides a vast selection of Surface Mount Type Aluminum Electrolytic Capacitors featuring high reliability, long life, low impedance and high ripple current. With 30 Series to choose from, there's a Panasonic SMT Lytic Capacitor for any application.
-
QPA13 -
GigaBaudics Co.
This device has low impedance mismatch, high bandwidth, wide dynamic range and is capable of rapid state change. The QPA13 can be an attractive alternative to either the manually operated microwave attenuator switches, which are expensive and are switched very slowly, or the relay attenuators which are expensive and wear out quickly.
-
PA13 -
GigaBaudics Co.
This device has low impedance mismatch, high bandwidth, wide dynamic range and is capable of rapid state change. The PA13 can be an attractive alternative to either the manually operated microwave attenuator switches, which are expensive and are switched very slowly, or the relay attenuators which are expensive and wear out quickly.
-
A.H.Systems, Inc.
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on broadband current probes. The BCP-5xx EMC Current Probes are designed to permit field intensity meters, spectrum analyzers, and other 50W impedance instruments to measure quantitative magnitudes of current.
-
DU 800 T -
Array Solutions
The DU 800 T optimizes the performance of your antenna and transmitter or SWL receiver by providing adjustable impedance matching. The DU 800 T also measures the Power and Standing Wave Ratio (SWR), which allows you to tune the indiceted SWR to the lowestpossible ratio for the selected transmit frequency.
-
DU-3000T/DU-3000TB -
Array Solutions
The DU 3000T and DU3000TB tuners optimize the performance of your antenna and transmitter or SWL receiver by providing adjustable impedance matching. The DU-3000 series also measure the Power and Standing Wave Ratio (SWR), which allows you to tune the indicated SWR to the lowest possible value for the selected transmitfrequency.
-
CTS-10350 -
EMC Partner AG
The CTS-10350 is an impulse generator with a current wave shape 10/350 μs at the output terminals. Dual outputs enable testing of 2 terminal devices and 3 terminal devices up to class 1. The generator impedance is 1ohm in dual output mode or 0.5ohm when both outputs are connected together.
-
ZTS Technologies Co., Ltd
Fixed Terminations absorb RF & microwave energy and are commonly used as dummy loads of antenna and transmitter.They are also used as match ports in many multi-port microwave device such as circulator and directional coupler to make these ports which are not involved in the measurement be terminated in their characteristic impedance in order to ensure an accurate measurement
-
16451B -
Keysight Technologies
The 16451B is used to evaluate the dielectric constant of solid dielectric materials accurately, and complies with ASTM D150. The 16451B employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixture.
-
16380A -
Keysight Technologies
The 16380A is a standard capacitor set consisting of four precision capacitors - 1pF (16381A), 10pF (16382A) 100pF (16383A), 1000pF (16384A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
42030A -
Keysight Technologies
The 42030A is a standard resistor set consisting of nine precision resistor standards which range from 1 mΩ to 100 kΩ. These resistors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
iP60z -
iPortable
The new iP60z iPortable™ Antenna SWR Analyzer is designed for field use. This compact battery powered unit has an easy to read frequency display and measures SWR and impedance in the HF Band and VHF 6 Meter band. The SWR readings quickly show you the actual VSWR measurement and Magnitude of the impedance (Z). This is the easiest way to adjust your portable or base station antenna to be best matched for your radio.
-
HVP-40DM -
PINTEK Electronics
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
MZC-304 -
Sonel S.A.
# Measurements of impedance in a short circuit loop.- L-PE circuit,- L-N, L-L circuit,- L-PE(RCD) circuit - without tripping the circuit breaker > 30mA.# Low voltage resistance measurement:- continuity measurement - DC current +200mA with wire resistivity reset- low current resistance measurement with accoustic signalling,
-
2503AH -
Xitron Technologies Inc.
The 2503AH Analyzers measure power, voltage, and current up to 500 kHz with premier precision. Available parameters include V, A, W, Power Factor, Crest Factor, K Factor, THD, Harmonics, Phase, VA, VAR, W.Hr, Triplens, Impedance, Inrush, Mean-Peak Values, Efficiency- Loss, etc.