Showing results: 121 - 135 of 151 items found.
-
Teledyne Marine Impulse
Teledyne Impulse provides a broad array of disc drive connectors. Our connectors are RoHS compliant and are being used on most major platforms around the world. Teledyne offers its cone point technology to insure maximum connectivity performance, and high temperature plastic materials are common. Teledyne's products are designed to meet the global requirements of the computing industry. Custom design configurations are available upon request.
-
Rational Acoustics LLC
Smaart SPL offers the same complete SPL measurement toolset from Smaart v8 in a purpose-built standalone package, with an interface designed for simplicity and speed. Smaart SPL provides a powerful and full-featured solution for monitoring, metering, and logging SPL but with a format and price point more accessible to users who don’t require the real-time frequency and impulse response mode analysis capabilities of our flagship Smaart v8 software.
-
Teledyne LeCroy
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
-
T-510 -
Techno Instrumentation (India) Private Limited
Pulse Echo, Impulse current and Decay methodprovided to get the distance to almost all typesof faults.Laptop based 15 inch display with user friendlyinterface for easy operation.Online support of experts to review fault graphs.Comparison feature of any 5 graphs for reviewand analysis to get more accurate results.Velocity of propogation(VOP) control makes iteasy to precisely pre-locate faults in cables withdifferent velocity.Automatic storage of more than 10,000 faultgraphs.
-
ProDAQ 3430 -
Bustec Ltd.
The ProDAQ 3430 is a 4-channel, sigma-delta ADC function card. Every channel contains front-end conditioning circuitry followed by a sigma-delta ADC. The bit stream from every ADC is then directed to finite impulse response (FIR) decimation filters. Users can activate up to 10 stages of the FIR filters. The filtered data from the selected stages is then stored in the FIFO. The data from the FIFO easily can be moved on-the-fly to the motherboard or to the host.
-
noiseLAB -
DELTA
noiseLAB is a professional software recording and analysis package for making Type 1 Precision measurements to international standards. Precision Recorder: noiseLAB makes high quality recordings of up to 8 channels of sound. Precision Analysis of: Sound Level (Fast, Slow, Impulse, Taktmak. Custom Time Constant, Leq). Statistical Values (L1, L5, L10, L50, L90, L95, L99). Octave Spectra (1/1, 1/3, 1/6, 1/12, and 1/24th octave).....
-
RoomScope -
Faber Acoustical, LLC
RoomScope turns your iPad, iPhone, or iPod touch into a room acoustics measurement and analysis tool. With RoomScope, you can measure a room impulse response and then calculate reverberation time, early decay time, clarity, and definition, as defined in the ISO 3382 standard. RoomScope also allows you to adjust the Schroeder decay curve integration limits with the touch of your finger and plot the calculated room parameters versus whole or 1/3-octave band center frequency.
-
ToneGenerator -
NCH Software Pty Ltd
Tone Generator is a sine wave generator, frequency generator and signal generator that lets you create audio test tones, sweeps or noise waveforms using your computer or a PDA handheld. Generate sine wave, square wave, triangular waveform, saw tooth waveform, impulse, white noise and pink noise.
-
9355-1 -
Solar Electronics Company
Solar Model 9355-1 Pulse Generator is designed to provide impulse excitation by means of an injection probe placed around interconnecting cables or power wires. The unit uses a charged transmission line (50 ohms) to generate a pulse with less than 2 nanoseconds rise and fall time, and duration of approximately 30 nS, calibrated in a 50 ohm fixture to deliver up to 5 amperes at a rate of 30 p.p.s. for one minute as required by MIL-STD-461D/E, test method CS115.
-
Megger Group Ltd.
When a fault such as a short circuit or current overload is detected by a protective relay, a trip impulse is sent to the circuit breaker. The circuit breaker must function as specified and interrupt the current as soon as possible or severe damage may occur. The damage caused by a malfunctioning circuit breaker can often be catastrophic, resulting in significant damage to the electrical system.
-
MIG0603CLV1 -
EMC Partner AG
The MIG0603CLV1 is a generator for testing varistors. It has circuits with three different source impedances and up to 11 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 200A which is maintained over the entire load range.
-
KT-2000RD -
Kast Eng Co. LTD.
This equipment represents the wanted resistance value in digital figures and at the same time, is an ohmmeter which decides products to be bad in case of being out of the previously set range of H,L and to be good in case of being within the range. Moreover, because it is designed and manufactured on the basis of KAST's business experiences and know-hows accumulated through on-the-spot works for a long time, it is highly trustable, especially strong to noise and impulse that occur on the bad electric condition of on-the-spot or on the connection with any other equipments, and also is convenient for use.
-
MIG0603CLV2 -
EMC Partner AG
The MIG0603CLV2 is a generator for clamping voltage testing of varistors. It has circuits with four different source impedances and up to 15 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 500A which is maintained over the entire load range.
-
IOScope -
Faber Acoustical, LLC
With IOScope, measure loudspeaker impedance, frequency response, and sensitivity. Measure a room impulse response. Tune a large sound reinforcement system, time-align a set of surround sound speakers, or optimize your home stereo. Determine the actual cutoff frequencies of your latest speaker crossover circuit, or teach your students the fundamentals of Fourier analysis of dynamic systems.
-
Mess- & Prüfsysteme GmbH
Our high-voltage coupling capacitors are a main component of our partial discharge test stations. They serve to decouple the partial discharge impulses and act as a voltage divider, the output voltage of which is matched to our partial discharge measuring devices (with integrated voltage measurement) and peak voltage measuring devices. These high-voltage components are also available separately in their various designs, sizes, capacities and voltage ranges.