Showing results: 1726 - 1740 of 2617 items found.
-
1105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
4105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
2105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
1805 ER -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
2120 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● 0Ω adjustment.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.
-
2705 ER -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
E4990A -
Keysight Technologies
The E4990A Impedance Analyzer has a frequency range of 20 Hz to 120 MHz. The E4990A provides an industry best 0.045% (typical) basic accuracy over a wide impedance range, with a 40 V built-in DC bias source. The equivalent circuit analysis function supports seven different multi-parameter models and helps you to simulate your own equivalent parameter values of components.
-
40-592A-115 -
Pickering Interfaces Ltd.
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
1146B -
Keysight Technologies
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
300 Series Benchtop ATE -
Circuit Check, Inc.
The Circuit Check 300 Series benchtop ATE Test Platform with built-in professional fixturing solves the uncertainty of repeatable results that are common with bench testing. With the 300 Series Benchtop ATE, test procedures can become automatic, with test steps and go/ no-go limits easily programmable in common tabular form. Hand-probing is eliminated, replaced with accurate, repeatable tooling and reliable spring-loaded test probe fixturing.
-
HR8003 -
HighReach Measuring & Controlling System Co.,Ltd
HR8003 high-precision pressure water level gauge is a hydrological instrument used for water level and water temperature measurement. It is developed through years of production technology and uses advanced mixed signal processing technology to overcome the shortcomings of traditional analog circuit modules. Full-scale digital Linear correction, full temperature zone digital temperature error compensation; compensation parameters are stored in non-volatile memory.
-
DARE Electronics
DARE Electronics? solid state relays incorporate advanced microelectronic hybrid technology and are available from low level to 50 amps. Solid state relays have distinct advantages over electro-mechanical devices including: no contact bounce, arcing or flashing; immunity to contact contamination and oxide formation in dry or normally open circuits; and immunity to shock and vibration thus preventing unwanted contact closures
-
PA-699 -
PINTEK Electronics
*High sensitivity: 1mA, High frequency: 1.5MHz. They are all 10 multiple calculation. Calculation is not making mistakes.*Max measuring current: +/- 40A DC / 80 Ap-p*Max sensitivity: ≧1mA*Bandwidth: DC ~ 1.5 MHz*Rising Time: 0.23 uS*Overload indicator*1V/A, 0.1V/A 2 ranges selectors*Input power switching (priority circuit) and battery available*Dispatching design, high durability
-
DX-105 -
Dexing Magnet Tech. Co., Ltd
DX-105 Gaussmeter is a desktop gaussmeter. Which is based on the latest progress of the Hall Effect magnetic field measuring instrument.Adapt the high stability constant current source circuit technology to design and manufacture. Test probe adapts imported GaAs linear Hall-chip, the difference between any two probes is small, which can be replaced directly when it is damaged. DX-105 Gaussmeter is an ideal DC magnetic field test instrument.
-
(HAI) UL 746A -
National Technical Systems
High-Current Arc Ignition (HAI) performance is expressed as the number of arc rupture exposures (standardized to the electrode type and shape and electric circuit) that are necessary to ignite a material when they are applied at a standard rate on the surface of the material. The number of arc rupture exposures necessary to ignite a material when they are applied at a standard rate on the surface of the material. Performance Level Categories (PLC) were introduced to avoid excessive implied precision and bias.