Filter Results By:

Products

Applications

Manufacturers

Showing results: 2401 - 2415 of 2577 items found.

  • VB-8012, 2-Channel, 100 MHz Bandwidth VirtualBench All-in-One Instrument

    783555-11 - NI

    2-Channel, 100 MHz Bandwidth VirtualBench All-in-One Instrument—The VB‑8012 combines a two‑channel, 100 MHz mixed-signal oscilloscope with protocol analysis, an arbitrary waveform generator, a digital multimeter, a programmable DC power supply, and digital I/O into a single device that integrates with your PC or iPad. The VirtualBench all‑in‑one instrument is simple and convenient and results in more efficient circuit design, debugging, and validation. The included software provides an interactive way to view all your measurements on a single screen and can be updated for free with software releases over time to continually add functionality and value to your VirtualBench. VirtualBench also tightly integrates with LabVIEW software to enable programmatic control and automated test sequences.

  • 2-Module ICT System, I317x Series 6

    E9902G - Keysight Technologies

    Keysight's family of i3070 Series 6 In-Circuit Test (ICT) systems are built on a proven technology foundation, and they improve test efficiency with time-tested software, hardware, and programmability. I3070 Series 6 ICT tester supports a wide range of printed circuit board assembly (PCBA) sizes for applications including IoT and 5G, as well as automotive and energy. The i3070 features a unique design that delivers the shortest signal path between measurement circuitry and devices under test to minimize undesired effects from parasitic capacitance, improve immunity to crosstalk, and eliminate stray signal coupling effects, delivering consistent and repeatable measurements. The Series 6 is fully backward compatible with previous systems and makes highly repeatable measurements.

  • Wall-Mount Miniaturized 24V OEM Version of Rapidox 2100

    Rapidox 2100-OEM-RSB-WALL - Cambridge Sensotec Ltd

    The Rapidox 2100 OEM-RSB-WALL is a wall mount version of our miniaturised 24V OEM oxygen (O2) analyser. The compact (4.5″ x 3.0″) circuit is integrated into a neat IP65 wall mount polycarbonate box, with a clear smoked hinged lid. Behind this is a clear OLED display and menu keypad. The box is completely electrically isolated and meets all UL and IEC standards for these types of enclosures. There are cable entry glands on the base for power cables and analogue / digital / alarm leads The analyser comes with a robust cabled zirconia sensor, which is ideal for providing fast and accurate remote in-situ gas analysis over the the full oxygen range 10-20ppm to 30% O2. An optional external pressure sensor socket is included as standard.

  • VB-8012, 2-Channel, 100 MHz Bandwidth VirtualBench All-in-One Instrument

    783555-05 - NI

    2-Channel, 100 MHz Bandwidth VirtualBench All-in-One Instrument—The VB‑8012 combines a two‑channel, 100 MHz mixed-signal oscilloscope with protocol analysis, an arbitrary waveform generator, a digital multimeter, a programmable DC power supply, and digital I/O into a single device that integrates with your PC or iPad. The VirtualBench all‑in‑one instrument is simple and convenient and results in more efficient circuit design, debugging, and validation. The included software provides an interactive way to view all your measurements on a single screen and can be updated for free with software releases over time to continually add functionality and value to your VirtualBench. VirtualBench also tightly integrates with LabVIEW software to enable programmatic control and automated test sequences.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • General Purpose Low-side MOSFET Drivers

    Renesas Electronics Corp.

    Renesas' family of low-side FET drivers are very high-speed matched dual-drivers capable of delivering peak currents of 2.0 amps into highly capacitive loads and excellent at driving large capacitive loads with minimal delay and switching times. The high-speed performance is achieved by means of a proprietary "Turbo-Driver" circuit that speeds up input stages by tapping the wider voltage swing at the output. Improved speed and drive capability are enhanced by matched rise and fall delay times. These matched delays maintain the integrity of input-to-output pulse-widths to reduce timing errors and clock skew problems. This improved performance is accompanied by a 10 fold reduction in supply currents over bipolar drivers, yet without the delay time problems commonly associated with CMOS devices. Dynamic switching losses are minimized with non-overlapped drive techniques.

  • PLC's

    Datexel

    The EPL101 PLC is a circuit board OEM PLC. The EPL101 has 4 analog inputs, 7 digital inputs and 2 inputs for Encoders. It has 6 relay outputs, 5 that are rated for 5 Amps and 1 relay rated for 16 Amps. It also has an analog output 0-5 Volts. The outputs can be simple on off or P, PI,PID or PD control. The EPL101 accepts inputs from K, S, T, R, J or E type thermocouples, Pt100, Ni100 RTD'S. NTC10K thermistor inputs. The EPL101 also accepts inputs from sensors with 4-20mA, 0-20mA, 0-20mV or 0-1V signal. It also has 6 digital PNP inputs up to 1 Hz and 2 NPN inputs up to 2 K Hz.

  • Test Fixture Kits

    Equip-Test Kft.

    More then ten years of experience in special, customized engineering and manufacturing brought us to the highest level of creating reliable, flexible and robust Test Fixtures. Currently our HQ is located in Vecsés, Hungary together with our R&D. Equip Group has Test Fixture Kit manufacturing plant in Serbia, focusing on supplying competitive, high – quality and high – volume products for the global market.With more then 180 employees, Equip – Test is able to offer our customers turnkey solutions in fixturing with test program generation. No matter if you have a simple or complex, high-density PCB (Printed Circuit Boards), or if you have DUT (Device Under Test) already assembled into metal or plastic housing, we can offer you a very stable technical solution.

  • Torque Meter Bench

    Vetek Weighing AB

    BTR is a desktop torque for torque meas urements consisting of a digital indicator model DTR and a strain gauge torque extremely rugged and compact which has a precision better than 0.20%. Ideal for the calibration and the control of torque keys and to rque screwdrivers. Microprocessor indicator is fed by 4 internal batteries with an autonomy of 200 hours, with the AUTO POWER OFF function which activates if any change in the measurement is detected in an interv al of 30 minutes. The new generation electronic section consists of a particularly long-term stable analogue circuit and of a 16 bits A/D converter which ensures 65.000 internal divisions with an acquisition sp eed of 200 conversions per second. On the display there is an analogue bar for torque, that is still active, even in the programming menu.

  • Wall Scanner

    PeakTech Prüf- und Messtechnik GmbH

    The new PeakTech 3433 was specially developed for daily use in the craftsmanship, as it can be used to locate wood, metal or live lines to make sure that no damage is caused through the work of chiseling, slitting or drilling into walls. The inverted LCD display shows the distance to the material which has been found and helps the user to assess the internal condition of the wall to avoid damage to pipes or live circuits. The depth of reception of the sensor is between 20mm (wood) and 120mm (ferrous metal) depending on the material sought. In addition, an LED (green, yellow, red) indicates whether a material has been found or whether there is a live line at the current test point. The simple operation, safe application and high-quality workmanship makes this model an indispensable companion for every craftsman, handyman or installer for maintenance and all work in the building sector.

  • PXI Single 24x8 Matrix, 2 Pole Switching

    40-521-022 - Pickering Interfaces Ltd.

    Typical applications for this high density matrix include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability rutheniumelectro-plated reed relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, 7 PXI modules will form a 168x8 Matrix, a total of 1344 crosspoints in a 7-slot PXI Chassis. All 40-521 series modules are fitted with reed relays (ruthenium sputtered type), these offer very long life with good low level switching performance and excellent contact resistance stability.Spare Reed Relays are built onto the circuit board to facilitate easy maintenance with minimum downtime.

  • 47~2400MHz FTTH CATV & SAT-TV Optical Receiver

    HRS-24-H1 - Hangzhou Huatai Optic Tech. Co., Ltd.

    Huatai HRS-24-H1 product series is a kind of CATV & SAT-IF optical receiver with high-performance and high-index. 7~2400MHz operate bandwidth. Output level Vo=86dBμV ( Pin=-2dBm ), suitable for FTTH, FTTP fiber access network. It is a low power consumption, high performance and excellent cost performance CATV & DBS network ONU(Optical network unit). This series product adopts high sensitivity receiving tube and special low noise matching circuit. Under 3.8% modulation, when transmitting in full channels and with receiving power of –8dBm, the CNR can still reach high index of 48dB and low inter modulation index. If adopting HRS-24-H1, it is only need very low optical power to reach 48dB CNR required by the user.

  • Active Loop Antenna

    AL-130R - Com-Power Corporation

    Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.

  • Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel

    40-201-004 - Pickering Interfaces Ltd.

    This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel

    40-201-008 - Pickering Interfaces Ltd.

    This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

Get Help