Filter Results By:

Products

Applications

Manufacturers

Inductance

emf generated to oppose a given change in current. http://hyperphysics.phy-astr.gsu.edu/hbase/electric/induct.html

See Also: Inductor, EMF, Current


Showing results: 106 - 120 of 144 items found.

  • Flexible Pitch GND Fixture Clamps

    GF-A - High Power Pulse Instruments GmbH

    *Compatible with GGB picoprobe model 10 replacement probe tips*<1 ns rise time (200 ps possible with 5 mm GND wire length)*Custom selectable GND wire length 5-15 mm*Gold-coated spring-steel clamp with micro-machined groove for locking of the clamps on the probe tip*High conductivity and low inductance copper HF litz wire with 200 x Ø 0.02 mm strands*Easy to use clamping*Tungsten carbide probe needle with 1 inch length, 15° taper and 7.5 µm tip radius

  • MP CI set

    Langer EMV-Technik GmbH

    The MP CI set up to measure coupling impedance is used to determine EMC characteristics of connectors and cables. The coupling inductivity defines the coupling inductance of external disturbance on the shield or on the ground with the desired signals. If the coupling inductivity is considered in the construction set-up and the pin or wire assignment of connectors or cables, then the connectors or cables will be more interference-resistant. The MP CI set-up for measuring coupling impedance can be used for following measurements at connectors or cables: 1. measurement of a single signal (common mode) 2. measurement of a symmetrical signal (common mode) 3. measurement of a symmetrical signal (differential mode)

  • Impedance Standards and Calibrators

    MEATEST, s.r.o.

    Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.

  • Autocompute LCR-Q Meter

    Model 4910 - Aplab Limited

    Aplab Model 4910 is a microprocessor based digital Autocompute LCR-Q Meter that meets today’s laboratory requirements, in the production line and the quality assurance area. It features fully autoranging and automatic operation over a wide range of measurements. Model 4910 measures inductance, capacitance, resistance and quality factor to a basic accuracy of ±0.25% of the reading for values upto 2000H, 2000μF, 2M ohm and Q factor upto 99 respectively. Measurements can be made at a frequency of 100Hz or 1KHz as required and either the series equivalent or parallel equivalent component values can be displayed.

  • Tester Electrical Interfaces

    inTEST Corporation

    The primary element of the tester electrical interface is the Probe Pin Ring (PPR). Sometimes referred to as a ‘tower,’ this array of spring-loaded probes can be arranged to provide a controlled impedance path, a low leakage connection, a low inductance arrangement for high currents, or just about any connection characteristic you require. inTEST EMS provides electrical interfaces in various OEM-supported designs, inTEST standards, and custom configurations.

  • PXI Digital Multimeter

    NI

    PXI Digital Multimeters, or DMMs, feature AC/DC voltage, AC/DC current, 2- or 4-wire resistance, and frequency/period measurements, as well as diode tests. You can also choose a PXI DMM with an isolated, high-voltage digitizer that can acquire waveforms at sample rates up to 1.8 MS/s at full input range, up to 3 A or 1,000 V. Additionally, you can choose a PXI DMM that can perform basic inductance and capacitance measurements.

  • COMPUTERIZED LCRTZ TEST SYSTEM (Automatic Transformer Test System)

    CVCT-S20 - Vasavi Electronics

    Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.Test Parameters :-> Inductance-> Capacitance-> AC Resistance, -> DC Resistance, -> Impedance, -> Leakage Inductance,-> Transformation Ratio & Winding PolaritySPECIFICATIONS :Measurement Frequencies : 50 Hz, 100 Hz, 500 Hz, 800 Hz; 1 KHz, 2 KHz, 5 KHz, 10 KHz. Measurement Voltage: 0.1 V – 1.0 V RMS adjustable under program control.

  • HV AC Voltage Test Systems

    Fivestar HV Testing Equipment Co., Ltd.

    FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.

  • Handheld LCR Meter

    Smart Tweezers® - Siborg Systems Inc

    Smart Tweezers® are a hand held LCR meter that provides users with a simplified method of identifying and evaluation Surface Mount Devices and troubleshooting complex electronic systems. The unique deign combines a set of precision gold-plated tweezers and a powerful, yet small, digital LCR-meter in a lightweight device. Powered by a Li-Ion battery, Smart Tweezers® can identify the type of component and measure for Inductance, Resistance, Capacitance and ESR values with no set-up.

  • Digital and Analog Test Sets

    In-Phase Technologies, Inc.

    Our analog and digital automated test system experience covers a wide variety of applicationsfrom multiple path resistance, capacitance, and inductance testing using various Interface Test Adapters (ITA)to inter-connect multiple customer units under test (UUT). Other systems have included: equipment to monitor and record telemetry, digital data streams, and systems that evaluate packet data using a variety of VME, VXI, PXI, and LXI equipment.

  • 48 Ω HMM Pulse Force Probe

    PHD-HMM-48-1 - High Power Pulse Instruments GmbH

    *High current wafer-level and package-level 98 Ω HMM probing with grounded DUT*Built-in high surge 48 Ω pulse reflection suppression resistor up to 80 A peak*Fast rise time < 0.5 ns due to low inductance GND loop*Variable pitch from 50 µm to 5 mm*Tungsten replacement probe tips*SMA pulse force pigtail*Compatible to PHD-3001A interface*High reliability

  • Grypper G80 / G80 LIF

    Ironwood Electronics

    *Package-size PCB footprint: Since the PCB footprint of G80 is identical to the package, only one PCB design is required, enabling a seamless transition from test and validation through production and reducing overall cost of test*Low insertion force: Unique contact design reduces the insertion force required to insert and retain higher-ball-count packages safely and securely within the test socket*No lid required: The package snaps directly without a lid, enabling easy probing, scoping and troubleshooting the topside of the device*Excellent signal performance: A short signal path achieves low inductance and low insertion loss, providing a nearly invisible electrical connection

  • Single Phase Impulse Winding Tester 3 kV

    SME1203 - Scientific Mes-Technik Private Ltd

    Single Phase , 3 kV Impulse winding testing Low inductance impulse test: down to 10 μH Low energy test without damaging the coil Fast detection of winding insulation at a speed of 5.5 Meas/sec 4 kinds of waveform comparison methods Up to 40 MSPS sampling rate 320×240 dot-matrix graphic LCD display Multi-trigger mode programmableVoltage, Time and Frequency measuring functions Direct display of comparison result

  • Reactor Loss Measurement Systems

    Measurements International Ltd.

    The Shunt Reactor Loss Measurement System is a microprocessor controlled, metrology based, high voltage Capacitance, Inductance and Reactor Loss Measurement bridge which is based on the two stage- compensated current transformer. The 7010C bridge can be ordered by itself or it can be ordered with high voltage capacitors up to 800 kV line to ground and two-stage-compensated current transformers up to 4000A. the system is fully automatic displaying the rms voltage at the top of the capacitor, the reactor current and the reactor losses.

  • Connector Test

    Applied Relay Testing Ltd.

    A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.

Get Help