Filter Results By:
Products
Applications
Manufacturers
- Valhalla Scientific Inc.
product
Programmable Micro-Ohmmeter
4300C
The 4300C is the perfect instrument for tackling ultra-low resistance testing requirements associated with motors, transformers, fuses, connectors, breakers, bonding/weld resistance, and many other applications. The 4300C Digital Micro-Ohmmeter measures a variety of low-resistance devices ranging in value from 100nΩ to 20kΩ. The flexible measurement format of the 4300C provides six ranges of user selectable test current (from 0.1mA to 10A) and three voltage sensitivity settings (20mV, 200mV, and 2V).
-
product
VXI 12-Channel Digital-to-Analog
65DA2-55
NAI’s 65DA2-55 is a 12-channel Digital-to-Analog Instrument on a VXI board. This single-slot, message-based board provides twelve independent, single-ended, 16-bit, Digital-to-Analog (D/A) channels.
-
product
PXI Digital Test Instrument
PXIe-6943
Conduct pattern-based digital tests incorporating the latest parallel, digital, serial, and bus protocols with the PXIe-6943 digital test instrument.This instrument is TPS-compatible with the legacy VXI digital test instrument from Astronics as well as other instrument vendors.
-
product
VXI Digital Test Instrument
T940 Series
The T940 Series for the VXIbus provides the basis for a complete state-of-the-art digital solution at the subsystem level. The T940 is the solution for both legacy digital replacement and new test stations to be built for digital test including aircraft/ avionics, weapons systems, spacecraft, semiconductors and medical devices.
-
product
Test Instruments
Test instrumentation from COTS to custom, including VXI, PXI and LXI-based platforms.
-
product
Semiconductor Testers
Our integrated team of semiconductor test innovators delivers a complete system tailored to achieve your specific objectives, incorporating:Test strategyHardware designSoftware development and integrationManufacturingInstallationProgram managementOngoing support
-
product
Digital Test Instruments
Conduct pattern-based digital tests incorporating the latest parallel, digital, serial, and bus protocols with the PXIe-6943 digital test instrument.
-
product
Bi-Directional Differential-TTL I/O PXI Card
GX5642
The GX5642 is a 3U PXI instrument card that can be used for general data acquisition, process control, Automatic Test Equipment (ATE), Functional Test, and factory automation applications. The GX5642 consists of 64 bi-directional TTL-to-differential LVDS I/O channels. Each channel has two ports (TTL and LVDS) and can be individually set to operate in either conversion or static I/O modes.
-
product
Spectroscopy Card
microDXP
The microDXP is a complete, low power compact digital spectroscopy card design for a wide range of handheld, benchtop and other embedded applications, lowering cost and speeding time-to-market.
-
product
Instrument Transformer
Our company has achieved a reputed niche in international market by manufacturing and exporting a great range of Instrument Transformer. Widely used in electrical, power generation and engineering sector for transforming voltage or current level, this equipment is in accordance with industry standards. Manufactured using excellent grade raw materials sourced from reputed vendor, Instrument Transformer is offered to clients in different technical specifications. We stringently test this instrument on varied standard parameters.
-
product
Instrument Transformer Comparator
PMT20010
Power Measurement Technologies Inc.
The PMT20010 Comparator is an automatically balancing bridge that measures the accuracy of instrumentation potential and current transformers.
-
product
Micro and Milliohmmeter
AD-7110
The instrument AD-7110 is designed to measure, with high accuracy, resistance conductive elements of power devices: motor windings, transformer windings, conductor rails, inspecting the electrical conductivity of screw connections, crimp, welded state of the contacts of switches and relays current up to 100 A .
-
product
Micro and Milliohmmeter
AD-7010
AD-7010 instrument is designed to measure, with high accuracy, the resistance of conductive elements power equipment: motor windings, transformer windings, conductor rails, inspecting the electrical conductivity of bolted joints, crimped, welded, the contacts of switches and relays.
-
product
Peripheral Level Transformer
The Peripheral Level Transformer (PLT) is an adapter module that increases the voltage of the analog inputs&outputs for easy communication with external devices. It is connected between the instrument and the periphery.
-
product
Standard CT
6300A
The Model 2509 Instrument Current Transformer is a 6300 A ampere CT designed for precision measurement of AC current or for Instrument Current Transformer calibration applications. The CT can be installed on a bus bar or it can be used with a primary conductor consisting of number of turns. The 6300 CT is designed with a tapped primary & a tapped secondary winding, thus providing a large number of ratios over a range of 5 to 6300 amperes.
-
product
Tap Changer Analyzers & Winding Ohmmeters
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
product
TD Guard
TD Guard Intelligent Sensor is an on-line CONTINUOUS Capacitance and tan-δ monitoring system for transformer bushings. TD Guard Intelligent Sensor is the first and only instrument on the market providing absolute Tan-δ measurement in on-line permanent monitoring of transformer bushings, granting the best level of diagnostic leverage and reliability. Sensitivity better than 10-4.
-
product
Test Set For Instrument Transformer
This modern Test Set For Instrument Transformer is used for measuring relative errors of Instrument Voltage and Current Transformers. This is developed for reading out the unbalance of any bridge circuit. It also calculates the burden associated to the test sample. In addition to this, it further converts it to ratio and phase error values for presenting them on a LCD screen. With high-tech microprocessor controller, it ensures to provide quick and correct measurements.
-
product
Test Switches
Series FT
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.
-
product
Transformer Test Equipment
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
product
Transformer Winding Resistance Meters
RMO TT Series
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
product
Transformer Winding Resistance Meters
Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
product
Transformer Winding Resistance Meters
RMO TW Series
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
product
VLF/DC Hipots
HVA28
The HVA28 is the smallest, lightest VLF/DC test instrument on the market. It is about as small as you can make it! Do not let its compact size lead you to believe this unit is lacking in power. The instrument can test up to 100,000ft/30kms of cable (at reduced voltage and frequency). In addition to cables, this unit can test vacuum bottles, transformers, motors / generators, cable sheath/shields, etc.
-
product
Precision LCR Meter (20Hz to 1MHz)
ST2827
ST2827 series precision LCR meter has multiple functions and higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. ST2827 series is easy to operate with a 4.3-inch LCD screen as well as English operation interfaces. Integrated transformer test function greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.
-
product
Standard Tap Position Indicator
NMC,s Tap Position Indicator is a Microprocessor based specially designed instrument used to indicate the Tap Position of the Power Transformer with On Load Tap Changer.
-
product
Digital Tap Position Indicator With Voltage &Counter Display
NMC''s latest offering digital tap position indicator with voltage and counter display, type: TX-204, is a fully micro controller based instrument used to indicate the tap position of the power transformer also indicating the voltage and counter indications simultaneously at a same time.
-
product
Low-Voltage Arrester Analyzer
Weshine Electric Manufacturing Co., Ltd
1. This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.
-
product
Transformer Capacity Load No-load Tester
HTRS-V / 261
Wuhan Huatian Electric Power Automation Co., Ltd.
High precision instrument used in transformer capacity, no-load, load and other characteristic parameters measurement.
-
product
SAE AS5643 Mil-FireWire PXI Express Test & Simulation Instrument
HSSUB-6120
Avionics Interface Technologies
Highest density capability available in an AS5643 3U PXI Express, single slot instrument - Four (4) FireWire nodes, each with three (3) ports - Apps provide high-level (AS5643) and low-level (1394) access, while accommodating end-user customization - S100, S200, S400, S800 transfer rates - Support all Nodes operating concurrently at 800 Mbps - Independent transformer coupling for each port - Eight (8) standard PXI backplane triggers - Industry standard Texas Instruments IEEE 1394b Chipset - ANSI C (typical), C++/C#/LabVIEW
-
product
10A DIGITAL MICRO-OHMMETER
MPK-2000e
The MPK-2000e digital very low resistance ohmmeter is a portable, microprocessor controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10A. It uses the Kelvin-type, four-terminals measurement principle, thus eliminating errors caused by lead and contact resistances.