Showing results: 136 - 150 of 427 items found.
-
TH9520A -
Changzhou Tonghui Electronic Co., Ltd.
■ Six-in-one comprehensive analysis: High-power AC withstand voltage analysis DC voltage analysis Insulation resistance analysis Turn-to-turn insulation analysis DC low resistance analysis Inductance test analysis (option) ■ High-resolution: 7-inch 800 × 480 dots, TFT-LCD display
-
AD-2025 -
ADEX Urzadzenia Pomiarowe
Measuring voltage control during measurement, Insulation measurement up to 400 G W. Elimination of trough resistance insulation ? 3 connectors measurement method, Autoranging, Auto-Discharge facility safely discharges the connected circuit after a test, 5 minutes, 1 minute at will shorter measurement,
-
AD-2050 -
ADEX Urzadzenia Pomiarowe
Measuring voltage control during measurement, Insulation measurement up to 400 G W. Elimination of trough resistance insulation. 3 connectors measurement method, Autoranging, Auto-Discharge facility safely discharges the connected circuit after a test, 5 minutes, 1 minute at will shorter measurement,
-
Electro Mechanical Enterprises
Partial discharge instruments have two modes of Wide Band and Low Frequency. You can use it for Partial Discharge tests of High-Voltage Equipment, Insulation Materials, High-Frequency Equipment, and Power Semiconductor devices. Partial discharge Measuring Equipment can easily realize the test of Partial discharge on print-circuit boards, connectors, semiconductors, small motors and other insulation materials, to make a judgment on good / bad of them
-
HVST -
Test Electronics
The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. This voltage is displayed on an oscilloscope and recorded on the Pass/ Fail LED latch monitor. This voltage will be accurate despite the impedance of the winding being tested. The insulation system can be tested way above the operating voltage because of the brief duration of the applied voltage test pulse. This allows faults to be detected long before they become apparent at operating conditions.
-
ETL-8 -
Kharkovenergopribor Ltd.
Van-based cable test and fault location system ETL-8 is used for testing cable insulation and locating cable faults using a variety of methods.
-
Tinsley Precision Instruments
A range of units to cover the requirements of development laboratories and calibration and test departments. High resistance instruments provide reliable calibration of insulation testers.
-
19035 -
Chroma ATE Inc.
The quality verification tests for wound components consist mainly of AC/DC Hipot tests and insulation resistance (IR) tests. The Chroma 19035 wound component EST scanner series perform safety tests for motor, transformer, and heater related wound products.
-
2803 IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV) -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.● Built-in carry case and test leads in separate pouch.
-
2804 IN (Ranges: 1kV, 2.5kV, 5kV, 10kV) -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.● Built-in carry case and test leads in separate pouch.
-
Shanghai Launch Electric Co., Ltd.
The cascaded DC high voltage generator is mainly used to detect the characteristic of all kinds of insulation materials under high voltage, the characteristic of the DC discharge of large gap, and the insulation chearacteristic of test samples iwth large capacitance like power cable, power capacitor, generator sets, etc.
-
Shanghai Guantu Technology Co., Ltd.
AC withstand voltage test is an effective and direct method to identify the insulation strength of electrical equipment. During the operation of power equipment, the insulation will gradually deteriorate under the action of electric field, temperature and mechanical vibration for a long time, including overall deterioration and partial deterioration, forming problems. question.
-
PG 01-2000 -
Schlöder GmbH
The test generator PG 01-2000 is suitable for insulation test and testing of the impulse withstand voltage of electrical and electronic electricity meters. The generator produce a standard pulse voltage waveform with 0,1 / 2000 μs.
-
MI-20KVe -
MEGABRAS srl
The MI-20KVe High-Voltage Megohmmeter is a truly portable device that allows the measurement of insulation resistances using test voltages up to 20 kV. It employs a state-of-the-art technology for the safe measurements of insulation resistances up to 4.000.000 MΩ with four test voltages: 5 kV - 10 kV - 15 kV and 20 kV. Readings are performed through an easy-to-read analogue indicator, having a broad scale.
-
1651 IN -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● ACV auto-detection function on 3 insulation ranges (250/500/1000V) and low Ω ragne before pressing the TEST button.● 68 x 34mm large LCD display.● 3½ digital LCD (2000 counts) a LCD indicated instrument for insulation(MΩ), continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● Auto ranging.● Auto power off function.● Auto data hold function.● Rel function (ohm only)● Continuity buzzer.● External AC voltage warning.● Automatic circuit discharge.● BS 16th edition.