Filter Results By:

Products

Applications

Manufacturers

Insulation Test

Check of a materials ability to prevent or reduce transmission.

See Also: Impulse Winding Testers


Showing results: 211 - 225 of 448 items found.

  • Capacitor Leakage Current/IR Meter

    TH2689 - Changzhou Tonghui Electronic Co., Ltd.

    TH2689/TH2689A is a rapid and precise capacitance leakage current insulation resistance tester. The max. test speed of 18 times/second, good performance and the suitable price provide the user an optimal choice.

  • Impulse Winding Tester

    TH2882AS-5 - Changzhou Tonghui Electronic Co., Ltd.

    Due to the influence of coil wire material, magnetic material, framework and manufacture technics etc., coil products (such as transformers, motors, etc.) may have defects of low insulation between coil layers, circles and leads. TH2882A series impulse winding tester, adopting high-speed sampling technique, is a new generation analysis test instrument for insulation performance of coil products.

  • Impulse Winding Tester

    TH2882A-3 - Changzhou Tonghui Electronic Co., Ltd.

    Due to the influence of coil wire material, magnetic material, framework and manufacture technics etc., coil products (such as transformers, motors, etc.) may have defects of low insulation between coil layers, circles and leads. TH2882A series impulse winding tester, adopting high-speed sampling technique, is a new generation analysis test instrument for insulation performance of coil products.

  • Impulse Winding Tester

    TH2882A-5 - Changzhou Tonghui Electronic Co., Ltd.

    Due to the influence of coil wire material, magnetic material, framework and manufacture technics etc., coil products (such as transformers, motors, etc.) may have defects of low insulation between coil layers, circles and leads. TH2882A series impulse winding tester, adopting high-speed sampling technique, is a new generation analysis test instrument for insulation performance of coil products.

  • Insulation and Continuity Tester

    MIT2500 - Megger Group Ltd.

    The MIT2500 insulation and continuity tester has been designed for motor and cable testing, specialist applications and electrical testing applications, where operation voltages exceed 1000 V and higher insulation test voltages are needed. The MIT2500 offers both fixed range voltages of 50 V, 100V, 250 V, 500 V, 1000 V and 2500 V, as well as a variable range that allows any voltage between 50 V and 2500 V to be "dialled in". This is supported by the new test voltage feedback control, which maintains the output test voltage to within 2% of the selected range, even when under test.

  • Insulation & Multifunction Tester (LCD Display)

    2788 MF - Standard Electric Works Co., Ltd

    ● Auto-range microprocessor-controlled.● Insulation test voltages : 250V, 500V, 1000V.● Mov / protection devices test.● Gas Arrester function.● Automatic voltmeter AC/DC at Start/Reset.● Test ON-OFF.● Battery test.● Safety voltmeter before each test.● Auto-discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter AC/DC.● Ener-Save™.

  • Climatic Chamber

    Wewon Environmental Chambers Co, Ltd.

    Climatic chamber is designed to do high temperature & high humidity, high and low temperature, or temperature cycling test, Climatic chamber mainly used for quality checking and assessing their quality reliability and life test. ● The climatic chamber simulate a full range of temperature testing and humidity testing conditions.These chambers are designed for ease-of-use, reliability and performance and include many user-friendly features standard with your purchase for the best value in the industry. ● Climatic test chambers are able to provide rapid product temperature change rates and use varying levels of relative humidity to locate design problems prior to shipping your products, improving product quality and reliability. climatic chamber For conditioning of samples prior to testing. Climatic chamber also can be used for a variety of materials of high – low temperature alternating test. The test temperature, humidity, time can be programmed. Provides conditions of temperature form -70 degree to +150 degree and of humidity from 20% to 98%. ● This type climatic chamber use 16bit Industry-grade PLC, programmable controller to control the test temperature test, and recycle time, more excellent anti jamming, high reliability of the data. ● TEMI880 large color LCD touched screen temperature & humidity controller. Real-time display program running time, the number of segment, the remaining time, repeat frequency,can display experimental data, including the pre-set segment time, heating status, calendar time, etc; climatic chamber directly digital display. ● Climatic chambers apply controllable silicon step-less adjusting technology to adjust temperature and humidity test continuously and precisely, and without over heated as the PID adjusting function. ● The thermal insulation material between outside and inside for climatic chamber is high-quality ultra-fine glass fiber insulation cotton, good thermal insulation effectivity. Thermal insulation layer composed of flame fire PU + glass wool insulation (insulation thickness 10.0 cm)

  • Insulation Resistance Tester

    UDH-50-1-T - UDEYRAJ ELECTRICALS PRIVATE LIMITED

    utomatic-microcontroller operated• Standard test voltages-0.5kV, 1kV, 2.5kV, 5kV • Resistance range to 1TΩ • Continuous digital display on LCM• Test modes: Insulation resistance,PI (Polarization Index)AR (Dielectric Absorption Ratio)(PI and AR automatically calculated)

  • Partial Discharge Test System

    TPP - Mess- & Prüfsysteme GmbH

    The Partial Discharge Test System type TPP is used for non-destructive insulation and quality testing of electrical components (for example according VDE 0110-1, EN 50178, IEC 60270 and IEC 60060).

  • Automatic Production Tester for Electric Motor Stators

    MTC 3 - Whitelegg Machines Ltd

    The fully automatic MTC3 stator testers test your windings reliably and quickly for possible insulation faults via our patented surge voltage test.After connecting the test object completely the test is performed with an automatic switching of the connections and the test methods. The MTC3 evaluates each test step. At the end of the complete test process it provides a clear and reproducible GO or NO GO-statement.

  • Analogue (1kV below) Insulation Tester

    2132 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test. ● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • Analogue (1kV below) Insulation Tester

    1832 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • Insulation Tester

    1kV Megohmmeter - Greenlee Tools

    *Calculations (automatic)*Potential Index and Dielectric Absorption Ratios*Tests Continuity, Resistance and Frequency Measurements*Programmable Alarms*Insulation Test, Resistance, Continuity*Hazardous Voltage Alert (Icon) if voltage is >70 volts 5.) On Board Timer, +1/- 1 sec

  • Insulation Tester

    Calibrated 1kV Megohmmeter - Greenlee Tools

    *Calculations (automatic)*Potential Index and Dielectric Absorption Ratios*Tests Continuity, Resistance and Frequency Measurements*Programmable Alarms*Insulation Test, Resistance, Continuity*Hazardous Voltage Alert (Icon) if voltage is >70 volts 5.) On Board Timer, +1/- 1 sec.

  • Transformer Resistance Testing

    Weshine Electric Manufacturing Co., Ltd

    Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the WESHINE Transformer Ohmmeter (VS-3110 series) of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.