  • Bench Digital Multimeter, Calibrated D & U, 1 kV, 10 A, 3.8 Digit

    72-1015 CAL DU - Tenma

    The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.

  • Safety Compliance Test System

    EN 60601 - LXinstruments GmbH

    Test system for electrical safety compliance testing of medical products in accordance with EN 60601-1, 3rd edition.The system is equipped with three test fixtures which are connected in parallel order to reduce the number of setup tasks for different variants in the course of day-to-day manufacturing processes. Its purpose is to test medical products, e. g. patient monitors, which are employed at hospitals to monitor heartbeat and oxygen saturation.Based on the integrated electrical safety tester by Associated Research, in combination with an AC power source and a switching matrix, it is possible to fully automate tests like for instance AC/DC high-voltage tests, insulation resistance measurements, earth connection tests and leakage current measurements.The required occupational safety is provided by a high-voltage safety hood in accordance with EN 501191. The entire safety technology, as well as the control PC, is mounted in an aluminum-profile cart.

  • Short Circuit Locator for Power Cables

    A910 - AGM Elettronica

    The A910 is a short circuit locator designed for fault location in power cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A910 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 5mohm (approximately 90 m of 300 sqmm cable) and less than 30 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.

  • Multi-purpose Tester

    DEL-101 - Standard Electric Works Co., Ltd

    ● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.

  • Furnaces

    Instron

    These three zone resistance wire wound furnaces are of split construction to facilitate fast and easy loading of a pre-assembled specimen train. The case is constructed from stainless steel with aluminium and hardened insulation board end plates. The optional front cut-out allows the use of side-entry high-temperature extensometry. Adjustable stainless steel latches keep the furnace halves locked together during use, but are then easily opened once testing is complete. The furnace is available with optional heavy duty brackets or mountings, which attach to a wide range of testing systems. An extensive range of standard controllers is available to suit most test regimes. Custom variants can be specified should the standard range not include a suitable unit.

  • BATTERY PACK AND BMSTEST SYSTEMS

    DMC, Inc.

    DMC's Battery Pack Test Systems facilitate battery design as well as research and development for national laboratories and research institutions. They are deployed in end of line / production test stations for battery packs developed by major automotive manufacturers and their suppliers. DMC's battery pack test systems are designed to evaluate the battery as a complete system and validate a comprehensive range of battery pack functionalities, including:Power performance, Capacity, DCR / Internal ResistanceContactor and safety interlock functionsIsolation / Insulation ResistancesReporting of operating data through external communication interfaces (usually CAN)Cell VoltagesPack / Cell TemperaturesState of ChargeFaults / Diagnostic Trouble Codes (DTCs)Etc.Electrical characteristics / continuity of internal pack wiring / signalsCooling system operation

  • Elongation Tester

    SC-5 - Shanghai Dean Electrical Co., Ltd

    Executive standard: GB/T4074.3-2008/IEC60851-3; Inspection standard: JB/T4279.3-2008Used to test elongation (ductility) of copper wires covered with φ0.100-3.0 mmenamel, silk or other insulation materials and other metal wires with tensile strength ≤2000N;Application of SCM control allows for fast operation and strong anti-interference capacity;Preset elongation of samples with two-digit toggle switch and, when the preset value is reached during test, motor and counter would automatically stop action and display results;The instrument is capable of measuring elongation while also the tensile force and holding the maximum tensile force value during stretching;Clamps are designed according to characteristics of various wires to prevent samples from breaking at clamp jaws, easy to load samples and, after samples are compressed, enamel can be automatically broken;While sample is broken, movable clamp would automatically stop moving, with error between displayed and actual elongation value less than 1%;

  • Connector Test

    Applied Relay Testing Ltd.

    A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.

  • Battery Pack Rotate Test Device

    Guangdong Bell Experiment Equipment Co.,Ltd

    DGBell's Battery Pack Rotate Test Device Single storage cell safety testTest object: Battery storage pack or systemRotate the battery pack 360°around X axis with rotation speed of 6°/s; secondly rotate it 90°,180°,270°,360°,and remain for one hour after each move. Then stop and observe for 2 hours.Rotate the batter pack 360°around Y axis with rotation speed of 6°/s; secondly rotate it 90°,180°,270°,360°,and remain for one hour after each move. Then stop and observe for 2 hours.Accept standard: Battery pack or system has no electrolyte leakage, no rupture at case, no fire nor explosion. And remain the connection reliable, the structure intact, the insulation resistance value not less than 100 Omega /v.

  • Multifunction Electrical Installations Meter

    MPI-520 - Sonel S.A.

    The MPI-520 multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520 is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.Wide range of standard accessories enable to perform all necessary measurements and safety test. Highly professional portable multifunction meter with memory of measured parameters.

  • Fuel Quantity Testers

    Barfield Inc.

    Fuel capacitance systems are separated into two broad groupings, AC capacitance and DC capacitance. The source of these names derives from the type of signal processed by the fuel system amplifier. Barfield designs a universal tester for each type of system with the proper interface harnesses to access individual aircraft applications. Some of the various test and measurements include:*Insulation - Testing the wiring and probes*Fuel Tank Capacitance Measurement*Individual Probe Capacitance Measurement*Capacitance Simulation - Indicators and amplifiers*Indicators - Bench testing of remote units

  • AC Motor Tester

    AIP892X series - Qingdao AIP Intelligent Instruments Co., Ltd

    This product is suitable for electrical performance testing of all types of motors, such as home appliance motors (washing machines, air conditioners, fans, etc.), pump motors, stepper motors, etc. One-stop testing completes all set items, stable, fast, efficient and accurate, widely used by domestic and foreign enterprises.This AC motor tester test items: AC Hi-pot, insulation resistance, surge, DC winding resistance, no-load characteristics, low voltage start, locked rotor, rotation, PG characteristics.

  • *High Current Switches

    B-1002 - Ruetz Technologies GmbH

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • High Current Switches

    B-1002 - ROSS ENGINEERING CORPORATION

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • High Voltage Grounding Relays

    B-1007 - ROSS ENGINEERING CORPORATION

    Extra high voltage, low corona, grounding relays of the air insulated type.  Peak test ratings up to 300kV and 100 amps continuous.  Units can be operated either by solenoid, motor, or air cylinder, with spring or gravity return.  All models have spherical contacts.  When voltage transient limiting is required, some models have an adjustable sphere gap.  Also available are units with built-in high voltage discharge resistors with energy dissipation capabilities from 50 to 10,000 ohms.  Some units can be reduced in height if full line to ground voltage is connected to the top high voltage contact only and the other high voltage terminal is operating at, or near, ground potential.  Line to ground voltage can also be increased by adding insulation between lower high voltage contact and ground.  Normally mounted base down.  Base up mounting if specified.