Showing results: 76 - 90 of 1211 items found.
-
8010 IN -
Standard Electric Works Co., Ltd
● Microprocessor controlled.● Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V● The maximum insulation measurement range is 200G ohm @1000V.● 1mA test current on insulation test at nominal voltage.● With a hand strap for easier holding.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III 600V IEC 61557-1 IEC 61557-2 EN 61326-1
-
200M -
Laxtronics Instruments & Controls Pvt. Ltd
Digital insulation tester Model No: DIT200M is designed to carry out electrical insulation measurement in delicate or sensitive electronic sensors, transducers, modules and assemblies with test voltage from 1 to 30 Volts DC, its short circuit current is less than 100uA. The instrument can measure Resistance from 1 Meg Ohm to 1000 Meg Ohms.
-
-
-
-
NEPTUNE -
HT Italia Srl
NEPTUNE is a mix of technology including an instrument for electrical safety testing (insulation up to 1000V and continuity with 200mA), a Harmonics analyzer and a TRMS multimeter.
-
8005 IN -
Standard Electric Works Co., Ltd
● Microprocessor controlled.● Four insulation test voltages (DC) : 50V, 100V, 250V, 500V● The maximum insulation measurement range is 200G ohm @500V.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III
-
AMIC-2505 -
Amperis sl
Measurement of insulation resistance: 500,1000 and 2500V (2TΩ) ; 2 and 3 wire method ; Measurement of DC and AC voltages at 0...600V ; Measurement of leakage currents
-
WB2681A -
Lisun Electronics Inc.
• Insulation test voltages: DC250V、DC500V、DC1000V • Range of open-circuit voltage: ±10% rated voltage • Testing time: 3~99 seconds or controlled manually
-
DIRANA -
OMICRON electronics
DIRANA uses dielectric frequency response (DFR) analysis in order to determine the condition of high-voltage insulation systems such as those in power transformers, bushings, cables and generators.
-
TX 01 -
Chauvin Arnoux Metrix
Communicating 5-1 V Telecom Insulation and Continuity Tester2 GΩ, Test voltage: 5-1 VContinuity, Voltage, Frequency, CapacitanceDistance = f(C)Storage, Communication
-
TOS7210S -
Kikusui Electronics Corp.
The PID insulation tester (TOS7210S) is designed based on the insulation resistance tester (TOS7200) to carry out the evaluation of the PID (Potential Induced Degradation) effect of the PV module precisely and efficiently. Being equipped with the output ability of 2000 V and the ammeter with nA resolution as well as a polarity switching function, the TOS7210S is also applicable not only to the PID evaluation but also the evaluation of the insulators that requires a high sensitivity of measurement. The tester is equipped with the panel memory that is externally accessible and RS232C interface as standard; it can be flexibly compatible with the automated system.
-
Brymen Technology Corporation
Insulation Multimeter is a new category of test tool that combines a full featured True-rms DMM and a megohmme- ter. It's an integrated tool for maintaining and troubleshooting motor systems, electrical distribu- tion, and production equipment.
-
M300RT -
Rod-L Electronics
Performs DC insulation resistance test " detects up to 4000 megohms at 500 VDC " Tests in compliance with UL, VDE, IEC and MIL STD 202 test standards. IEEE-488 optional
-
Laycock Systems
Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.