Filter Results By:

Products

Applications

Manufacturers

Interfaces

connections between dissimilar environments.

See Also: Serial Interfaces, Parallel Interface, Bus Interfaces, UI, MIPI, Interface Adapters, Interconnects


Showing results: 4291 - 4305 of 5965 items found.

  • 16-Channel 250 MHz A/D with DDC, Kintex UltraScale FPGA - 6U VPX

    Model 58131 - Pentek, Inc.

    - Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Ideal radar and software radio interface solution- Supports two Xilinx Kintex UltraScale FPGAs- Sixteen 250 MHz 16-bit A/Ds- Sixteen multiband DDCs (digital downconverters)10 GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available

  • 2-Ch 500 MHz A/D with DDC & 2-Ch 800 MHz D/A with DUC, Virtex-7 FPGA - XMC

    Model 71751 - Pentek, Inc.

    - Complete radar and software radio interface solution- Supports Xilinx Virtex-7 VXT FPGAs- Two 500 MHz 12-bit A/Ds- Two multiband DDCs (digital downconverters)- Two 800 MHz 16-bit D/As- One DUC (digital upconverter)- Multiboard programmable beamformer- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multimodule synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- VITA 42.0 XMC compatible with switched fabric interfacesOptional LVDS connections to the Virtex-7 FPGA for custom I/OAlso available in 3U VPX, 3U & 6U cPCI & PCIeSupports GateXpress® FPGA-PCIe Configuration ManagerSynchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • 4-Channel 200 MHz, 16-bit A/D with Virtex-7 FPGA - 3U VPX

    Model 52760 - Pentek, Inc.

    - Complete radar and software radio interface solution- Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- Four 200 MHz 16-bit A/Ds- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- 3U VPX form factor provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • 8-Channel 250 MHz A/D with DDC, Kintex UltraScale FPGA - 6U VPX

    Model 57131 - Pentek, Inc.

    - Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Ideal radar and software radio interface solution- Supports one Xilinx Kintex UltraScale FPGAs- Eight 250 MHz 16-bit A/Ds- Eight multiband DDCs (digital downconverters)- 5 GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available

  • 4-Channel 1.25 GHz, 16-bit D/A with Virtex-6 FPGA - 3U VPX

    Model 52670 - Pentek, Inc.

    - Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Four 1.25 GHz 16-bit D/As- Four digital upconverters- Programmable output levels- 250 MHz max. output bandwidth- 2 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- Dual µSync clock/sync bus for multimodule synchronization- User-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- 3U VPX form factor provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount

  • Programmable Low-Ohm Meter

    DU5210/5211 - Delta United Instrument Co., Ltd.

    20m ~ 2Mtest range, 0.1% accuracy Provided Level and Pulse measurement modes, can be lower temperature influence in Pulse Mode Provided HI/LOW limit and BIN Sorting comparator function, to meet your needed 100 sets of memory, can be saved test parameter and comparator setting, easy to use. Auto Calibration Program Function, to easier your calibration procedure. (Specificity calibrator needed) Cover up free, system firmware upgrade can be update via RS-232, easy to maintenance High speed FADC, max. test speed up to 80 meas./sec, faster your automation equipment 240*64 Graphic LCD display, can be read the reading clearly and easier. User friendly programmable interface, easy to use Provided RS-232C and Handler combinatorial interface option, to meet your needed

  • Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel

    40-201-004 - Pickering Interfaces Ltd.

    This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel

    40-201-008 - Pickering Interfaces Ltd.

    This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Spectrographs & Monochromators

    ZOLIX

    Manual micrometer adjustable slits for precision control of incoming light. Motorized Slit and fixed slit is optional. More than 100 gratings for the best spectral range, throughput and dispersion to meet your applicationDSP controlled stepping motor scanning system provides superior precision and repeatability of wavelength positioningOptional internal shutter or six-position filter wheel for experiments requiring background removal or signal attenuationInstallation and set-up through USB 2.0 computer interfaces Stand-alone Omni Series monochromator control software for basic scanning and calibration. Also includes utilities for grating updates and communications Active X control support Visual Basic, C++ and Delphi drivers allow users to design their own acquisition programsZolixScan data acquisition software provides a simple user interface for easy data acquisition and experimental set-up

  • USB Isolators

    Analog Devices Inc.

    USB isolators protect the communication interface between the host, such as a PC, and its peripheral. Utilizing iCoupler® digital isolation technology, Analog Devices offers USB 2.0 compliant SOIC components with data rates up to 12 Mbps that provide EMC protection and safety isolation, reduce design size and time, and lower system cost. Galvanically isolated USB μModule® (micromodule) transceivers integrate the USB interface with an isolated dc-to-dc converter for up to 2.5 W of isolated power and provide ±15 kV ESD. Whether for host, hub, bus splitter, or peripheral device, these transparent USB digital isolators are easy to use—they just work—all while meeting the demanding standards required for medical and industrial applications.

  • Precision LCR Meter

    TH2816A - Changzhou Tonghui Electronic Co., Ltd.

    TH2816A is a new precision LCR meter combined with years of technical experience and newest measurement technology of instrument industry. With powerful measurement functions, high performance and low cost, TH2816A/TH2816B/TH2817A have been one of the world advanced instruments, and it provides users a super value measurement resolution and experience. The meter offers stable 6 digit resolution, wide frequency range (200kHz for TH2816A), programmable signal level (0.01V to 2.0V), up to 30 meas/sec measurement rate, 9 measurement ranges, 30Ω or 100Ω constant output impedance and friendly operation interface. TH2816Acan be used for incoming inspection of components, quality control of product line and high accuracy laboratory use. The HANDLER, GPIB, RS232C interfaces make it easy to build an automatic component test system,

  • Precision LCR Meter

    TH2817A - Changzhou Tonghui Electronic Co., Ltd.

    TH2817A is a new precision LCR meter combined with years of technical experience and newest measurement technology of instrument industry. With powerful measurement functions, high performance and low cost, TH2817A has been one of the world advanced instruments, and it provides users a super value measurement resolution and experience. The meter offers stable 6 digit resolution, wide frequency range (50Hz to 100kHz for TH2817A ), programmable signal level (0.01V to 2.0V), up to 30 meas/sec measurement rate, 9 measurement ranges, 30Ω or 100Ω constant output impedance and friendly operation interface. TH2817A can be used for incoming inspection of components, quality control of product line and high accuracy laboratory use. The HANDLER, GPIB, RS232C interfaces make it easy to build an automatic component test system,

  • Precision LCR Meter

    TH2816B - Changzhou Tonghui Electronic Co., Ltd.

    TH2816B is a new precision LCR meter combined with years of technical experience and newest measurement technology of instrument industry. With powerful measurement functions, high performance and low cost, TH2816B has been one of the world advanced instruments, and it provides users a super value measurement resolution and experience. The meter offers stable 6 digit resolution, wide frequency range ( 50Hz to 200kHz for TH2816AB), programmable signal level (0.01V to 2.0V), up to 30 meas/sec measurement rate, 9 measurement ranges, 30Ω or 100Ω constant output impedance and friendly operation interface. TH2816B can be used for incoming inspection of components, quality control of product line and high accuracy laboratory use. The HANDLER, GPIB, RS232C interfaces make it easy to build an automatic component test system,

  • Universal Cable/Harness Tester

    LX-686 - Shenzhen Lian Xin Technology Co., Ltd.

    The system provides Chinese/English free switch operation interface,.·Up to 1500Vdc/1000Vac Test Voltage ,.·256 Max. Test Points , (Max of all series).·500 Max Files Memory,support USB or PC unlimited expansion,.·Arc detection level 0-9 ,auto prompt.·Adopted high resolution colour 640*480 TFT LCD ,.·Providing Single-End ,Multi-segment ,Standard ,and Spot test of wire..·Auto Scan and Auto Pin Search ,.·The system provides advanced instant open-circuit, short-circuit, continuity test,.·Intermittent Conductance Test,.·Intermittent Open/Short Test ,.·Full Programming Sequence Test ,.·Versatile I/O Ports for application ,.·Statistics and Print Function,.·Provide REMOTE interface, communicate with PLD auto test fixture,.·Provide personalized customization according to different requirements,

  • Digital Power Meter, 30A

    66205 - Chroma Systems Solutions, Inc.

    Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface

Get Help