Filter Results By:

Products

Applications

Manufacturers

Interference

wave hitting waves.

See Also: EMI, Interference Generators, Amplitude


Showing results: 331 - 345 of 389 items found.

  • Preamplifiers

    Com-Power Corporation

    Com-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification.

  • High Voltage Op Amplifiers ≥12V

    Analog Devices Inc.

    High supply voltage op amps are used in systems that demand the widest dynamic range with the best signal-to-noise ratio. Engineers turn to Analog Devices for high voltage amplifiers that deliver industry-leading performance. Increasingly, new high voltage amplifiers also offer features to improve system performance, cost, and robustness while easing the complexity of system design. New features include integrated input overvoltage protection (OVP), on-chip electromagnetic interference (EMI) filtering, higher electrostatic discharge (ESD) immunity, and greater resistance to latch-up in both powered and unpowered operations.

  • Audio Line Drivers and Receivers

    Analog Devices Inc.

    Analog Devices audio line driver and receiver solutions feature differential-output buffer amplifiers and differential input buffer amplifiers to support a wide range of applications. By using low noise thermally matched thin film resistors and high slew rate amplifiers, these parts maintain the sonic quality of audio systems by eliminating power line hum, RF interference, voltage drops, and other externally generated noise commonly encountered with long audio cable runs. Applications involving this product portfolio include ADC drivers, high performance audio, sine/cosine encoders, and other professional and consumer uses.

  • Resonant Chopper Systems

    Electro-Optical Products Corp.

    An external clock signal, to provide an ultra stable modulating optical beam motion [sub] system. The system can be used as a "stand alone" unit, in the laboratory, or can be incorporated into a larger instrument/system. The chopper is ONE FIXED FREQUENCY, picked from the range of 5 Hz to 20 kHz. The chopper is a small size, light weigh, low cost and long life device. It requires low power drive electronics and does not radiate electromagnetic interference (EMI). It has high frequency stability and high amplitude stability. The chopper is IR, VIS and UV and high vacuum capable. Reference signal and position output available.

  • Software

    Guzik Technical Enterprises

    Besides the primary WITE32 Test Environment package at the heart of our spinstand-based test systems, Guzik offers a variety of software options to provide additional measurement accuracy and analysis. Control and Automation software enhances various electro-mechanical capabilities of the test system (such as servo accuracy), and the available suite of Analysis software tools provides deep insight into the drive component under evaluation. Adjacent Track Interference, 3D Pulse Profile, Media Scanning and Bit Error Rate are examples of some of the optional additions. Some software tools require the WDM5000 Waveform Digitizer to be part of the overall test system.

  • Wi-Fi Hound 2.4 GHz & 5 GHz RF Spectrum Analyzer

    Triplett Test Equipment & Tools

    A full-featured WiFi Troubleshooter/RF Spectrum Analyzer at an affordable price. Triplett's WiFi Hound is a 2.4 GHz/5GHz spectrum analyzer designed to help you troubleshoot and isolate problems that impact the quality of your wireless networks. With its user-friendly display, you will properly analyze the wireless environment and successfully troubleshoot: see and isolate radio interference and document the problems by creating a custom-branded, high quality, detailed, full-color report for your client with the click of a button. This perfectly portable device is the ideal solution for field techs and wireless professionals. Designed for live environments and ideal for smart homes or businesses.

  • Optical Performance Monitor

    Optoplex Corporation

    Optoplex Optical performance monitor (OPM) uses proprietary thin-film interference filter technology combined with a micro-actuator and high-speed electronics. Optical performance monitor is used to measure critical information data on optical transmission signals in DWDM networks for monitoring signal dynamics, determining system functionality, identifying performance change, and providing feedback for controlling network elements so as to optimize operational performance. In particular, Optoplex Optical performance monitor can automatically scan the C-, L- or C+L-band wavelength range and precisely measure channel wavelength and power. See the following schematic diagram for OPM working principle.

  • RF Acquisition Record and Playback Instrument

    SARP-6 - Saluki Technology Inc.

    Saluki SARP-6 RF Signal Acquisition Record and Playback Apparatus is a portable RF signal acquisition record playback equipment. It can be used to directly acquire, record, and playback RF signal from 1MHz to 6GHz. Its data recording and bandwidth playback can reach 200MHz. The SARP-6 RF Signal Acquisition Record and Playback system is composed of up and down inverter module, high-performance ADC and DAC, and large capacity solid-state FLASH or high-performance disk. It is widely used in radar, GPS, communication, telemetry, as well as many other circumstances for civil purposes when acquiring signal and recording it down.Applications: Interference Analysis/Surveillance/Spectrum Management/Satellite Communications

  • Low Voltage DC / Battery Powered High Voltage Amplifiers

    WMA-005 And WMA-005LF - Falco Systems

    The Falco Systems WMA-005 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 3mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-005LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.1mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.

  • Low Voltage DC / Battery Powered HV Amplifiers

    WMA-01 And WMA-01LF - Falco Systems

    The Falco Systems WMA-01 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 3mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-01LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.1mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.

  • Low Voltage DC / Battery Powered HV Amplifiers

    WMA-02 And WMA-02LF - Falco Systems

    The Falco Systems WMA-02 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 4mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-02LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.2mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.

  • Antenna Test Chamber for Automotive Radar

    ATS1500C - Rohde & Schwarz GmbH & Co. KG

    The R&S®ATS1500C radar test chamber is a compact antenna test range (CATR), consisting of a gold-plated parabolic reflector and a two-axis positioner for 3D movements of the radar module. Combined with the R&S®AREG800A target simulator and other Rohde & Schwarz test and measuring instruments, it can be used for a variety of applications, including antenna characterization, module calibration, RF performance validation, interference testing or in-band compliance testing. The chamber is equipped with a universal feed antenna which gives access to both polarizations in parallel. Automated temperature testing over the range of -40 to 85°C is possible with an optional enclosure.

  • Modulation Distortion Up To 70 GHz

    S930707B - Keysight Technologies

    S930707B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 70 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930707B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 8.5 GHz

    S930700B - Keysight Technologies

    S930700B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 8.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930700B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 26.5 GHz

    S930702B - Keysight Technologies

    S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

Get Help