Showing results: 16 - 30 of 704 items found.
-
VME-1182A -
Abaco Systems Inc
A multifunctional intelligent controller allows COS, SOE, pulse accumulation, debounce times and time tagging control on a per-channel basis.
-
-
783731-01 -
NI
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 … includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
781345-01 -
NI
102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4331 is a high-speed input module that provides integrated data acquisition and signal conditioning for dynamic strain, load, and pressure measurements. This module includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4331 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4331 provides remote sensing, internal bridge completion, and shunt calibration options per channel.
-
Kontron
3U/ 4HP CompactPCI remote controller for use in CompactPCI rear system slot inside a 19″ chassis, PC PCIe interface card for standard desktop PC, allows control of CompactPCI Chassis from desktop PC
-
PCI-7442/7443/7444 -
ADLINK Technology Inc.
Responding to the industry"s need for high-density digital input/output modules, the ADLINK PCI-7442/7443/7444 DIO card series delivers up to 128 opto-isolated channels for a wide range of demanding PCI-based applications. The PCI-7442/7443/7444 series comes with 64 (PCI-7442) or 128 (PCI-7443) opto-isolated digital inputs and 64 (PCI-7442) or 128 (PCI-7444) opto-isolated digital outputs. With a 1250 VRMS (excluding cables) channel-to-system isolation protection, these cards are shielded from damage caused by accidental contact with external voltage while promoting simple ground connections. All input channels are identical non-polarity with each line isolated and suited to collect digital inputs even at high-noise environments. Featuring a Change-of-State (COS) interrupt function, the PCI-7442/PCI-7443 instantly generates an interrupt request to the PCI controller when it detects a sharp change in the logical state of any of its digital inputs.
-
781337-01 -
NI
16-Bit, 8-Channel, 250 kS/s, 300 V, Ch-Ch Isolated PXI Analog Input Module—The PXIe‑4300 provides integrated data acquisition and signal conditioning for high-voltage measurements. It provides increased accuracy, simultaneous sampling, and synchronization features for scalable measurement systems. The PXIe‑4300 includes 300 Vrms channel‑to‑channel CAT II isolation and 3,300 Vrms channel‑to‑earth 5 second withstand isolation to protect users and equipment from hazardous voltages. This module offers programmable lowpass filtering, DC input coupling, and two PFI lines for digital input triggering. The included NI‑DAQmx driver simplifies hardware and configuration and measurement.
-
40-491-001 -
Pickering Interfaces Ltd.
The 40-490 Digital I/O Modules are designed for applications requiring optically isolated digital I/O, typically in industrial automation. This modules features 32 digital outputs and 16 digital inputs which may be programmed by word or individual bit. Power for the isolated section of the module is built onto the board in model 40-490-001, or this can be supplied externally in model 40-490-002.
-
40-490-002 -
Pickering Interfaces Ltd.
The 40-490 Digital I/O Modules are designed for applications requiring optically isolated digital I/O, typically in industrial automation. This modules features 32 digital outputs and 16 digital inputs which may be programmed by word or individual bit. Power for the isolated section of the module is built onto the board in model 40-490-001, or this can be supplied externally in model 40-490-002.
-
40-491-002 -
Pickering Interfaces Ltd.
The 40-490 Digital I/O Modules are designed for applications requiring optically isolated digital I/O, typically in industrial automation. This modules features 32 digital outputs and 16 digital inputs which may be programmed by word or individual bit. Power for the isolated section of the module is built onto the board in model 40-490-001, or this can be supplied externally in model 40-490-002.
-
40-490-001 -
Pickering Interfaces Ltd.
The 40-490-001 PXI module is designed for applications requiring optically isolated digital I/O, typically in industrial automation. The module features 32 digital outputs and 16 digital inputs that can be programmed by word or individual bit.
-
42-412A-024 -
Pickering Interfaces Ltd.
The 40-412A-024 (PXI) and 42-412A-024 (PXIe) are 16-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
40-412A-024 -
Pickering Interfaces Ltd.
16-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
778967-01 -
NI
64-Channel, ±30 VDC, Sink/Source Inputs, Bank-Isolated PXI Digital I/O Module—The PXI‑6511 is an industrial digital input interface, with eight banks of isolated channels. If a computer or application fault occurs, the PXI‑6511 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
778964-01 -
NI
64-Channel, ±30 VDC, 32 Sink/Source Inputs, 32 Sink Outputs, Bank-Isolated PXI Digital I/O Module—The PXI‑6515 is an industrial digital I/O interface with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PXI‑6515 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.