Filter Results By:

Products

Applications

Manufacturers

Light

Visible spectrum of electromagnetic radiation from 400nm to 700nm.


Showing results 571 - 585 of 1968 products found.

  • Omni-Station Workstation

    Omni-Station - ZOLIX

    Omni-Station includes Light Source,Spectrometer,Dark Room, Data Acquisition System,Dark Room,Optical Table,Software and accessories; Omni-Station provides spectral measurement of transmittance & reflectance of optical components on the basis of tunable monochromatic light source; The functional modular concept of Omni-Station ensure more convenient measurement units in production,R&D,inspection and related process;

  • Optical microscopy (OM)

    Materials Analysis Technology Inc.

    Optical microscopy is used to display the surface morphology of samples by 2D intensity contrast due to deflection and reflection of visible light shined on areas of interest. Its resolution is about half of the incident wavelength, which is ~0.2 μm for visible light (wavelength of 400-700 nm). Such resolution limits the maximum magnification to X1000, and thus optical microscopy provides preliminary inspection of sample surface structure.

  • Portable and Automatic Mini-Distillation Analyzer

    MINIDIS ADXpert Automatic Mini-Distillation - Grabner Instruments

    This true atmospheric distillation analyzer is extremely compact, portable and light weight and operates as a fully stand-alone unit. Designed for the quick and accurate quality control in laboratories and in the field, a distillation run on light products takes just 15 minutes and requires as little as 6 mL of sample. Because of its small size, the portable mini-distillation apparatus is the ultimate solution for places where limited or no lab-space is available.

  • Hammer Type Surface Resistance Tester

    SJC-030B - KING GLORY TECHNOLGY DONGGUAN COMPANY LTD

    1.Low battery indicator light on when battery is under 5V. 2.Digital display. 3.Multi-Functional teser measure environmeint Temperature/Humidity/Suface Resistance. Functions: Surface Resistance Meter is designed to measure the resistance of a target surface.The conductive conduit allows measurement from 10³Ω to 10¹²Ω.It is based on ASTM Standard D257 testing method.Press and hold the red button on the surface of targeted object;light on to indicate the result of resistance.High accurancy(50%).

  • Laser Photodiode Sensors

    Ophir Photonics

    Photodiode sensors have a high degree of linearity over a large range of light power levels: from fractions of a nanowatt to about 2 mW. Above that light level, corresponding to a current of about 1 mA, the sensor saturates and reads erroneously low. Therefore, most Ophir PD sensors have a built-in and removable attenuator allows measurement of up to 3 W without saturation.

  • LED Illumination Systems

    pE-100 - CoolLED Ltd.

    The pE-100 series is a mercury-free family of compact and simple to use LED illumination systems which can be configured to deliver light directly to a microscope, or via a liquid light guide or multimode fiber. Systems can be specified at any one of 20 different LED wavelengths. Operation is by a remote manual control pod with instant on/off and intensity control from 0-100%. Remote control is available via a TTL trigger.

  • LED tester

    ECOPIA

    Ecopia's LED tester is good to measure both electrical(I-V curve) and optical(Spectra, Light intensity) properties of LED chip, LED lamp, SMD type at the same time.It also makes it possible to see LED sample's construction , seeing through microscope. LED tester main body flow input current ,and emitted light from the LED sample is focused on lens of microscope.From this process, our LED tester can provide repeatable tested results and minimize error values and improve convenience of how to use.

  • Inductively Coupled Plasma Spectroscopy (ICP-OES/MS), ICP Analysis Services

    Evans Analytical Group®

    ICP-OES measures the light emitted at element-specific characteristic wavelengths from thermally excited analyte ions . This light emitted is separated and measured in a spectrometer, yielding an intensity measurement that can be converted to an elemental concentration by comparison with calibration standards. ICP-MS (ICP-Mass Spec) measures the masses of the element ions generated by the high temperature argon plasma. The ions created in the plasma are separated by their mass to charge ratios, enabling the identifcation and quantitation of unknown materials. ICP-MS offers extremely high sensitivity (i.e. low detection limits) for a wide range of elements

  • Uncooled InAsSb Photovoltaic Detector

    P13894-011MA - Hamamatsu Photonics K.K.

    Hamamatsu Photonics K.K. has developed an uncooled InAsSb (indium arsenide antimonide) photovoltaic detector that offers high-speed and high-sensitivity detection of infrared light in the 3 to 11 micron wavelength range. This new device (part number: P13894-011MA) extends the upper limit of sensitivity of Hamamatsu’s InAsSb detectors from 8 microns to 11 microns, which will enable users to measure molecules that absorb longer wavelengths of light and thus analyze more compounds with a single device.

  • Solar Simulation

    Sciencetech, Inc.

    Sciencetech solar simulators produce high intensity, uniform illumination on a target area. Typically, high power solar simulators use an ellipsoidal reflector to capture light from an arc lamp source inside the reflector, an arrangement that results in a light pattern with a bright outer region and a dark center. This non-uniformity is un- acceptable in many solar simulator applications and as a result, forces many of our solar simulator competitors to use designs involving diffusers to reduce the non-uniformity. This results in a reduction of intensity and a dis- tortion of the spectrum on the target area.

  • Vibration Analyzers/Balancers

    Balmac Inc.

    Vibration Analyzer with Strobe Light for vibration analysis and in-place dynamic balancing. These instruments are known for their rugged durability, reliable operation and accurate readings. The Tunable Filter and Strobe Light are a favorite with operators - easy to use and more convenient than digital filters and laser photo tachs. These analyzer/balancers allow operators to dynamically balance rotors of any size and shape.

  • Software

    WinWerth® 3D Module - Werth Inc.

    High Speed Measurement for Time Critical ApplicationsMeasurement of features during continuous movement of the measuring axesWorks with all three illumination options (back light, dark field and bright field light)Significant reduction of measuring time through the omission of Start – Stop cyclesAnalysis of recorded objects simultaneously with the movement to the next measuring locationIntelligent macro programming of repetitive tasks with identical lighting and magnification settings

  • Software

    OnTheFly® - Werth Inc.

    High Speed Measurement for Time Critical ApplicationsMeasurement of features during continuous movement of the measuring axesWorks with all three illumination options (back light, dark field and bright field light)Significant reduction of measuring time through the omission of Start – Stop cyclesAnalysis of recorded objects simultaneously with the movement to the next measuring locationIntelligent macro programming of repetitive tasks with identical lighting and magnification settings

  • Transmittance Dust Measuring Devices

    SICK Sensor Intelligence

    Maintaining a clear sightline even when dust concentrations are highTransmittance dust measuring devices transmit light through the entire duct. With this type of measurement, light attenuation indicates the concentration of dust inside the duct. These measuring devices are specially designed for medium to high dust concentrations and large duct diameters. Consequently, they are equally suited to emission and process monitoring as they are to hall monitoring applications.

  • TwinMate

    L-208 - Sekonic Corporation

    The Sekonic L-208 TwinMate is a palm-sized analog light meter for hand-held incident and reflected ambient light readings. It can also be mounted onto a camera or bracket using the included hot-shoe adapter for quick, camera-positioned reference readings. Though designed primarily for entry-level users, long-time shooters look to the Sekonic L-208 TwinMate as an accurate, easy-to-stow, back-up meter. Owners of rangefinder cameras who desire an incident and reflected meter also appreciate the included shoe mount.